Literature DB >> 17681216

Repair of patellar tendon rupture with suture anchors.

David Capiola1, Louis Re.   

Abstract

Repair of a ruptured patellar tendon is usually performed with the use of sutures that are passed through intraosseous tunnels within the patella. However, a number of caveats pertain to this method. The Beath pin may penetrate the articular surface or may unduly injure the quadriceps through multiple passes. The already injured patellar tendon may be overly shortened after debridement and insertion into bony tunnels, and loosening through the tunnels may occur. Obliquely oriented bony tunnels may cause abnormal patellar tilt, leading to uneven force distribution. This technical note reports the details of an alternative repair with 3 suture anchors that is incorporated into a 6-stranded Krackow technique, with additional mattress sutures as needed. Because of the low-profile nature of the anchors, this technique more accurately re-creates the footprint at the inferior pole of the patella and avoids articular cartilage penetration and injury to the surrounding soft tissue. The possibility of loosening through bony tunnels or creation of abnormal stresses is eliminated. A smaller incision is used, and operative (tourniquet) time is diminished. Although pullout of the anchors may be a logical concern, previous studies have suggested that this construct is more than sufficient to withstand the forces to which it is subjected.

Entities:  

Mesh:

Year:  2007        PMID: 17681216     DOI: 10.1016/j.arthro.2006.10.023

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  12 in total

1.  Biomechanical evaluation of different surgical techniques for treating patellar tendon ruptures.

Authors:  Benedikt Schliemann; Niklas Grüneweller; Daiwei Yao; Clemens Kösters; Simon Lenschow; Steffen B Roßlenbroich; Michael J Raschke; Andre Weimann
Journal:  Int Orthop       Date:  2015-10-03       Impact factor: 3.075

2.  The effect of the trabecular microstructure on the pullout strength of suture anchors.

Authors:  Christopher M Yakacki; Mariya Poukalova; Robert E Guldberg; Angela Lin; Minn Saing; Scott Gillogly; Ken Gall
Journal:  J Biomech       Date:  2010-04-18       Impact factor: 2.712

3.  Bilateral Quadriceps Tendon Repair with Suture Anchors: Case Series.

Authors:  Jason E Tucker; Christopher R Jones
Journal:  Perm J       Date:  2020

4.  Biomechanical Analysis of Patellar Tendon Repair With Knotless Suture Anchor Tape Versus Transosseous Suture.

Authors:  Patrick A Massey; Mitchell Myers; Kaylan McClary; Jimmy Brown; R Shane Barton; Giovanni F Solitro
Journal:  Orthop J Sports Med       Date:  2020-10-02

5.  Prospective multicentre study of the clinical and functional outcomes following quadriceps tendon repair with suture anchors.

Authors:  F Mille; A Adam; S Aubry; G Leclerc; X Ghislandi; P Sergent; P Garbuio
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-10-06

Review 6.  Patellar tendon: From tendinopathy to rupture.

Authors:  Federica Rosso; Davide Edoardo Bonasia; Umberto Cottino; Federico Dettoni; Matteo Bruzzone; Roberto Rossi
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2015-08-07

7.  Surgical Technique: Repair of Patella Tendon Rupture in a Previously Harvested Tendon for an Anterior Cruciate Ligament Reconstruction.

Authors:  Micah Lissy; Urvi J Patel
Journal:  J Orthop Case Rep       Date:  2019

8.  Patellofemoral Joint Auto-fusion after Patella Tendon Repair: A Case Report.

Authors:  Thomas Herron; Travis Seaman; John Feighan
Journal:  J Orthop Case Rep       Date:  2021-08

9.  An improvement on the technique of transosseous tunnels for the fixation of lower pole patella fracture: Cerclage around the patella.

Authors:  Jialang Hu; Xin Guo
Journal:  Medicine (Baltimore)       Date:  2022-03-04       Impact factor: 1.817

10.  Patellar tendon re-rupture on the opposite end of the previous site of surgical repair.

Authors:  Bryan Thean Howe Koh; Andrew A Sayampanathan; Keng Thiam Lee
Journal:  Indian J Orthop       Date:  2017 May-Jun       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.