Evaluating the efficacy of intra-aortic balloon pump timing using the auto-timing mode of operation with the Datascope CS100.

Melissa K Osentowski1, David W Holt.   

Abstract

The intra-aortic balloon pump (IABP) was first introduced by Moulopoulos et al. in 1962 and was described clinically by Kantrowitz et al. in 1968. The subsequent development of the IABP has resulted in its widespread application, resulting in >70,000 applications per year, making it the most common cardiac assist device after pharmacologic intervention. The correct timing of the inflation and deflation of this device is critical to it being clinically advantageous to the patient. The purpose of this study was primarily to examine the Datascope CS100 automated timing of inflation and deflation, and secondarily, to create an awareness of the risks of solely relying on technology for patient treatment decisions in lieu of clinical evaluative skills. Timing data were collected from 165 IABP patients from January 1, 2003 to March 31, 2005 using the Datascope series System 97, System 98, and CS100 IABP consoles. Timing criteria used in the evaluation of the IABP in this study included proper inflation, defined as inflation at the dicrotic notch of arterial pressure waveform, and proper deflation, resulting in a presystolic decrease of diastolic pressure by 5-10 mmHg. These parameters were evaluated by examining a printed strip from the IABP console after timing selection stabilization. Before implementation of the CS100, 78.6% of inflations and 53.6% of deflations were correct when using the criteria listed above. After implementation of the CS100, 83.3% of inflations were correct and 44.4% of deflations were correct. Although improvement in consistency of IABP inflation quality was observed, a net decrease in the quality of IABP deflations was also observed. Total reliance on the autotiming operation mode of the CS100 may not be warranted, and imposing clinical judgment in therapeutic application is necessary to avoid dangerous timing errors. An awareness of the dangers of solely relying on technology for patient treatment decisions vs. the use of technology combined with clinical evaluative skills for assessing therapeutic intervention to improve patient care is discussed.

Entities:  

Mesh:

Year:  2007        PMID: 17672189      PMCID: PMC4680672     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  5 in total

1.  Portable infusion pumps used for continuous regional analgesia: delivery rate accuracy and consistency.

Authors:  Brian M Ilfeld; Timothy E Morey; F Kayser Enneking
Journal:  Reg Anesth Pain Med       Date:  2003 Sep-Oct       Impact factor: 6.288

2.  Evaluation of electronic, digital blood glucose monitors.

Authors:  N S Latman
Journal:  Biomed Instrum Technol       Date:  1991 Jan-Feb

3.  The accuracy and reliability of commercial heart rate monitors.

Authors:  M J Burke; M V Whelan
Journal:  Br J Sports Med       Date:  1987-03       Impact factor: 13.800

4.  Accuracy and reliability of disposable pressure transducers coupled with modern pressure monitors.

Authors:  R M Gardner
Journal:  Crit Care Med       Date:  1996-05       Impact factor: 7.598

5.  Clinical thermometry: possible causes and potential solutions to electronic, digital thermometer inaccuracies.

Authors:  Neal S Latman
Journal:  Biomed Instrum Technol       Date:  2003 May-Jun
  5 in total
  1 in total

1.  Biventricular pacing in conjunction with epicardial atrial pacing adversely affects timing of intra-aortic balloon pump.

Authors:  David A Cross; William E Johnston
Journal:  J Extra Corpor Technol       Date:  2010-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.