Literature DB >> 17626146

Echocardiographic assessment of blood flow volume in the superior vena cava and descending aorta in the newborn infant.

A M Groves1, C A Kuschel, D B Knight, J R Skinner.   

Abstract

BACKGROUND: Clinical methods of assessing adequacy of the circulation are poor predictors of volume of blood flow in the newborn preterm. Doppler echocardiography can be used to assess perfusion at various sites in the circulation.
OBJECTIVE: To assess repeatability of measurement of volume of superior vena caval (SVC) and descending aortic (DAo) flow.
DESIGN: SVC and DAo flow volume were assessed four times in the first 48 h of postnatal life in a cohort of preterm (<31 weeks) infants. Within-observer and between-observer repeatability was assessed in a subgroup of preterm infants. Normative values were derived from 14 preterm infants who required <48 h respiratory support and 13 healthy term infants.
RESULTS: Within-observer repeatability coefficient was 30 ml/kg/min for quantification of SVC flow, and 2.2 cm for DAo stroke distance. Measurement of DAo diameter had poor repeatability. Between-observer repeatability appeared poorer than within-observer repeatability. The fifth centile for volume of SVC flow in healthy preterm infants was 55 ml/kg/min and 4.5 cm for DAo stroke distance.
CONCLUSIONS: Echocardiographic assessments of volume of SVC flow and velocity of DAo flow have similar within-observer repeatability to other neonatal haemodynamic measurements. Between-observer repeatability for both measurements was poor, reflecting the difficulty of standardising these novel techniques. In this small cohort of preterm infants, SVC flow volume <55 ml/kg/min and DAo stroke distance <4.5 cm represented low or borderline systemic perfusion in the first 48 h of postnatal life.

Entities:  

Mesh:

Year:  2007        PMID: 17626146     DOI: 10.1136/adc.2006.109512

Source DB:  PubMed          Journal:  Arch Dis Child Fetal Neonatal Ed        ISSN: 1359-2998            Impact factor:   5.747


  19 in total

1.  The diagnostic value of a single measurement of superior vena cava flow in the first 24 h of life in very preterm infants.

Authors:  James R Holberton; Sandra M Drew; Rintaro Mori; Kai König
Journal:  Eur J Pediatr       Date:  2012-05-26       Impact factor: 3.183

2.  Effects of delayed cord clamping in intrauterine growth-restricted neonates: a randomized controlled trial.

Authors:  Kanhu Charan Digal; Poonam Singh; Yash Srivastava; Jaya Chaturvedi; Amit Kumar Tyagi; Sriparna Basu
Journal:  Eur J Pediatr       Date:  2021-01-21       Impact factor: 3.183

3.  Hemodynamic Quality Improvement Bundle to Reduce the Use of Inotropes in Extreme Preterm Neonates.

Authors:  Sujith Kumar Reddy Gurram Venkata; Ankur Srivastava; Prashanth Murthy; James N Scott; Hussein Zein; Lara Leijser; Anirban Ghosh; Sarfaraz Momin; Sumesh Thomas; Khorshid Mohammad
Journal:  Paediatr Drugs       Date:  2022-04-26       Impact factor: 3.022

4.  Hemodynamic effects of delayed cord clamping in premature infants.

Authors:  Ross Sommers; Barbara S Stonestreet; William Oh; Abbot Laptook; Toby Debra Yanowitz; Christina Raker; Judith Mercer
Journal:  Pediatrics       Date:  2012-02-13       Impact factor: 7.124

5.  Cardiac blood flow measurements in stable full term small for gestational age neonates.

Authors:  Nishant Banait; Pradeep Suryawanshi; Nandini Malshe; Rema Nagpal; Sanjay Lalwani
Journal:  J Clin Diagn Res       Date:  2013-08-01

6.  Functional cardiac MRI in preterm and term newborns.

Authors:  Alan M Groves; Gaia Chiesa; Giuliana Durighel; Stephen T Goldring; Julie A Fitzpatrick; Sergio Uribe; Reza Razavi; Jo V Hajnal; A David Edwards
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2010-10-21       Impact factor: 5.747

7.  The methodology of Doppler-derived central blood flow measurements in newborn infants.

Authors:  Koert A de Waal
Journal:  Int J Pediatr       Date:  2012-01-16

Review 8.  Provision of respiratory support compared to no respiratory support before cord clamping for preterm infants.

Authors:  Michael P Meyer; Elizabeth Nevill; Maisie M Wong
Journal:  Cochrane Database Syst Rev       Date:  2018-03-08

9.  Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants.

Authors:  Benjamim Ficial; Anna E Finnemore; David J Cox; Kathryn M Broadhouse; Anthony N Price; Giuliana Durighel; Georgia Ekitzidou; Joseph V Hajnal; A David Edwards; Alan M Groves
Journal:  J Am Soc Echocardiogr       Date:  2013-09-26       Impact factor: 5.251

10.  End-organ saturations correlate with aortic blood flow estimates by echocardiography in the extremely premature newborn - an observational cohort study.

Authors:  Gabriel Altit; Shazia Bhombal; Valerie Y Chock
Journal:  BMC Pediatr       Date:  2021-07-12       Impact factor: 2.125

View more