Prospective multicentre study of the clinical and functional outcomes following quadriceps tendon repair with suture anchors.

F Mille1,2, A Adam3,4, S Aubry3,4, G Leclerc3,4, X Ghislandi3,4, P Sergent3,4, P Garbuio3,4.   

Abstract

INTRODUCTION: Quadriceps tendon avulsions are typically treated by reattaching the tendon through bone tunnels, with or without tendon or hardware augmentation. The operated knee joint can be moved right away; however, tendon grafting or tension banding will be required to protect the repair, and the hardware must be removed later on. The goal of this study was to evaluate the clinical and functional outcomes when suture anchors are used to reattached torn quadriceps tendon, and also to assess tendon healing using MRI.
MATERIALS AND METHODS: Thirteen consecutive patients with avulsed quadriceps tendons were operated and then followed prospectively. The surgical technique consisted of tendon reattachment using at least three anchors, in addition to intratendinous weaving of the sutures. Weight bearing was allowed while using a splint. Rehabilitation was initiated immediately after surgery according to a set protocol.
RESULTS: Eleven patients were followed for a mean of 14.7 months. Two retears occurred in patients who did not wear the splint. Eighty-two per cent of patients were satisfied or very satisfied with the outcome. The mean knee flexion was 124.5°. All patients were able to return to their pre-injury activity levels. The mean time for clinical and functional recovery was 3 months. MRI performed 6 months after the surgical repair revealed good tendon healing. DISCUSSION: This was the first prospective study performed on quadriceps avulsion patients undergoing suture anchor repair. Prior clinical case reports have shown that this method leads to predictable clinical and functional results. Our results were comparable to those in published cases.
CONCLUSION: The procedure is simpler when only suture anchors are used. Tendon healing was observed on MRI in all cases. This simple, reproducible technique is free of the drawbacks associated with the typical repair augmentation.

Entities:  

Keywords:  Anchor; Early physical therapy; MRI; Quadriceps tendon

Mesh:

Year:  2015        PMID: 26441330     DOI: 10.1007/s00590-015-1710-6

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  37 in total

1.  Anchor design and bone mineral density affect the pull-out strength of suture anchors in rotator cuff repair: which anchors are best to use in patients with low bone quality?

Authors:  Markus J Tingart; Maria Apreleva; Janne Lehtinen; David Zurakowski; Jon J P Warner
Journal:  Am J Sports Med       Date:  2004-07-20       Impact factor: 6.202

2.  Internal fixation strength of suture anchors--update 1997.

Authors:  F A Barber; M A Herbert; J N Click
Journal:  Arthroscopy       Date:  1997-06       Impact factor: 4.772

3.  A rationale for assessing sports activity levels and limitations in knee disorders.

Authors:  F R Noyes; S D Barber; L A Mooar
Journal:  Clin Orthop Relat Res       Date:  1989-09       Impact factor: 4.176

4.  Rating systems in the evaluation of knee ligament injuries.

Authors:  Y Tegner; J Lysholm
Journal:  Clin Orthop Relat Res       Date:  1985-09       Impact factor: 4.176

5.  Suture anchor reinsertion of distal biceps rupture: clinical results and radiological assessment of tendon healing.

Authors:  D Gallinet; E Dietsch; B Barbier-Brion; J-M Lerais; L Obert
Journal:  Orthop Traumatol Surg Res       Date:  2011-03-29       Impact factor: 2.256

6.  A new method of repair for quadriceps tendon ruptures. A case report.

Authors:  P Maniscalco; C Bertone; F Rivera; L Bocchi
Journal:  Panminerva Med       Date:  2000-09       Impact factor: 5.197

7.  Outcomes following repair of quadriceps tendon ruptures.

Authors:  G A Konrath; D Chen; T Lock; H T Goitz; J T Watson; B R Moed; G D'Ambrosio
Journal:  J Orthop Trauma       Date:  1998-05       Impact factor: 2.512

8.  The epidemiology of musculoskeletal tendinous and ligamentous injuries.

Authors:  Robert A E Clayton; Charles M Court-Brown
Journal:  Injury       Date:  2008-11-25       Impact factor: 2.586

9.  A method of repair for quadriceps tendon or patellar ligament (tendon) ruptures without cast immobilization. Preliminary report.

Authors:  M Levy; J Goldstein; M Rosner
Journal:  Clin Orthop Relat Res       Date:  1987-05       Impact factor: 4.176

10.  The use of suture anchors to repair the ruptured quadriceps tendon.

Authors:  Brandon D Bushnell; George B Whitener; James H Rubright; R Alexander Creighton; Kevin J Logel; Mark L Wood
Journal:  J Orthop Trauma       Date:  2007-07       Impact factor: 2.512

View more
  6 in total

Review 1.  Extensor mechanism ruptures.

Authors:  Reha N Tandogan; Esref Terzi; Enrique Gomez-Barrena; Bruno Violante; Asim Kayaalp
Journal:  EFORT Open Rev       Date:  2022-05-31

2.  Outcomes After Repair of Quadriceps Tendon Rupture in Patients Aged 40 Years and Younger.

Authors:  Somnath Rao; Emma E Johnson; Taylor D'Amore; Stanley Szeto; Peters Otlans; Steven B Cohen
Journal:  Orthop J Sports Med       Date:  2022-05-18

Review 3.  Biomechanical Testing of Suture Anchor Versus Transosseous Tunnel Technique for Quadriceps Tendon Repair Yields Similar Outcomes: A Systematic Review.

Authors:  John W Belk; Adam Lindsay; Darby A Houck; Jason L Dragoo; James W Genuario; Stephanie W Mayer; Rachel M Frank; Eric C McCarty
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-09-30

4.  A Survey of Treatment Trends for Acute Quadriceps Tendon Ruptures Among North American Surgeons.

Authors:  Norah-Faye Matthies; Ryan A Paul; Tim Dwyer; Jaskarndip Chahal; Daniel Whelan
Journal:  Orthop J Sports Med       Date:  2022-03-30

5.  Clinical outcomes after treatment of quadriceps tendon ruptures show equal results independent of suture anchor or transosseus repair technique used - A pilot study.

Authors:  Stefan Plesser; Mohammad Keilani; Gyoergy Vekszler; Timothy Hasenoehrl; Stefano Palma; Martin Reschl; Richard Crevenna; Stefan Hajdu; Harald Kurt Widhalm
Journal:  PLoS One       Date:  2018-03-19       Impact factor: 3.240

6.  Safety and Performance of Titanium Suture Anchors Used in Knee Ligament Repair Procedures.

Authors:  Antonio Maestro; Iván Pipa; Nicolás Rodríguez; Carmen Toyos; Marcelino Torrontegui-Duarte; Cesar Castaño
Journal:  Medicina (Kaunas)       Date:  2021-03-19       Impact factor: 2.430

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.