Literature DB >> 17659614

2D arbitrary shape-selective excitation summed spectroscopy (ASSESS).

Qin Qin1,2,3, John C Gore4,3, Mark D Does4,3, Malcolm J Avison3, Robin A de Graaf1,2.   

Abstract

Conventional single-voxel localization for MR spectroscopy (MRS) is restricted to selecting only rectangular-shaped regions of interest (ROIs). The complexity of tissue shapes of interest and the desire to maximize the signal-to-noise ratio (SNR) while minimizing partial-volume effects require more sophisticated localization techniques. A group of spatially selective RF pulses are proposed in this work for the measurement of spectra from regions of arbitrary shape based on using a radial trajectory in k-space. Utilizing a single k-line per excitation results in a broad spectroscopic bandwidth. However, spatial localization accuracy is compromised for nutation angles > 10 degrees because of the small-tip-angle approximation of the Bloch equations. By interleaving multiple radial k-lines per excitation with nonselective refocusing pulses, one can achieve accurate localization for nutation angles up to 90 degrees while simultaneously maintaining the spectral bandwidth. The technique is described and compared with existing localization methods, and in vivo results are demonstrated. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17659614     DOI: 10.1002/mrm.21274

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   3.737


  8 in total

1.  Reduced field-of-view excitation using second-order gradients and spatial-spectral radiofrequency pulses.

Authors:  Chao Ma; Dan Xu; Kevin F King; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2012-04-05       Impact factor: 4.668

2.  Quantitative T2 measurement of a single voxel with arbitrary shape using pinwheel excitation and CPMG acquisition.

Authors:  Qin Qin; John C Gore; Robin A de Graaf; Mark D Does
Journal:  MAGMA       Date:  2007-11-13       Impact factor: 2.310

3.  Correcting partial volume effects in biexponential T2 estimation of small lesions.

Authors:  Chuan Huang; Jean-Philippe Galons; Christian G Graff; Eric W Clarkson; Ali Bilgin; Bobby Kalb; Diego R Martin; Maria I Altbach
Journal:  Magn Reson Med       Date:  2014-04-17       Impact factor: 4.668

4.  Evaluation of 2D spatially selective MR spectroscopy using parallel excitation at 7 T.

Authors:  Gopesh Patel; Martin Haas; Niravkumar Darji; Oliver Speck
Journal:  Quant Imaging Med Surg       Date:  2015-06

5.  Accelerated imaging with segmented 2D pulses using parallel imaging and virtual coils.

Authors:  Michael Mullen; Alexander Gutierrez; Naoharu Kobayashi; Jarvis Haupt; Michael Garwood
Journal:  J Magn Reson       Date:  2019-07-04       Impact factor: 2.229

6.  Slice with angulated non-parallel boundaries.

Authors:  Busik Park; Martin J Lizak; Yun Xiang; Jun Shen
Journal:  J Magn Reson       Date:  2011-02-18       Impact factor: 2.229

7.  Signal scaling improves the signal-to-noise ratio of measurements with segmented 2D-selective radiofrequency excitations.

Authors:  Jürgen Finsterbusch; Martin G Busch; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2013-02-25       Impact factor: 4.668

8.  Design of multidimensional Shinnar-Le Roux radiofrequency pulses.

Authors:  Chao Ma; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2014-02-27       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.