Cardiac output estimation after off-pump coronary artery bypass: a comparison of two different techniques.

Dheeraj Arora1, Rajesh Chand, Yatin Mehta, Naresh Trehan.   

Abstract

The present study compares the cardiac output (CO) estimated by a new, non-invsive continuous Doppler device (Ultrasonic cardiac output monitor-USCOM) with that by bolus thermodilution technique (TD). Thirty post off-pump coronary artery bypass graft surgery patients were studied in this prospective nonrandomized study. Right heart CO estimation by USCOM and TD was performed and measured in quadruplet. A total of 120 paired observations were made. The mean CO was 4.63 and 4.76 Llmin as estimated by TD and USCOM respectively. For TD and USCOM, the CO had a mean bias (tendency of one technique to differ from other) of -0.13 L/min and limits of agreement (mean bias +/- 2SD) at -0.86 and 0.59 L/min. The study reveals very good agreement between the values of CO estimated by USCOM and TD.

Entities:  

Mesh:

Year:  2007        PMID: 17644886     DOI: 10.4103/0971-9784.37939

Source DB:  PubMed          Journal:  Ann Card Anaesth        ISSN: 0971-9784


  7 in total

1.  In vitro evaluation of an ultrasonic cardiac output monitoring (USCOM) device.

Authors:  Shaun D Gregory; Helena Cooney; Sara Diab; Chris Anstey; Ogilvie Thom; John F Fraser
Journal:  J Clin Monit Comput       Date:  2015-03-07       Impact factor: 2.502

Review 2.  Minimally invasive monitoring of cardiac output in the cardiac surgery intensive care unit.

Authors:  Jamal A Alhashemi; Maurizio Cecconi; Giorgio della Rocca; Maxime Cannesson; Christoph K Hofer
Journal:  Curr Heart Fail Rep       Date:  2010-09

Review 3.  Newer methods of cardiac output monitoring.

Authors:  Yatin Mehta; Dheeraj Arora
Journal:  World J Cardiol       Date:  2014-09-26

4.  Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network.

Authors:  S M M Naidu; Prem C Pandey; Uttam R Bagal; Suhas P Hardas
Journal:  Med Biol Eng Comput       Date:  2017-11-18       Impact factor: 2.602

5.  Pulmonary Artery Catheter (PAC) Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM): An Ovine Cardiac Output Validation.

Authors:  Robert A Phillips; Sally G Hood; Beverley M Jacobson; Malcolm J West; Li Wan; Clive N May
Journal:  Crit Care Res Pract       Date:  2012-05-09

6.  Recent trends on hemodynamic monitoring in cardiac surgery.

Authors:  Dheeraj Arora; Yatin Mehta
Journal:  Ann Card Anaesth       Date:  2016 Oct-Dec

7.  Cardiac output measurements via echocardiography versus thermodilution: A systematic review and meta-analysis.

Authors:  Yun Zhang; Yan Wang; Jing Shi; Zhiqiang Hua; Jinyu Xu
Journal:  PLoS One       Date:  2019-10-03       Impact factor: 3.240