Alternating current (AC) iontophoretic transport across human epidermal membrane: effects of AC frequency and amplitude.

Guang Yan1, Qingfang Xu, Yuri G Anissimov, Jinsong Hao, William I Higuchi, S Kevin Li.   

Abstract

PURPOSE: As a continuing effort to understand the mechanisms of alternating current (AC) transdermal iontophoresis and the iontophoretic transport pathways in the stratum corneum (SC), the objectives of the present study were to determine the interplay of AC frequency, AC voltage, and iontophoretic transport of ionic and neutral permeants across human epidermal membrane (HEM) and use AC as a means to characterize the transport pathways.
MATERIALS AND METHODS: Constant AC voltage iontophoresis experiments were conducted with HEM in 0.10 M tetraethyl ammonium pivalate (TEAP). AC frequencies ranging from 0.0001 to 25 Hz and AC applied voltages of 0.5 and 2.5 V were investigated. Tetraethyl ammonium (TEA) and arabinose (ARA) were the ionic and neutral model permeants, respectively. In data analysis, the logarithm of the permeability coefficients of HEM for the model permeants was plotted against the logarithm of the HEM electrical resistance for each AC condition.
RESULTS: As expected, linear correlations between the logarithms of permeability coefficients and the logarithms of resistances of HEM were observed, and the permeability data were first normalized and then compared at the same HEM electrical resistance using these correlations. Transport enhancement of the ionic permeant was significantly larger than that of the neutral permeant during AC iontophoresis. The fluxes of the ionic permeant during AC iontophoresis of 2.5 V in the frequency range from 5 to 1,000 Hz were relatively constant and were approximately 4 times over those of passive transport. When the AC frequency decreased from 5 to 0.001 Hz at 2.5 V, flux enhancement increased to around 50 times over passive transport.
CONCLUSION: While the AC frequency for achieving the full effect of iontophoretic enhancement at low AC frequency was lower than anticipated, the frequency for approaching passive diffusion transport at high frequency was higher than expected from the HEM morphology. These observations are consistent with a transport model of multiple barriers in series and the previous hypothesis that the iontophoresis pathways across HEM under AC behave like a series of reservoirs interconnected by short pore pathways.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17703345      PMCID: PMC2556247          DOI: 10.1007/s11095-007-9405-2

Source DB:  PubMed          Journal:  Pharm Res        ISSN: 0724-8741            Impact factor:   4.200


  22 in total

1.  Hydration disrupts human stratum corneum ultrastructure.

Authors:  Ronald R Warner; Keith J Stone; Ying L Boissy
Journal:  J Invest Dermatol       Date:  2003-02       Impact factor: 8.551

2.  Lidocaine transport through living rat skin using alternating current.

Authors:  H Haga; T Shibaji; M Umino
Journal:  Med Biol Eng Comput       Date:  2005-09       Impact factor: 2.602

3.  Hindered diffusion of polar molecules through and effective pore radii estimates of intact and ethanol treated human epidermal membrane.

Authors:  K D Peck; A H Ghanem; W I Higuchi
Journal:  Pharm Res       Date:  1994-09       Impact factor: 4.200

4.  Studies on the effects of applied voltage and duration on human epidermal membrane alteration/recovery and the resultant effects upon iontophoresis.

Authors:  H Inada; A H Ghanem; W I Higuchi
Journal:  Pharm Res       Date:  1994-05       Impact factor: 4.200

5.  Quantification of pore induction in human epidermal membrane during iontophoresis: the importance of background electrolyte selection.

Authors:  H Zhu; K D Peck; S K Li; A H Ghanem; W I Higuchi
Journal:  J Pharm Sci       Date:  2001-07       Impact factor: 3.534

Review 6.  Glucose monitoring by reverse iontophoresis.

Authors:  Russell O Potts; Janet A Tamada; Michael J Tierney
Journal:  Diabetes Metab Res Rev       Date:  2002 Jan-Feb       Impact factor: 4.876

7.  Transdermal delivery of lidocaine in vitro by alternating current.

Authors:  Tatsuki Kinoshita; Takao Shibaji; Masahiro Umino
Journal:  J Med Dent Sci       Date:  2003-03

8.  Improvement on conventional constant current DC iontophoresis: a study using constant conductance AC iontophoresis.

Authors:  Honggang Zhu; S Kevin Li; Kendall D Peck; David J Miller; William I Higuchi
Journal:  J Control Release       Date:  2002-08-21       Impact factor: 9.776

9.  In vitro and in vivo comparisons of constant resistance AC iontophoresis and DC iontophoresis.

Authors:  S Kevin Li; William I Higuchi; Honggang Zhu; Steven E Kern; David J Miller; Matthew S Hastings
Journal:  J Control Release       Date:  2003-09-04       Impact factor: 9.776

10.  Investigation of properties of human epidermal membrane under constant conductance alternating current iontophoresis.

Authors:  Honggang Zhu; Kendall D Peck; David J Miller; Mark R Liddell; Guang Yan; William I Higuchi; S Kevin Li
Journal:  J Control Release       Date:  2003-04-14       Impact factor: 9.776

View more
  2 in total

1.  Evaluation of diclofenac prodrugs for enhancing transdermal delivery.

Authors:  Shabbir Lobo; Henan Li; Nashid Farhan; Guang Yan
Journal:  Drug Dev Ind Pharm       Date:  2013-04-23       Impact factor: 3.225

2.  Effects of alternating current frequency and permeation enhancers upon human epidermal membrane.

Authors:  Qingfang Xu; Rajan P Kochambilli; Yang Song; Jinsong Hao; William I Higuchi; S Kevin Li
Journal:  Int J Pharm       Date:  2009-01-04       Impact factor: 5.875