Literature DB >> 17664545

A novel patch-field design using an optimized grid filter for passively scattered proton beams.

Yupeng Li1, Xiaodong Zhang, Lei Dong, Radhe Mohan.   

Abstract

For tumors with highly complex shapes, a 'patching' strategy is often used in passively scattered proton therapy to match the sharp distal edge of the spread-out Bragg peak (SOBP) of the patch field to the lateral penumbra of the through field at 50% dose level. The differences in the dose gradients at the distal edge and at the lateral penumbra could cause hot and cold doses at the junction. In this note, we describe an algorithm developed to optimize the range compensator design to yield a more uniform dose distribution at the junction. The algorithm is based on the fact that the distal fall-off of the SOBP can be tailored using a grid filter that is placed perpendicular to the beam's path. The filter is optimized so that the distal fall-off of the patch field complements the lateral penumbra fall-off of the through field. In addition to optimizing the fall-off, the optimization process implicitly accounts for the limitations of conventional compensator design algorithms. This algorithm uses simple ray tracing to determine the compensator shape and ignore scatter. The compensated dose distribution may therefore differ substantially from the intended dose distribution, especially when complex heterogeneities are encountered, such as those in the head and neck. In such a case, an adaptive optimization strategy can be used to optimize the 'grid' filter locally considering the tissue heterogeneities. The grid filter thus obtained is superimposed on the original range compensator so that the composite compensator leads to a more uniform dose distribution at the patch junction. An L-shaped head and neck tumor was used to demonstrate the validity of the proposed algorithm. A robustness analysis with focus on range uncertainty effect is carried out.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17664545     DOI: 10.1088/0031-9155/52/12/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Adjustment of the lateral and longitudinal size of scanned proton beam spots using a pre-absorber to optimize penumbrae and delivery efficiency.

Authors:  Uwe Titt; Dragan Mirkovic; Gabriel O Sawakuchi; Luis A Perles; Wayne D Newhauser; Phillip J Taddei; Radhe Mohan
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

2.  Uncertainty incorporated beam angle optimization for IMPT treatment planning.

Authors:  Wenhua Cao; Gino J Lim; Andrew Lee; Yupeng Li; Wei Liu; X Ronald Zhu; Xiaodong Zhang
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

3.  Designed-seamless irradiation technique for extended whole mediastinal proton-beam irradiation for esophageal cancer.

Authors:  Noriyuki Okonogi; Takatuki Hashimoto; Masaya Ishida; Toshiki Ohno; Toshiyuki Terunuma; Toshiyuki Okumura; Takeji Sakae; Hideyuki Sakurai
Journal:  Radiat Oncol       Date:  2012-10-19       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.