Literature DB >> 17652739

Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography.

Sunita Radhakrishnan1, Jovina See, Scott D Smith, Winifred P Nolan, Zheng Ce, David S Friedman, David Huang, Yan Li, Tin Aung, Paul T K Chew.   

Abstract

PURPOSE: To evaluate the reproducibility of anterior chamber (AC) angle measurements obtained using anterior segment optical coherence tomography (AS-OCT).
METHODS: Patients with suspected glaucoma and those with glaucoma, ocular hypertension, or anatomically narrow angles were recruited from the glaucoma service at the National University Hospital, Singapore. All subjects underwent imaging of the nasal, temporal, and inferior AC angles with an AS-OCT prototype under standardized dark and light conditions. For short-term reproducibility analysis, a single observer acquired two sets of images followed by a third set of images acquired by a second observer. The interval between sessions was 10 minutes. For long-term reproducibility analysis, a single observer acquired two sets of images at least 24 hours apart. Images were measured using custom software to determine the AC depth (ACD), angle opening distance at 500 microm (AOD(500)), angle recess area at 500 microm (ARA(500)), and trabecular-iris space area at 500 microm (TISA(500)). The intraclass correlation coefficient (ICC) was calculated as a measure of intraobserver and interobserver reproducibility.
RESULTS: Twenty eyes of 20 patients were analyzed for short-term reproducibility, and 23 eyes of 23 patients were analyzed for long-term reproducibility. AC depth measurement demonstrated excellent reproducibility (ICC 0.93-1.00) in both dark and light conditions. For the nasal and temporal quadrants, all AC angle parameters demonstrated good to excellent short-term (ICC 0.67-0.90) and long-term (ICC 0.56-0.93) reproducibility in both dark and light conditions. In the inferior quadrant, reproducibility was lower in all categories of analysis and varied from poor to good (ICC 0.31-0.73).
CONCLUSIONS: AS-OCT allows quantitative assessment of the AC angle. The reproducibility of AC angle measurements was good to excellent for the nasal and temporal quadrants. The lower reproducibility of measurements in the inferior quadrant may be unique to this prototype due to difficulty in acquiring high-quality images of the inferior angle. Further assessment of the commercially available AS-OCT is needed to clarify this finding.

Entities:  

Mesh:

Year:  2007        PMID: 17652739     DOI: 10.1167/iovs.06-1120

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  34 in total

1.  Changes in anterior segment morphology in response to illumination and after laser iridotomy in Asian eyes: an anterior segment OCT study.

Authors:  Jovina L S See; Paul T K Chew; Scott D Smith; Winifred P Nolan; Yiong-Huak Chan; David Huang; Ce Zheng; Paul J Foster; Tin Aung; David S Friedman
Journal:  Br J Ophthalmol       Date:  2007-05-15       Impact factor: 4.638

2.  Anterior chamber angle imaging with optical coherence tomography.

Authors:  C K-S Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-14       Impact factor: 3.775

Review 3.  High-Resolution Optical Coherence Tomography as an Adjunctive Tool in the Diagnosis of Corneal and Conjunctival Pathology.

Authors:  Afshan A Nanji; Fouad E Sayyad; Anat Galor; Sander Dubovy; Carol L Karp
Journal:  Ocul Surf       Date:  2015-04-06       Impact factor: 5.033

4.  Optimal number of angle images for calculating anterior angle volume and iris volume measurements.

Authors:  Lauren S Blieden; Alice Z Chuang; Laura A Baker; Nicholas P Bell; Timothy S Fuller; Kimberly A Mankiewicz; Robert M Feldman
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-05       Impact factor: 4.799

5.  Wide-field whole eye OCT system with demonstration of quantitative retinal curvature estimation.

Authors:  Ryan P McNabb; James Polans; Brenton Keller; Moseph Jackson-Atogi; Charlene L James; Robin R Vann; Joseph A Izatt; Anthony N Kuo
Journal:  Biomed Opt Express       Date:  2018-12-21       Impact factor: 3.732

Review 6.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

7.  Association between baseline angle width and induced angle opening following prophylactic laser peripheral iridotomy.

Authors:  Roland Y Lee; Toshimitsu Kasuga; Qi N Cui; Guofu Huang; Mingguang He; Shan C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-05-01       Impact factor: 4.799

8.  Light-dark changes in iris thickness and anterior chamber angle width in eyes with occludable angles.

Authors:  Fumitaka Hirose; Masayuki Hata; Shin-ichiro Ito; Takaaki Matsuki; Yasuo Kurimoto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-05-21       Impact factor: 3.117

9.  Comparison of anterior segment morphology following prophylactic laser peripheral iridotomy in Caucasian and Chinese eyes.

Authors:  Roland Y Lee; Toshimitsu Kasuga; Qi N Cui; Guofu Huang; Mingguang He; Shan C Lin
Journal:  Clin Exp Ophthalmol       Date:  2013-10-29       Impact factor: 4.207

10.  Full anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm.

Authors:  Peng Li; Murray Johnstone; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2014-04       Impact factor: 3.170