Literature DB >> 17634645

Monte Carlo study of neutron dose equivalent during passive scattering proton therapy.

Yuanshui Zheng1, Wayne Newhauser, Jonas Fontenot, Phil Taddei, Radhe Mohan.   

Abstract

Stray radiation exposures are of concern for patients receiving proton radiotherapy and vary strongly with several treatment factors. The purposes of this study were to conservatively estimate neutron exposures for a contemporary passive scattering proton therapy system and to understand how they vary with treatment factors. We studied the neutron dose equivalent per therapeutic absorbed dose (H/D) as a function of treatment factors including proton energy, location in the treatment room, treatment field size, spread-out Bragg peak (SOBP) width and snout position using both Monte Carlo simulations and analytical modeling. The H/D value at the isocenter for a 250 MeV medium field size option was estimated to be 20 mSv Gy(-1). H/D values generally increased with the energy or penetration range, fell off sharply with distance from the treatment unit, decreased modestly with the aperture size, increased with the SOBP width and decreased with the snout distance from the isocenter. The H/D values from Monte Carlo simulations agreed well with experimental results from the literature. The analytical model predicted H/D values within 28% of those obtained in simulations; this value is within typical neutron measurement uncertainties.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17634645     DOI: 10.1088/0031-9155/52/15/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  32 in total

1.  An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle.

Authors:  Gabriel O Sawakuchi; Dragan Mirkovic; Luis A Perles; Narayan Sahoo; X Ron Zhu; George Ciangaru; Kazumichi Suzuki; Michael T Gillin; Radhe Mohan; Uwe Titt
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  An analytic model of neutron ambient dose equivalent and equivalent dose for proton radiotherapy.

Authors:  Rui Zhang; Angélica Pérez-Andújar; Jonas D Fontenot; Phillip J Taddei; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

3.  Contribution to Neutron Fluence and Neutron Absorbed Dose from Double Scattering Proton Therapy System Components.

Authors:  A Pérez-Andújar; W D Newhauser; P M Deluca
Journal:  Nucl Technol       Date:  2009-01-01

4.  Monte Carlo and analytical model predictions of leakage neutron exposures from passively scattered proton therapy.

Authors:  Angélica Pérez-Andújar; Rui Zhang; Wayne Newhauser
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

5.  Fan-beam intensity modulated proton therapy.

Authors:  Patrick Hill; David Westerly; Thomas Mackie
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

Review 6.  Assessment of the risk for developing a second malignancy from scattered and secondary radiation in radiation therapy.

Authors:  Harald Paganetti
Journal:  Health Phys       Date:  2012-11       Impact factor: 1.316

7.  Analytical model for out-of-field dose in photon craniospinal irradiation.

Authors:  Phillip J Taddei; Wassim Jalbout; Rebecca M Howell; Nabil Khater; Fady Geara; Kenneth Homann; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2013-10-08       Impact factor: 3.609

8.  Neutron production from beam-modifying devices in a modern double scattering proton therapy beam delivery system.

Authors:  Angélica Pérez-Andújar; Wayne D Newhauser; Paul M Deluca
Journal:  Phys Med Biol       Date:  2009-01-16       Impact factor: 3.609

9.  Assessment of the accuracy of an MCNPX-based Monte Carlo simulation model for predicting three-dimensional absorbed dose distributions.

Authors:  U Titt; N Sahoo; X Ding; Y Zheng; W D Newhauser; X R Zhu; J C Polf; M T Gillin; R Mohan
Journal:  Phys Med Biol       Date:  2008-07-31       Impact factor: 3.609

10.  Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault.

Authors:  Yuanshui Zheng; Wayne Newhauser; Eric Klein; Daniel Low
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.