Literature DB >> 17664609

2D linear and iterative reconstruction algorithms for a PET-insert scanner.

Debashish Pal1, Joseph A O'sullivan, Heyu Wu, Martin Janecek, Yuan-Chuan Tai.   

Abstract

We are developing novel insert devices for existing whole body PET scanners to achieve better resolution in selected regions of interest such as the head, neck, breast or abdomen. The insert considered here is a full ring of high resolution detectors, which can be placed around the object of interest. Adding the insert inside the scanner leads to three different types of coincidences: insert-insert, insert-scanner and scanner-scanner. The insert-insert and scanner-scanner coincidences are similar to the coincidences obtained in a traditional PET system. The insert-scanner coincidences have an inherent fan-beam geometry for which a spatially variant system matrix is proposed. The system matrix is computed using the intersection of a fan beam with a pixel. A filtered back-projection (FBP) algorithm for the insert-scanner geometry is presented. This FBP algorithm yields images with significantly reduced artifacts compared to FBP reconstructions on insert-scanner data rebinned into parallel beams. This is demonstrated using simulated point source data acquired using SimSET. It is proposed to use a penalized ML-EM (PML-EM) algorithm using a log-cosh roughness penalty function to reconstruct a single activity distribution from all three data sets. This is demonstrated qualitatively using simulated point source data. A quantitative comparison of PML-EM and FBP was performed on data acquired from insert-scanner coincidences using a phantom with hot and cold tumors imaged in an experimental setup. The quantitative studies demonstrate that the resolution/noise tradeoff of PML-EM is improved relative to FBP.

Entities:  

Mesh:

Year:  2007        PMID: 17664609     DOI: 10.1088/0031-9155/52/14/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  A generalized reconstruction framework for unconventional PET systems.

Authors:  Aswin John Mathews; Ke Li; Sergey Komarov; Qiang Wang; Bosky Ravindranath; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Improving PET imaging for breast cancer using virtual pinhole PET half-ring insert.

Authors:  Aswin John Mathews; Sergey Komarov; Heyu Wu; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Phys Med Biol       Date:  2013-09-02       Impact factor: 3.609

3.  Virtual-pinhole PET.

Authors:  Yuan-Chuan Tai; Heyu Wu; Debashish Pal; Joseph A O'Sullivan
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

4.  A DOI Detector With Crystal Scatter Identification Capability for High Sensitivity and High Spatial Resolution PET Imaging.

Authors:  Z Gu; D L Prout; R W Silverman; H Herman; A Dooraghi; A F Chatziioannou
Journal:  IEEE Trans Nucl Sci       Date:  2015-06       Impact factor: 1.679

5.  Image reconstruction and system modeling techniques for virtual-pinhole PET insert systems.

Authors:  Daniel B Keesing; Aswin Mathews; Sergey Komarov; Heyu Wu; Tae Yong Song; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Phys Med Biol       Date:  2012-04-11       Impact factor: 3.609

6.  Investigation of the limitations of the highly pixilated CdZnTe detector for PET applications.

Authors:  Sergey Komarov; Yongzhi Yin; Heyu Wu; Jie Wen; Henric Krawczynski; Ling-Jian Meng; Yuan-Chuan Tai
Journal:  Phys Med Biol       Date:  2012-10-18       Impact factor: 3.609

7.  Micro insert: a prototype full-ring PET device for improving the image resolution of a small-animal PET scanner.

Authors:  Heyu Wu; Debashish Pal; Tae Yong Song; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  J Nucl Med       Date:  2008-09-15       Impact factor: 10.057

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.