Literature DB >> 17689767

Effects of simultaneous EEG recording on MRI data quality at 1.5, 3 and 7 tesla.

Karen Mullinger1, Stefan Debener, Ronald Coxon, Richard Bowtell.   

Abstract

Although the focus of attention on data degradation during simultaneous MRI/EEG recording has to date largely been upon EEG artefacts, the presence of the conducting wires and electrodes of the EEG recording system also causes some degradation of MRI data quality. This may result from magnetic susceptibility effects which lead to signal drop-out and image distortion, as well as the perturbation of the radiofrequency fields, which can cause local signal changes and a global reduction in the signal to noise ratio (SNR) of magnetic resonance images. Here, we quantify the effect of commercially available 32 and 64 electrode caps on the quality of MR images obtained in scanners operating at magnetic fields of 1.5, 3 and 7 T, via the use of MR-based, field-mapping techniques and analysis of the SNR in echo planar image time series. The electrodes are shown to be the dominant source of magnetic field inhomogeneity, although the localised nature of the field perturbation that they produce means that the effect on the signal intensity from the brain is not significant. In the particular EEG caps investigated here, RF inhomogeneity linked to the longer ECG and EOG leads causes some reduction in the signal intensity in images obtained at 3 and 7 T. Measurements of the standard deviation of white matter signal in EPI time series indicates that the introduction of the EEG cap produces a small reduction in the image signal to noise ratio, which increases with the number of electrodes used.

Entities:  

Mesh:

Year:  2007        PMID: 17689767     DOI: 10.1016/j.ijpsycho.2007.06.008

Source DB:  PubMed          Journal:  Int J Psychophysiol        ISSN: 0167-8760            Impact factor:   2.997


  19 in total

1.  Influence of dense-array EEG cap on fMRI signal.

Authors:  Qingfei Luo; Gary H Glover
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  The utility of conductive plastic electrodes in prolonged ICU EEG monitoring.

Authors:  Rohit R Das; Brendan P Lucey; Sherry H-Y Chou; Patricio S Espinosa; Amir A Zamani; Barbara A Dworetzky; Edward B Bromfield; Jong Woo Lee
Journal:  Neurocrit Care       Date:  2008-09-20       Impact factor: 3.210

3.  Coupling electrophysiological and hemodynamic responses to errors.

Authors:  Nuria Doñamayor; Urs Heilbronner; Thomas F Münte
Journal:  Hum Brain Mapp       Date:  2011-05-26       Impact factor: 5.038

4.  On the feasibility of concurrent human TMS-EEG-fMRI measurements.

Authors:  Judith C Peters; Joel Reithler; Teresa Schuhmann; Tom de Graaf; Kâmil Uludag; Rainer Goebel; Alexander T Sack
Journal:  J Neurophysiol       Date:  2012-12-05       Impact factor: 2.714

5.  Data quality in fMRI and simultaneous EEG-fMRI.

Authors:  Toni Ihalainen; Linda Kuusela; Sampsa Turunen; Sami Heikkinen; Sauli Savolainen; Outi Sipilä
Journal:  MAGMA       Date:  2014-04-26       Impact factor: 2.310

6.  Computational electromagnetic analysis in a human head model with EEG electrodes and leads exposed to RF-field sources at 915 MHz and 1748 MHz.

Authors:  Leonardo M Angelone; Giorgi Bit-Babik; Chung-Kwang Chou
Journal:  Radiat Res       Date:  2010-07       Impact factor: 2.841

7.  Exploring the advantages of multiband fMRI with simultaneous EEG to investigate coupling between gamma frequency neural activity and the BOLD response in humans.

Authors:  Makoto Uji; Ross Wilson; Susan T Francis; Karen J Mullinger; Stephen D Mayhew
Journal:  Hum Brain Mapp       Date:  2018-01-13       Impact factor: 5.038

8.  Polymer thick film technology for improved simultaneous dEEG/MRI recording: Safety and MRI data quality.

Authors:  Catherine Poulsen; Daniel G Wakeman; Seyed Reza Atefi; Phan Luu; Amy Konyn; Giorgio Bonmassar
Journal:  Magn Reson Med       Date:  2016-02-15       Impact factor: 4.668

9.  Presurgical brain mapping in epilepsy using simultaneous EEG and functional MRI at ultra-high field: feasibility and first results.

Authors:  Frédéric Grouiller; João Jorge; Francesca Pittau; Wietske van der Zwaag; Giannina Rita Iannotti; Christoph Martin Michel; Serge Vulliémoz; Maria Isabel Vargas; François Lazeyras
Journal:  MAGMA       Date:  2016-03-05       Impact factor: 2.310

Review 10.  Physiological recordings: basic concepts and implementation during functional magnetic resonance imaging.

Authors:  Marcus A Gray; Ludovico Minati; Neil A Harrison; Peter J Gianaros; Vitaly Napadow; Hugo D Critchley
Journal:  Neuroimage       Date:  2009-05-19       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.