Literature DB >> 3580725

The accuracy and reliability of commercial heart rate monitors.

M J Burke, M V Whelan.   

Abstract

In recent years increasing emphasis has been placed on the benefits of exercise to normal healthy adults as well as to those recovering from heart attacks and other illnesses. As an aid to exercise training many portable heart-rate monitors have been placed on the market but little appears to have been done to assess the performance of these machines. The authors have examined the performance of four such monitors both under bench-test and practical exercising conditions. When tested on the bench using electronic equipment, the machines rarely exhibited errors exceeding 2-3 bpm over a measurement range of 30-240 bpm. However, when tested with subjects walking or jogging at low speeds on a treadmill, typically 20-70% of the readings given by the machines had errors of greater than 20 bpm. In some cases over 50% of readings had errors exceeding 50 bpm.

Entities:  

Mesh:

Year:  1987        PMID: 3580725      PMCID: PMC1478597          DOI: 10.1136/bjsm.21.1.29

Source DB:  PubMed          Journal:  Br J Sports Med        ISSN: 0306-3674            Impact factor:   13.800


  7 in total

1.  Validity of the postexercise heart rate as a means of estimating heart rate during work of varying intensities.

Authors:  W D McArdle; L Zwiren; J R Magel
Journal:  Res Q       Date:  1969-10

2.  The cardiovascular response to chronic physical exertion and exercise training: an echocardiographic review.

Authors:  W F Graettinger
Journal:  Am Heart J       Date:  1984-10       Impact factor: 4.749

3.  Exercise as protection against heart attack.

Authors:  R S Paffenbarger; R T Hyde
Journal:  N Engl J Med       Date:  1980-05-01       Impact factor: 91.245

4.  Noninvasive evaluation of exercise training in college-age men.

Authors:  T D Adams; F G Yanowitz; A G Fisher; J D Ridges; K Lovell; T A Pryor
Journal:  Circulation       Date:  1981-11       Impact factor: 29.690

5.  Reasons for dropout from exercise programs in post-coronary patients.

Authors:  G M Andrew; N B Oldridge; J O Parker; D A Cunningham; P A Rechnitzer; N L Jones; C Buck; T Kavanagh; R J Shephard; J R Sutton
Journal:  Med Sci Sports Exerc       Date:  1981       Impact factor: 5.411

6.  Physical fitness and incidence of hypertension in healthy normotensive men and women.

Authors:  S N Blair; N N Goodyear; L W Gibbons; K H Cooper
Journal:  JAMA       Date:  1984-07-27       Impact factor: 56.272

7.  A natural history of athleticism and cardiovascular health.

Authors:  R S Paffenbarger; R T Hyde; A L Wing; C H Steinmetz
Journal:  JAMA       Date:  1984-07-27       Impact factor: 56.272

  7 in total
  4 in total

1.  Evaluating the efficacy of intra-aortic balloon pump timing using the auto-timing mode of operation with the Datascope CS100.

Authors:  Melissa K Osentowski; David W Holt
Journal:  J Extra Corpor Technol       Date:  2007-06

2.  Low-power ECG amplifier/detector for dry-electrode heart rate monitoring.

Authors:  M J Burke
Journal:  Med Biol Eng Comput       Date:  1994-11       Impact factor: 2.602

Review 3.  Quantification of training in competitive sports. Methods and applications.

Authors:  W G Hopkins
Journal:  Sports Med       Date:  1991-09       Impact factor: 11.136

4.  Impact of training specificity on exercise-induced cardiac troponin elevation in professional athletes: A pilot study.

Authors:  Johan O Wedin; Nicolena S Nyberg; Anders E Henriksson
Journal:  World J Cardiol       Date:  2020-01-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.