Literature DB >> 17698231

Accuracy of volume and DVH parameters determined with different brachytherapy treatment planning systems.

Christian Kirisits1, Frank-André Siebert, Dimos Baltas, Marisol De Brabandere, Taran Paulsen Hellebust, Daniel Berger, Jack Venselaar.   

Abstract

PURPOSE: To determine the uncertainties in dose volume histogram (DVH) analysis used in modern brachytherapy treatment planning systems (TPSs).
MATERIALS AND METHODS: A phantom with three different volumes was scanned with CT and MRI. An inter-observer analysis was based on contouring performed by 5 persons. The volume of a standard contour set was calculated using seven different TPSs. For five systems a typical brachytherapy dose distribution was used to compare DVH determination.
RESULTS: The inter-observer variability (1SD) was 13% for a small cylindrical volume, 5% for a large cylinder and 3% for a conical shape. A standardized volume for a 4mm CT scan contoured on seven different TPS varied by 7%, 2%, and 5% (1SD). Use of smaller slice thickness reduced the variations. A treatment plan with the sources between the large cylindrical shape and the cone showed variations for D(2cc) of 1% and 5% (1SD), respectively. Deviations larger than 10% were observed for a smaller source to cylinder surface distance of 5mm.
CONCLUSIONS: Modern TPSs minimize the volumetric and dosimetric calculation uncertainties. These are comparable to inter-observer contouring variations. However, differences in volume result from the methods of calculation in the first and last slice of a contoured structure. For this situation and in case of high dose gradients inside analyzed volumes, high uncertainties were observed. The use of DVH parameters in clinical practice should take into account the method of calculation and the possible uncertainties.

Entities:  

Mesh:

Year:  2007        PMID: 17698231     DOI: 10.1016/j.radonc.2007.06.010

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  11 in total

Review 1.  In vivo dosimetry: trends and prospects for brachytherapy.

Authors:  G Kertzscher; A Rosenfeld; S Beddar; K Tanderup; J E Cygler
Journal:  Br J Radiol       Date:  2014-07-08       Impact factor: 3.039

2.  Dependence of volume calculation and margin growth accuracy on treatment planning systems for stereotactic radiosurgery.

Authors:  David J Eaton; Kevin Alty
Journal:  Br J Radiol       Date:  2017-10-12       Impact factor: 3.039

3.  AAPM recommendations on dose prescription and reporting methods for permanent interstitial brachytherapy for prostate cancer: report of Task Group 137.

Authors:  Ravinder Nath; William S Bice; Wayne M Butler; Zhe Chen; Ali S Meigooni; Vrinda Narayana; Mark J Rivard; Yan Yu
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

4.  Influence of image slice thickness on rectal dose-response relationships following radiotherapy of prostate cancer.

Authors:  C Olsson; M Thor; M Liu; V Moissenko; S E Petersen; M Høyer; A Apte; J O Deasy
Journal:  Phys Med Biol       Date:  2014-06-17       Impact factor: 3.609

5.  Commissioning of brachytherapy module of Oncentra MasterPlan treatment planning system.

Authors:  Carla Alves de Oliveira; Maria do Carmo Lopes; Armanda Matos
Journal:  J Contemp Brachytherapy       Date:  2010-01-13

6.  Correlation between treatment plan parameters and particular prognostic factors in prostate cancer treated with high-dose-rate brachytherapy (HDR-BT) as a boost.

Authors:  Adam Chicheł; Marek Kanikowski; Janusz Skowronek; Magdalena Dymnicka; Tomasz Piotrowski
Journal:  J Contemp Brachytherapy       Date:  2009-03-23

7.  Impact of different Ir-192 source models on dose calculations in high-dose-rate brachytherapy.

Authors:  Yuki Otani; Shigetoshi Shimamoto; Iori Sumida; Yutaka Takahashi; Shoji Tani; Tetsuya Oshima; Satoshi Onosaka; Fumiaki Isohashi; Keisuke Tamari; Kazuhiko Ogawa
Journal:  Phys Imaging Radiat Oncol       Date:  2018-08-31

8.  Head and neck (192)Ir HDR-brachytherapy dosimetry using a grid-based Boltzmann solver.

Authors:  Frank-André Siebert; Sabine Wolf; George Kóvacs
Journal:  J Contemp Brachytherapy       Date:  2013-12-18

Review 9.  Review of clinical brachytherapy uncertainties: analysis guidelines of GEC-ESTRO and the AAPM.

Authors:  Christian Kirisits; Mark J Rivard; Dimos Baltas; Facundo Ballester; Marisol De Brabandere; Rob van der Laarse; Yury Niatsetski; Panagiotis Papagiannis; Taran Paulsen Hellebust; Jose Perez-Calatayud; Kari Tanderup; Jack L M Venselaar; Frank-André Siebert
Journal:  Radiother Oncol       Date:  2013-11-30       Impact factor: 6.280

10.  Accuracy evaluation of a 3D-printed individual template for needle guidance in head and neck brachytherapy.

Authors:  Ming-Wei Huang; Jian-Guo Zhang; Lei Zheng; Shu-Ming Liu; Guang-Yan Yu
Journal:  J Radiat Res       Date:  2016-07-15       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.