Literature DB >> 17621229

Second-generation proximally coated titanium femoral component: minimum 7-year results.

Paul F Lachiewicz1, Elizabeth S Soileau, Paul Bryant.   

Abstract

It is unclear whether resurfacing or fully porous-coated or proximally coated stems are the best femoral components for young patients. First-generation proximally coated titanium fiber-metal femoral components had a high rate of failure. We prospectively followed 56 patients (70 hips) whom we believed were at high risk for loosening of a cemented femoral component; all patients were implanted with one second-generation proximally coated titanium femoral component. Ten patients (11 hips) died and three patients (four hips) were lost to minimum followup. Three models of titanium fiber-metal acetabular component were implanted with screws. Patients were clinically evaluated using the Harris hip score. We used standardized radiographs to assess fixation status and osteolysis. Forty-four patients (55 hips) with a mean age of 45 years were followed for a minimum of 7 years (mean, 10.5 years; range, 7-15 years). No femoral component had been revised for any reason. Bone ingrowth (spot welding) was seen in 41 hips (75%) and proximal femoral osteolysis in only four hips. Reoperations for polyethylene wear were performed in seven patients (12.7%) and two patients had liner exchange for recurrent dislocation. Even with an articulating surface with considerable polyethylene wear debris, these second-generation proximally coated titanium fiber-metal femoral components had a survival rate of 100% at a mean 10.5-year followup.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17621229     DOI: 10.1097/BLO.0b013e318137a167

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  3 in total

1.  Early Post-operative Periprosthetic Femur Fracture in the Presence of a Non-cemented Tapered Wedge Femoral Stem.

Authors:  H John Cooper; José A Rodriguez
Journal:  HSS J       Date:  2010-04-02

2.  In vivo testing of canine prosthetic femoral components with HA-Ti ladder-type coating on vacuum plasma-sprayed Ti substrate.

Authors:  Xian-Lin Zeng; Jing-Feng Li; Shu-Hua Yang; Qi-Xin Zheng; Zhen-Wei Zou
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-08-01

3.  Long-term follow-up results of a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels.

Authors:  Chang Wook Han; Ick Hwan Yang; Hye Yeon Lee; Chang Dong Han
Journal:  Yonsei Med J       Date:  2012-01       Impact factor: 2.759

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.