Nocturnal hypoglycaemias in type 1 diabetic patients: what can we learn with continuous glucose monitoring?

L Guillod1, S Comte-Perret, D Monbaron, R C Gaillard, J Ruiz.   

Abstract

AIM: In type 1 diabetic patients (T1DM), nocturnal hypoglycaemias (NH) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in T1DM, the best SMBG time to predict NH, the relationship between morning hyperglycaemia and NH (Somogyi phenomenon) and the utility of CGMS to reduce NH.
METHODS: Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluation, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months.
RESULTS: The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR=2.37, P=0.001), while a single measure < or =4 mmol/l at 3-hour had a sensitivity of 43% (OR=4.60, P<0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR=3.95, P<0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P<0.001).
CONCLUSION: NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17652003     DOI: 10.1016/j.diabet.2007.03.007

Source DB:  PubMed          Journal:  Diabetes Metab        ISSN: 1262-3636            Impact factor:   6.041


  12 in total

1.  Effect of short-term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus.

Authors:  Raymond J Davey; Timothy W Jones; Paul A Fournier
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

2.  Susceptibility of interstitial continuous glucose monitor performance to sleeping position.

Authors:  Brett D Mensh; Natalie A Wisniewski; Brian M Neil; Daniel R Burnett
Journal:  J Diabetes Sci Technol       Date:  2013-07-01

Review 3.  Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.

Authors:  Kazuhiro Hanazaki; Masaya Munekage; Hiroyuki Kitagawa; Tomoaki Yatabe; Eri Munekage; Mai Shiga; Hiromichi Maeda; Tsutomu Namikawa
Journal:  J Artif Organs       Date:  2016-05-03       Impact factor: 1.731

Review 4.  Continuous Glucose Monitoring: Impact on Hypoglycemia.

Authors:  Cornelis A J van Beers; J Hans DeVries
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

5.  Insight into hypoglycemia in pediatric type 1 diabetes mellitus.

Authors:  Kimberly E Lehecka; Venkat S Renukuntla; Rubina A Heptulla
Journal:  Int J Pediatr Endocrinol       Date:  2012-06-20

6.  Continuous glucose monitoring reveals hypoglycemia risk in elderly patients with type 2 diabetes mellitus.

Authors:  Takahiro Ishikawa; Masaya Koshizaka; Yoshiro Maezawa; Minoru Takemoto; Yoshiharu Tokuyama; Toshihiro Saito; Koutaro Yokote
Journal:  J Diabetes Investig       Date:  2017-05-24       Impact factor: 4.232

Review 7.  Hypoglycemia in Patients with Diabetes and Renal Disease.

Authors:  Mazen Alsahli; John E Gerich
Journal:  J Clin Med       Date:  2015-05-13       Impact factor: 4.241

Review 8.  Continuous Glucose Monitoring Systems: A Review.

Authors:  Sandeep Kumar Vashist
Journal:  Diagnostics (Basel)       Date:  2013-10-29

9.  Glucose sensing in the peritoneal space offers faster kinetics than sensing in the subcutaneous space.

Authors:  Daniel R Burnett; Lauren M Huyett; Howard C Zisser; Francis J Doyle; Brett D Mensh
Journal:  Diabetes       Date:  2014-03-12       Impact factor: 9.461

10.  Prediction of Nocturnal Hypoglycemia in Adults with Type 1 Diabetes under Multiple Daily Injections Using Continuous Glucose Monitoring and Physical Activity Monitor.

Authors:  Arthur Bertachi; Clara Viñals; Lyvia Biagi; Ivan Contreras; Josep Vehí; Ignacio Conget; Marga Giménez
Journal:  Sensors (Basel)       Date:  2020-03-19       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.