Literature DB >> 23198398

A novel technique for intra-aortic balloon positioning in the intensive care unit.

Vijish Venugopal1.   

Abstract

Proper positioning of the intra-aortic balloon catheter is very important as an improperly placed balloon can cause problems. A balloon placed too high can block off the arch vessels, whereas one placed too low can block the renal and splanchnic vessels. We propose a simple and reliable technique to properly position the intra-aortic balloon pump (IABP) catheter without the use of any sophisticated or expensive equipment in the intensive care unit if the catheter has migrated from the previously placed desired position. In this technique, we rely on the left radial arterial trace obliteration as the IABP catheter is pushed in along a guidewire as a marker for tip positioning.

Entities:  

Mesh:

Year:  2012        PMID: 23198398      PMCID: PMC4557529     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  6 in total

Review 1.  Postoperative cardiopulmonary thoracic imaging.

Authors:  Anil Attili; Ella A Kazerooni
Journal:  Radiol Clin North Am       Date:  2004-05       Impact factor: 2.303

Review 2.  Nursing care of patients receiving: intra-aortic balloon counterpulsation.

Authors:  Mary Beth Reid; Damon Cottrell
Journal:  Crit Care Nurse       Date:  2005-10       Impact factor: 1.708

Review 3.  Basic principles of the intraaortic balloon pump and mechanisms affecting its performance.

Authors:  Theodoros G Papaioannou; Christodoulos Stefanadis
Journal:  ASAIO J       Date:  2005 May-Jun       Impact factor: 2.872

4.  The efficacy of the high volume counterpulsation technique at very low levels of aortic pressure.

Authors:  C E Charitos; J N Nanas; D A Kontoyiannis; S N Nanas; G Z Stamatopoulos; A C Rapti; S F Stamatelopoulos; S D Moulopoulos
Journal:  J Cardiovasc Surg (Torino)       Date:  1998-10       Impact factor: 1.888

Review 5.  Intraaortic counterpulsation balloon: radiographic considerations.

Authors:  E A Hyson; C E Ravin; M J Kelley; A M Curtis
Journal:  AJR Am J Roentgenol       Date:  1977-06       Impact factor: 3.959

6.  The carina as a useful radiographic landmark for positioning the intraaortic balloon pump.

Authors:  Jin-Tae Kim; Jeong-Rim Lee; Jae-Kwang Kim; Seung Zhoo Yoon; Yunseok Jeon; Jae-Hyon Bahk; Ki-Bong Kim; Chong-Sung Kim; Young-Jin Lim; Hee-Soo Kim; Seong-Deok Kim
Journal:  Anesth Analg       Date:  2007-09       Impact factor: 5.108

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.