Literature DB >> 17637397

Reduced neutron production through use of a flattening-filter-free accelerator.

Stephen F Kry1, Uwe Titt, Falk Pönisch, Oleg N Vassiliev, Mohammad Salehpour, Michael Gillin, Radhe Mohan.   

Abstract

PURPOSE: To measure and compare neutron fluence around an accelerator operating at 18 MV, both with the flattening filter present (FF mode) and absent (flattening-filter-free [FFF] mode). METHODS AND MATERIALS: The neutron fluence was measured at several locations in the patient plane using gold foil activation in neutron moderators. Differences in neutron fluence between the FF and FFF mode were assessed in three frameworks: (1) measured per monitor unit of machine-on time, (2) determined per dose on the central axis, and (3) determined for a complete course of prostate intensity-modulated radiotherapy.
RESULTS: Neutron fluence per monitor unit was approximately 20% lower when the accelerator was operated in the FFF mode than when it was in FF mode. The total amount of neutron fluence that would be obtained during the entire course of prostate intensity-modulate radiotherapy was 69% lower when the accelerator was operated in the FFF mode than when it was in the FF mode. This reduction in neutron fluence would correspond to a drastic reduction in the neutron dose equivalent received by the patient as a byproduct of high-energy radiotherapy. It would also correspond to a reduction in activation within the treatment vault and subsequent exposure to radiation therapists.
CONCLUSION: When feasible, operating the accelerator without a FF will benefit both patients and radiation therapists by reducing the number of unwanted neutrons and resultant exposure. This reduces the risk of negative effects from such exposure (e.g., second cancers).

Entities:  

Mesh:

Year:  2007        PMID: 17637397     DOI: 10.1016/j.ijrobp.2007.04.002

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  23 in total

Review 1.  A review on photoneutrons characteristics in radiation therapy with high-energy photon beams.

Authors:  Alireza Naseri; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

2.  Measurement and comparison of head scatter factor for 7 MV unflattened (FFF) and 6 MV flattened photon beam using indigenously designed columnar mini phantom.

Authors:  Sigamani Ashokkumar; Arunai Nambiraj; Sujit Nath Sinha; Girigesh Yadav; Kothanda Raman; Manindra Bhushan; Rajesh Thiyagarajan
Journal:  Rep Pract Oncol Radiother       Date:  2015-03-01

3.  Impact of flattening-filter-free radiation on the clonogenic survival of astrocytic cell lines.

Authors:  Caroline Steenken; Jens Fleckenstein; Stefan Kegel; Lennart Jahnke; Anna Simeonova; Linda Hartmann; Jens Kübler; Marlon R Veldwijk; Frederik Wenz; Carsten Herskind; Frank Anton Giordano
Journal:  Strahlenther Onkol       Date:  2015-03-13       Impact factor: 3.621

4.  Improved clinical efficiency in CNS stereotactic radiosurgery using a flattening filter free linear accelerator.

Authors:  Brendan M Prendergast; Richard A Popple; Grant M Clark; Sharon A Spencer; Bart Guthrie; James Markert; John B Fiveash
Journal:  J Radiosurg SBRT       Date:  2011

5.  Safety and feasibility of prostate stereotactic ablative radiotherapy using multimodality imaging and flattening filter free.

Authors:  Aileen Duffton; Azmat Sadozye; Lynsey Devlin; Nicholas MacLeod; Carolynn Lamb; Suzanne Currie; Philip McLoone; Marimuthu Sankaralingam; John Foster; Stephanie Paterson; Stefanie Keatings; David Dodds
Journal:  Br J Radiol       Date:  2018-02-01       Impact factor: 3.039

6.  Fidelity of dose delivery at high dose rate of volumetric modulated arc therapy in a truebeam linac with flattening filter free beams.

Authors:  Georgios Kalantzis; Jianguo Qian; Bin Han; Gary Luxton
Journal:  J Med Phys       Date:  2012-10

7.  Unflattened photon beams from the standard flattening filter free accelerators for radiotherapy: Advantages, limitations and challenges.

Authors:  Sunil Dutt Sharma
Journal:  J Med Phys       Date:  2011-07

8.  Stereotactic body radiation therapy (SBRT) for lung malignancies: preliminary toxicity results using a flattening filter-free linear accelerator operating at 2400 monitor units per minute.

Authors:  Brendan M Prendergast; Michael C Dobelbower; James A Bonner; Richard A Popple; Craig J Baden; Douglas J Minnich; Robert J Cerfolio; Sharon A Spencer; John B Fiveash
Journal:  Radiat Oncol       Date:  2013-11-20       Impact factor: 3.481

9.  Comparison of Head Scatter Factor for 6MV and 10MV flattened (FB) and Unflattened (FFF) Photon Beam using indigenously Designed Columnar Mini Phantom.

Authors:  Sigamani Ashokkumar; N Arunai Nambi Raj; Sujit Nath Sinha; Girigesh Yadav; Rajesh Thiyagarajan; Kothanda Raman; Manindra Bhushan Mishra
Journal:  J Med Phys       Date:  2014-07

10.  Dosimetric differences in flattened and flattening filter-free beam treatment plans.

Authors:  Yue Yan; Poonam Yadav; Michael Bassetti; Kaifang Du; Daniel Saenz; Paul Harari; Bhudatt R Paliwal
Journal:  J Med Phys       Date:  2016 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.