Literature DB >> 12932711

In vitro and in vivo comparisons of constant resistance AC iontophoresis and DC iontophoresis.

S Kevin Li1, William I Higuchi, Honggang Zhu, Steven E Kern, David J Miller, Matthew S Hastings.   

Abstract

A previous in vitro constant electrical resistance alternating current (AC) iontophoresis study with human epidermal membrane (HEM) and a model neutral permeant has shown less inter- and intra-sample variability in iontophoretic transport relative to conventional constant direct current (DC) iontophoresis. The objectives of the present study were to address the following questions. (1) Can the skin electrical resistance be maintained at a constant level by AC in humans in vivo? (2) Are the in vitro data with HEM representative of those in vivo? (3) Does constant skin resistance AC iontophoresis have less inter- and intra-sample variability than conventional constant current DC iontophoresis in vivo? (4) What are the electrical and the barrier properties of skin during iontophoresis in vivo? In the present study, in vitro HEM experiments were carried out with the constant resistance AC and the conventional constant current DC methods using mannitol and glucose as the neutral model permeants. In vivo human experiments were performed using glucose as the permeant with a constant skin resistance AC only protocol and two conventional constant current DC methods (continuous constant current DC and constant current DC with its polarity alternated every 10 min with a 3:7 on:off duty cycle). Constant current DC iontophoresis was conducted with commercial constant current DC devices, and constant resistance AC iontophoresis was carried out by reducing and maintaining the skin resistance at a constant target value with AC supplied from a function generator. This study shows that (1) skin electrical resistance can be maintained at a constant level during AC iontophoresis in vivo; (2) HEM in vitro and human skin in vivo demonstrate similar electrical and barrier properties, and these properties are consistent with our previous findings; (3) there is general qualitative and semi-quantitative agreement between the HEM data in vitro and human skin data in vivo; and (4) constant skin resistance AC iontophoresis generally provides less inter- and intra-subject variability than conventional constant current DC.

Entities:  

Mesh:

Year:  2003        PMID: 12932711     DOI: 10.1016/s0168-3659(03)00268-2

Source DB:  PubMed          Journal:  J Control Release        ISSN: 0168-3659            Impact factor:   9.776


  8 in total

1.  Modeling iontophoretic drug delivery in a microfluidic device.

Authors:  Maryam Moarefian; Rafael V Davalos; Danesh K Tafti; Luke E Achenie; Caroline N Jones
Journal:  Lab Chip       Date:  2020-09-01       Impact factor: 6.799

2.  Ion-exchange membrane assisted transdermal iontophoretic delivery of salicylate and acyclovir.

Authors:  Qingfang Xu; Sarah A Ibrahim; William I Higuchi; S Kevin Li
Journal:  Int J Pharm       Date:  2008-11-11       Impact factor: 5.875

3.  Noninvasive measurement of phenylalanine by iontophoretic extraction in patients with phenylketonuria.

Authors:  N Longo; S K Li; G Yan; R P Kochambilli; K Papangkorn; D Berglund; A-H Ghanem; C L Ashurst; S L Ernst; M Pasquali; W I Higuchi
Journal:  J Inherit Metab Dis       Date:  2007-10-05       Impact factor: 4.982

4.  Alternating current (AC) iontophoretic transport across human epidermal membrane: effects of AC frequency and amplitude.

Authors:  Guang Yan; Qingfang Xu; Yuri G Anissimov; Jinsong Hao; William I Higuchi; S Kevin Li
Journal:  Pharm Res       Date:  2007-08-17       Impact factor: 4.200

5.  Time-dependent electrical properties of human nail upon hydration in vivo.

Authors:  Jinsong Hao; Kelly A Smith; S Kevin Li
Journal:  J Pharm Sci       Date:  2010-01       Impact factor: 3.534

6.  Effects of alternating current frequency and permeation enhancers upon human epidermal membrane.

Authors:  Qingfang Xu; Rajan P Kochambilli; Yang Song; Jinsong Hao; William I Higuchi; S Kevin Li
Journal:  Int J Pharm       Date:  2009-01-04       Impact factor: 5.875

7.  A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring.

Authors:  Zhihua Pu; Xingguo Zhang; Haixia Yu; Jiaan Tu; Hailong Chen; Yuncong Liu; Xiao Su; Ridong Wang; Lei Zhang; Dachao Li
Journal:  Sci Adv       Date:  2021-01-27       Impact factor: 14.136

8.  Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test.

Authors:  Carla Cristina Souza Gomez; Maria de Fatima Servidoni; Fernando Augusto de Lima Marson; Paulo Jose Coelho Canavezi; Adriana Mendes Vinagre; Eduardo Tavares Costa; Antonio Fernando Ribeiro; Maria Angela Gonçalves de Oliveira Ribeiro; Adyleia Aparecida Dalbo Contrera Toro; Celia Regina Pavan; Michelle Vivine Sá Dos Santos Rondon; Sonia Leticia Silva Lorena; Francisco Ubaldi Vieria; Jose Dirceu Ribeiro
Journal:  BMC Pulm Med       Date:  2014-12-13       Impact factor: 3.317

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.