Literature DB >> 17668940

Technical description, phantom accuracy, and clinical feasibility for single-session lung radiosurgery using robotic image-guided real-time respiratory tumor tracking.

A Muacevic1, C Drexler, B Wowra, A Schweikard, A Schlaefer, R T Hoffmann, R Wilkowski, H Winter, M Reiser.   

Abstract

To describe the technological background, the accuracy, and clinical feasibility for single session lung radiosurgery using a real-time robotic system with respiratory tracking. The latest version of image-guided real-time respiratory tracking software (Synchrony, Accuray Incorporated, Sunnyvale, CA) was applied and is described. Accuracy measurements were performed using a newly designed moving phantom model. We treated 15 patients with 19 lung tumors with robotic radiosurgery (CyberKnife, Accuray) using the same treatment parameters for all patients. Ten patients had primary tumors and five had metastatic tumors. All patients underwent computed tomography-guided percutaneous placement of one fiducial directly into the tumor, and were all treated with single session radiosurgery to a dose of 24 Gy. Follow up CT scanning was performed every two months. All patients could be treated with the automated robotic technique. The respiratory tracking error was less than 1 mm and the overall shape of the dose profile was not affected by target motion and/or phase shift between fiducial and optical marker motion. Two patients required a chest tube insertion after fiducial implantation because of pneumothorax. One patient experienced nausea after treatment. No other short-term adverse reactions were found. One patient showed imaging signs of pneumonitis without a clinical correlation. Single-session radiosurgery for lung tumor tracking using the described technology is a stable, safe, and feasible concept for respiratory tracking of tumors during robotic lung radiosurgery in selected patients. Longer follow-up is needed for definitive clinical results.

Entities:  

Mesh:

Year:  2007        PMID: 17668940     DOI: 10.1177/153303460700600409

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  10 in total

1.  Correlation and prediction uncertainties in the cyberknife synchrony respiratory tracking system.

Authors:  Eric W Pepin; Huanmei Wu; Yuenian Zhang; Bryce Lord
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

2.  [Chronic uveitis with secondary glaucoma?].

Authors:  I Huebert; A Muacevic; A Kampik; K H Eibl-Lindner
Journal:  Ophthalmologe       Date:  2013-07       Impact factor: 1.059

3.  Robotic stereotactic body radiation therapy for elderly medically inoperable early-stage non-small cell lung cancer.

Authors:  Sana D Karam; Zachary D Horne; Robert L Hong; Nimrah Baig; Gregory J Gagnon; Don McRae; David Duhamel; Nadim M Nasr
Journal:  Lung Cancer (Auckl)       Date:  2013-08-06

4.  Quality of radiosurgery for single brain metastases with respect to treatment technology: a matched-pair analysis.

Authors:  Berndt Wowra; Alexander Muacevic; Jörg-Christian Tonn
Journal:  J Neurooncol       Date:  2009-02-01       Impact factor: 4.130

5.  Institutional experience on the treatment of lung and liver lesions with stereotactic body radiotherapy and Novalis Exactrac Adaptive Gating technique.

Authors:  Ovidio Hernando-Requejo; Emilio Sánchez; Pedro Fernández; Daniel Zucca; Juan M Pérez; Mariola García-Aranda; Jeannette Valero; Mercedes López; Raquel Ciérvide; Carmen Rubio
Journal:  J Radiosurg SBRT       Date:  2011

6.  A constrained linear regression optimization algorithm for diaphragm motion tracking with cone beam CT projections.

Authors:  Jie Wei; Ming Chao
Journal:  Phys Med       Date:  2018-01-11       Impact factor: 2.685

7.  Accelerated Partial Breast Irradiation: Using the CyberKnife as the Radiation Delivery Platform in the Treatment of Early Breast Cancer.

Authors:  Sandra Vermeulen; Cristian Cotrutz; Astrid Morris; Robert Meier; Claire Buchanan; Patricia Dawson; Bruce Porter
Journal:  Front Oncol       Date:  2011-11-21       Impact factor: 6.244

8.  Stability and Reliability of Enhanced External-Internal Motion Correlation via Dynamic Phase-Shift Corrections Over 30-min Timeframe for Respiratory-Gated Radiotherapy.

Authors:  Andrew Milewski; Guang Li
Journal:  Technol Cancer Res Treat       Date:  2022 Jan-Dec

9.  CyberKnife Radiosurgery - Value as an Adjunct to Surgical Treatment of HCC?

Authors:  Markus Schoenberg; Andrey Khandoga; Sebastian Stintzing; Christoph Trumm; Tobias Simon Schiergens; Martin Angele; Mark Op den Winkel; Jens Werner; Alexander Muacevic; Markus Rentsch
Journal:  Cureus       Date:  2016-04-28

10.  Image-Guided Robotic Radiosurgery for the Treatment of Lung Metastases of Renal Cell Carcinoma-A Retrospective, Single Center Analysis.

Authors:  Severin Rodler; Melanie Götz; Jan-Niclas Mumm; Alexander Buchner; Annabel Graser; Jozefina Casuscelli; Christian Stief; Christoph Fürweger; Alexander Muacevic; Michael Staehler
Journal:  Cancers (Basel)       Date:  2022-01-12       Impact factor: 6.639

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.