Literature DB >> 17620811

Imageless navigation for TKA increases implantation accuracy.

Arno Martin1, Othmar Wohlgenannt, Michael Prenn, Christian Oelsch, Archibald von Strempel.   

Abstract

Because we are performing TKAs on heavier, younger patients, greater stress is being put on the implants and is increasing the importance of implantation accuracy. We performed a prospective randomized study to compare the radiographic results and the 3-month clinical outcomes in 100 patients who had TKAs using an imageless navigation system with 100 patients treated using conventional implantation instruments. We measured component alignment by standard radiographs. Clinical outcomes were based on the Insall score, anterior knee pain, feeling of instability, and the step test. The mechanical axis of the limb was within 3 degrees varus/valgus in 92% of the patients who had navigated procedures versus 76% of patients who had conventional surgery. The tibial slope showed a rate of inaccuracy of 3 degrees or less for 98% of the patients in the navigated TKA group versus 80% of the patients in the conventional group. The surgical time was longer for navigated TKA than for the conventional procedure (88 +/- 16 versus 68 +/- 18 minutes, respectively). Clinical outcomes and postoperative blood loss were similar in both groups. The navigation system increased implantation accuracy but did not prevent outliers and did not solve the problems associated with identifying and obtaining accurate component rotation.

Entities:  

Mesh:

Year:  2007        PMID: 17620811     DOI: 10.1097/BLO.0b013e31804ea45f

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  21 in total

1.  Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies.

Authors:  Yaron S Brin; Vassilios S Nikolaou; Lawrence Joseph; David J Zukor; John Antoniou
Journal:  Int Orthop       Date:  2010-04-08       Impact factor: 3.075

2.  Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy.

Authors:  C Schnurr; J W P Michael; P Eysel; D P König
Journal:  Int Orthop       Date:  2007-12-22       Impact factor: 3.075

3.  Accuracy of side-cutting implantation instruments for total knee arthroplasty.

Authors:  Arno Martin; Mitchell B Sheinkop; Mary M Langhenry; Christian Oelsch; Mark Widemschek; Archibald von Strempel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-01-09       Impact factor: 4.342

4.  Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study.

Authors:  Mark Yaffe; Michael Luo; Nitin Goyal; Philip Chan; Anay Patel; Max Cayo; S David Stulberg
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-13       Impact factor: 2.924

5.  Influence of the anterior-posterior femoral translation on the range of motion in cruciate-retaining total knee arthroplasty.

Authors:  Shinya Yanagisawa; Naoki Sato; Takashi Ohsawa; Kenichi Saito; Masaki Shimizu; Kenji Takagishi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-06-22       Impact factor: 4.342

6.  [Cost analysis for navigation in knee endoprosthetics].

Authors:  O Cerha; S Kirschner; K-P Günther; J Lützner
Journal:  Orthopade       Date:  2009-12       Impact factor: 1.087

7.  Comparison of two minimally invasive implantation instrument-sets for total knee arthroplasty.

Authors:  Arno Martin; Mitchell B Sheinkop; Mary M Langhenry; Mark Widemschek; Thomas Benesch; Archibald von Strempel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-22       Impact factor: 4.342

Review 8.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

9.  Navigation-based femorotibial rotation pattern correlated with flexion angle after total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Hiroshi Sasaki; Koji Takayama; Tokio Matsuzaki; Katsumasa Tei; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-27       Impact factor: 4.342

10.  Accuracy of image-free navigation for severely deformed knees.

Authors:  Minoru Takasaki; Shuichi Matsuda; Shingo Fukagawa; Hiroaki Mitsuyasu; Hiromasa Miura; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-17       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.