Literature DB >> 12175741

Improvement on conventional constant current DC iontophoresis: a study using constant conductance AC iontophoresis.

Honggang Zhu1, S Kevin Li, Kendall D Peck, David J Miller, William I Higuchi.   

Abstract

The purpose of the present study was to compare conventional constant direct current (DC) transdermal iontophoresis with a new constant conductance alternating current (AC) iontophoresis method. The new method was developed with the intent of reducing flux drift during iontophoresis and minimizing skin-to-skin variability. The constant conductance AC iontophoresis studies involved three electrical components: (1) an initial applied potential used to decrease the human epidermal membrane (HEM) electrical resistance to a target level of either 1.5 or 3.0 k Omega cm(2), (2) an applied 50 Hz square-wave AC with a variable potential adjusted to maintain the HEM conductance at the target level during the transport study, and (3) a low voltage DC offset of 0 (passive), 0.25, or 0.40 V applied simultaneously with the AC to assist permeant transport. Current densities of 0.13 and 0.26 mA/cm(2) were chosen for the conventional constant current DC iontophoresis studies. Mannitol was used as the probe permeant for all studies. The constant current DC studies showed significant increases in mannitol flux with time during a given experiment and large skin-to-skin variability. Compared to the constant current DC experiments, the mannitol flux remained more constant during the constant conductance AC iontophoresis and skin-to-skin variability was significantly reduced. On a mechanistic level, changes in the transport properties during constant current DC iontophoresis indicate changes in the membrane parameters such as porosity, effective pore size, and/or pore surface charge density during the conventional method of iontophoresis. The results from the constant conductance AC iontophoresis transport studies imply that this method effectively maintains the membrane parameters that affect transport at a constant state this providing for a relatively constant permanent flux.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12175741     DOI: 10.1016/s0168-3659(02)00107-4

Source DB:  PubMed          Journal:  J Control Release        ISSN: 0168-3659            Impact factor:   9.776


  3 in total

1.  Alternating current (AC) iontophoretic transport across human epidermal membrane: effects of AC frequency and amplitude.

Authors:  Guang Yan; Qingfang Xu; Yuri G Anissimov; Jinsong Hao; William I Higuchi; S Kevin Li
Journal:  Pharm Res       Date:  2007-08-17       Impact factor: 4.200

2.  Effects of alternating current frequency and permeation enhancers upon human epidermal membrane.

Authors:  Qingfang Xu; Rajan P Kochambilli; Yang Song; Jinsong Hao; William I Higuchi; S Kevin Li
Journal:  Int J Pharm       Date:  2009-01-04       Impact factor: 5.875

Review 3.  Selected Medicines Used in Iontophoresis.

Authors:  Tomasz M Karpiński
Journal:  Pharmaceutics       Date:  2018-10-25       Impact factor: 6.321

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.