Literature DB >> 17684075

Precision of computer-aided volumetry of artificial small solid pulmonary nodules in ex vivo porcine lungs.

H Bolte1, C Riedel, C Riede, S Müller-Hülsbeck, S Freitag-Wolf, G Kohl, T Drews, M Heller, J Biederer, J Bieder.   

Abstract

The purpose of this study was to investigate the precision of CT-based volumetric measurements of artificial small pulmonary nodules under ex vivo conditions. We implanted 322 artificial nodules in 23 inflated ex vivo porcine lungs in a dedicated chest phantom. The lungs were examined with a multislice spiral CT (20 mAs, collimation 16x0.75 mm, 1 mm slice thickness, 0.7 mm increment). A commercial volumetry software package (LungCARE VA70C-W; Siemens, Erlangen, Germany) was used for volume analysis in a semi-automatic and a manual corrected mode. After imaging, the lungs were dissected to harvest the nodules for gold standard determination. The volumes of 202 solitary, solid and well-defined lesions without contact with the pleura, greater bronchi or vessels were compared with the results of volumetry. A mean nodule diameter of 8.3 mm (+/-2.1 mm) was achieved. The mean relative deviation from the true lesion volume was -9.2% (+/-10.6%) for semi-automatic and -0.3% (+/-6.5%) for manual corrected volumetry. The subgroup of lesions from 5 mm to <10 mm in diameter showed a mean relative deviation of -8.7% (+/-10.9%) for semi-automatic volumetry and -0.3% (+/-6.9%) for manually corrected volumetry. We conclude that the presented software allowed for precise volumetry of artificial nodules in ex vivo lung tissue. This result is comparable to the findings of previous in vitro studies.

Mesh:

Year:  2007        PMID: 17684075     DOI: 10.1259/bjr/23933268

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

1.  Semi-automated volumetric analysis of lymph node metastases during follow-up--initial results.

Authors:  Michael Fabel; H Bolte; H von Tengg-Kobligk; L Bornemann; V Dicken; S Delorme; H-U Kauczor; M Heller; J Biederer
Journal:  Eur Radiol       Date:  2010-10-17       Impact factor: 5.315

2.  Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT: an anthropomorphic phantom study.

Authors:  X Xie; M J Willemink; Y Zhao; P A de Jong; P M A van Ooijen; M Oudkerk; M J W Greuter; R Vliegenthart
Journal:  Br J Radiol       Date:  2013-07-24       Impact factor: 3.039

3.  Inter-Method Performance Study of Tumor Volumetry Assessment on Computed Tomography Test-Retest Data.

Authors:  Andrew J Buckler; Jovanna Danagoulian; Kjell Johnson; Adele Peskin; Marios A Gavrielides; Nicholas Petrick; Nancy A Obuchowski; Hubert Beaumont; Lubomir Hadjiiski; Rudresh Jarecha; Jan-Martin Kuhnigk; Ninad Mantri; Michael McNitt-Gray; Jan H Moltz; Gergely Nyiri; Sam Peterson; Pierre Tervé; Christian Tietjen; Etienne von Lavante; Xiaonan Ma; Samantha St Pierre; Maria Athelogou
Journal:  Acad Radiol       Date:  2015-09-14       Impact factor: 3.173

4.  Pulmonary Nodules: growth rate assessment in patients by using serial CT and three-dimensional volumetry.

Authors:  Jane P Ko; Erika J Berman; Manmeen Kaur; James S Babb; Elan Bomsztyk; Alissa K Greenberg; David P Naidich; Henry Rusinek
Journal:  Radiology       Date:  2011-12-09       Impact factor: 11.105

Review 5.  Volumetric analysis at abdominal CT: oncologic and non-oncologic applications.

Authors:  Virginia B Planz; Meghan G Lubner; Perry J Pickhardt
Journal:  Br J Radiol       Date:  2018-11-30       Impact factor: 3.039

Review 6.  [Cellular mechanisms of tumor response: clinical demands].

Authors:  M-K Ganten; M A Weber; T M Ganten
Journal:  Radiologe       Date:  2008-09       Impact factor: 0.635

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.