Literature DB >> 33262875

Long-term fracture load of all-ceramic crowns: Effects of veneering ceramic thickness, application techniques, and cooling protocol.

Júlia-Magalhães-da Costa Lima1, João-Paulo-Mendes Tribst2, Lilian-Costa Anami3, Renata-Marques de Melo2, Dayanne-Monielle-Duarte Moura4, Rodrigo-Othávio-Assunção Souza4, Marco-Antonio Bottino2.   

Abstract

BACKGROUND: To evaluate, in vitro, the effects of the cooling protocol, application technique, and veneering ceramic thickness on the fracture resistance of ceramic crowns with Y-TZP frameworks.
MATERIAL AND METHODS: 80 frameworks were made from zirconia by the CAD/CAM technique and divided into 8 groups (n = 10) according to the factors: "application technique" (stratified-L and pressed -P), "thickness" (1 mm and 2 mm), and "cooling protocol" (slow-S and fast-F) of the feldspathic veneering ceramic. After, all crowns were cemented over G10 preparations with resin cement (Panavia F, Kuraray), mechanically cycled (2x106 cycles, 200 N, 3Hz), and subjected to the axial compression resistance test (0.5 mm/min, 10 kN). The data (N) underwent descriptive statistical analysis by 3-way ANOVA and Tukey's test (5%). Fracture analysis was performed to determine the possible origin of failure.
RESULTS: The factors "cooling protocol" (P=0.0058) and "application" technique (P=0.0001) influenced the fracture resistance of the crowns. For pressed veneer technique, the P2S (4608.9±464.5). A presented significantly higher results than that P2F(3621.1±523.0)BCD (Tukey's test). For the stratified technique, this difference was not observed (P>0.05). The thickness of the veneering ceramic was not significant regardless of the cooling protocol and technique (P>0.05). The predominant failure mode was chipping of the ceramic veneer originating in the subsurface.
CONCLUSIONS: The pressed technique, used with a slow-cooling protocol, leads to the best outcome for the veneering of all-ceramic crowns. Key words:Zirconia, ceramics, cooling protocol, thickness, application technique. Copyright:
© 2020 Medicina Oral S.L.

Entities:  

Year:  2020        PMID: 33262875      PMCID: PMC7680567          DOI: 10.4317/jced.57352

Source DB:  PubMed          Journal:  J Clin Exp Dent        ISSN: 1989-5488


  37 in total

1.  Fracture strength of yttria-stabilized tetragonal zirconia polycrystals crowns with different design: an in vitro study.

Authors:  Christel Larsson; Sammah El Madhoun; Ann Wennerberg; Per Vult von Steyern
Journal:  Clin Oral Implants Res       Date:  2011-06-02       Impact factor: 5.977

2.  Viscoelastic finite element evaluation of transient and residual stresses in dental crowns: Design parametric study.

Authors:  Sukirti Dhital; Camila Rodrigues; Yu Zhang; Jeongho Kim
Journal:  J Mech Behav Biomed Mater       Date:  2019-11-19

3.  Bite forces and their resultants during forceful intercuspal clenching in humans.

Authors:  Yoshinori Hattori; Chiaki Satoh; Takeyasu Kunieda; Rui Endoh; Hisayuki Hisamatsu; Makoto Watanabe
Journal:  J Biomech       Date:  2009-05-15       Impact factor: 2.712

4.  Influence of residual thermal stresses on the edge chipping resistance of PFM and veneered zirconia structures: Experimental and FEA study.

Authors:  Carina B Tanaka; Rafael Y Ballester; Grace M De Souza; Yu Zhang; Josete B C Meira
Journal:  Dent Mater       Date:  2018-12-20       Impact factor: 5.304

5.  Meta-analysis of fixed partial denture survival: prostheses and abutments.

Authors:  M S Scurria; J D Bader; D A Shugars
Journal:  J Prosthet Dent       Date:  1998-04       Impact factor: 3.426

6.  Thermal induced deflection of a porcelain-zirconia bilayer: Influence of cooling rate.

Authors:  M V Swain; V Mercurio; J E Tibballs; M Tholey
Journal:  Dent Mater       Date:  2019-02-07       Impact factor: 5.304

7.  Fracture performance of computer-aided manufactured zirconia and alloy crowns.

Authors:  Martin Rosentritt; Michael Behr; Christian Thaller; Heike Rudolph; Albert Feilzer
Journal:  Quintessence Int       Date:  2009-09       Impact factor: 1.677

8.  Fatigue and fracture properties of yttria partially stabilized zirconia crown systems.

Authors:  Eleftheria Tsalouchou; Mike J Cattell; Jonathan C Knowles; Piyapanna Pittayachawan; Ailbhe McDonald
Journal:  Dent Mater       Date:  2007-08-06       Impact factor: 5.304

9.  Fracture Resistance of Monolithic Zirconia Crowns in Implant Prostheses in Patients with Bruxism.

Authors:  Ting-Hsun Lan; Chin-Yun Pan; Pao-Hsin Liu; Mitch M C Chou
Journal:  Materials (Basel)       Date:  2019-05-17       Impact factor: 3.623

10.  Influence of substrate design for in vitro mechanical testing.

Authors:  Amanda-Maria-de Oliveira Dal Piva; João-Paulo-Mendes Tribst; Alexandre-Luiz-Souto Borges; Renata-Marques de Melo; Marco-Antonio Bottino
Journal:  J Clin Exp Dent       Date:  2019-02-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.