Literature DB >> 17690983

The effect of regional variations of the trabecular bone properties on the compressive strength of human vertebral bodies.

Do-Gyoon Kim1, Christine A Hunt, Roger Zauel, David P Fyhrie, Yener N Yeni.   

Abstract

Cancellous centrum is a major component of the vertebral body and significantly contributes to its structural strength and fracture risk. We hypothesized that the variability of cancellous bone properties in the centrum is associated with vertebral strength. Microcomputed tomography (micro-CT)-based gray level density (GLD), bone volume fraction (BV/TV), and finite element modulus (E) were examined for different regions of the trabecular centrum and correlated with vertebral body strength determined experimentally. Two sets of images in the cancellous centrum were digitally prepared from micro-CT images of eight human vertebral bodies (T10-L5). One set included a cubic volume (1 per vertebral centrum, n = 8) in which the largest amount of cancellous material from the centrum was included but all the shell materials were excluded. The other set included cylindrical volumes (6 per vertebral centrum, n = 48) from the anterior (4 regions: front, center, left, and right of the midline of vertebra) and the posterior (2 regions: left and right) regions of the centrum. Significant positive correlations of vertebral strength with GLD (r (2) = 0.57, p = 0.03) and E (r (2) = 0.63, p = 0.02) of the whole centrum and with GLD (r (2) = 0.65, p = 0.02), BV/TV (r (2) = 0.72, p = 0.01) and E (r (2) = 0.85, p = 0.001) of the central region of the vertebral centrum were found. Vertebral strength decreased with increasing coefficient of variation of GLD, BV/TV, and E calculated from subregions of the vertebral centrum. The values of GLD, BV/TV, and E in centrum were significantly smaller for the anterior region than for the posterior region. Overall, these findings supported the significant role of regional variability of centrum properties in determining the whole vertebral strength.

Entities:  

Mesh:

Year:  2007        PMID: 17690983     DOI: 10.1007/s10439-007-9363-1

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  21 in total

1.  Measurement of subregional vertebral bone mineral density in vitro using lateral projection dual-energy X-ray absorptiometry: validation with peripheral quantitative computed tomography.

Authors:  Andrew M Briggs; Egon Perilli; Ian H Parkinson; Susan Kantor; Tim V Wrigley; Nicola L Fazzalari; John D Wark
Journal:  J Bone Miner Metab       Date:  2011-09-13       Impact factor: 2.626

2.  Association of vertebral endplate microstructure with bone strength in men and women.

Authors:  MeiLissa McKay; Timothy M Jackman; Amira I Hussein; Ali Guermazi; Jingjiang Liu; Elise F Morgan
Journal:  Bone       Date:  2019-11-06       Impact factor: 4.398

3.  Modic (endplate) changes in the lumbar spine: bone micro-architecture and remodelling.

Authors:  Egon Perilli; Ian H Parkinson; Le-Hoa Truong; Kuan C Chong; Nicola L Fazzalari; Orso L Osti
Journal:  Eur Spine J       Date:  2014-07-26       Impact factor: 3.134

4.  Principal trabecular structural orientation predicted by quantitative ultrasound is strongly correlated with μFEA determined anisotropic apparent stiffness.

Authors:  Liangjun Lin; Han Yuen Oon; Wei Lin; Yi-Xian Qin
Journal:  Biomech Model Mechanobiol       Date:  2014-01-14

5.  Influence of the shape of the micro-finite element model on the mechanical properties calculated from micro-finite element analysis.

Authors:  Xin-Xin Wen; Hai-Long Yu; Ya-Bo Yan; Chun-Lin Zong; Hai-Jiao Ding; Xiang-Yu Ma; Tian-Sheng Wang; Wei Lei
Journal:  Exp Ther Med       Date:  2017-06-28       Impact factor: 2.447

6.  The effect of intravertebral heterogeneity in microstructure on vertebral strength and failure patterns.

Authors:  A I Hussein; E F Morgan
Journal:  Osteoporos Int       Date:  2012-06-16       Impact factor: 4.507

7.  Variability of trabecular microstructure is age-, gender-, race- and anatomic site-dependent and affects stiffness and stress distribution properties of human vertebral cancellous bone.

Authors:  Yener N Yeni; Matthew J Zinno; Janardhan S Yerramshetty; Roger Zauel; David P Fyhrie
Journal:  Bone       Date:  2011-07-19       Impact factor: 4.398

8.  Heterogeneity of bone mineral density and fatigue failure of human vertebrae.

Authors:  Yener N Yeni; Laila M Poisson; Michael J Flynn
Journal:  J Biomech       Date:  2013-03-26       Impact factor: 2.712

9.  Presence of intervertebral discs alters observed stiffness and failure mechanisms in the vertebra.

Authors:  Amira I Hussein; Zachary D Mason; Elise F Morgan
Journal:  J Biomech       Date:  2013-05-14       Impact factor: 2.712

10.  The intravertebral distribution of bone density: correspondence to intervertebral disc health and implications for vertebral strength.

Authors:  A I Hussein; T M Jackman; S R Morgan; G D Barest; E F Morgan
Journal:  Osteoporos Int       Date:  2013-07-18       Impact factor: 4.507