Literature DB >> 17618136

Evaluation of a limited cone-beam volumetric imaging system: comparison with film radiography in detecting incipient proximal caries.

Ryoko Tsuchida1, Kazuyuki Araki, Tomohiro Okano.   

Abstract

OBJECTIVES: To assess the accuracy of a limited cone-beam volumetric imaging system in detecting incipient proximal caries. STUDY
DESIGN: Fifty extracted premolars were used. On 100 surfaces examined, 71 proximal carious lesions were found; 47 were limited to the enamel, and 24 penetrated into the dentin. A limited cone-beam volumetric imaging system (CBVI), 3D Accuitomo (J. Morita Mfg. Corp., Kyoto, Japan), was used. Insight films (Eastman Kodak, Rochester, NY) were used for comparison. Seven experienced oral radiologists determined the presence of lesions using a continuous rating scale. The area measure (Az) values were calculated from the receiver operating characteristic curve obtained for each modality and observer.
RESULTS: The mean Az-values were 0.63 +/- 0.02 for 3D Accuitomo and 0.63 +/- 0.03 for film. Analysis of variance showed no statistically significant difference between 3D Accuitomo and film.
CONCLUSIONS: A limited CBVI, 3D Accuitomo, could not enhance the accuracy in detecting proximal carious lesions.

Entities:  

Mesh:

Year:  2007        PMID: 17618136     DOI: 10.1016/j.tripleo.2007.02.028

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  20 in total

1.  Ex vivo comparison of Galileos cone beam CT and intraoral radiographs in detecting occlusal caries.

Authors:  S Rathore; D Tyndall; Jt Wright; E Everett
Journal:  Dentomaxillofac Radiol       Date:  2011-12-19       Impact factor: 2.419

Review 2.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

3.  Diagnostic accuracy of different imaging modalities in detection of proximal caries.

Authors:  B Senel; K Kamburoglu; O Uçok; S P Yüksel; T Ozen; H Avsever
Journal:  Dentomaxillofac Radiol       Date:  2010-12       Impact factor: 2.419

4.  Ex vivo evaluation of new 2D and 3D dental radiographic technology for detecting caries.

Authors:  Laurence Gaalaas; Donald Tyndall; André Mol; Eric T Everett; Ananta Bangdiwala
Journal:  Dentomaxillofac Radiol       Date:  2015-12-16       Impact factor: 2.419

5.  Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations.

Authors:  C Tomasi; E Bressan; B Corazza; S Mazzoleni; E Stellini; A Lith
Journal:  Dentomaxillofac Radiol       Date:  2011-05       Impact factor: 2.419

6.  Stationary intraoral digital tomosynthesis using a carbon nanotube X-ray source array.

Authors:  J Shan; A W Tucker; L R Gaalaas; G Wu; E Platin; A Mol; J Lu; O Zhou
Journal:  Dentomaxillofac Radiol       Date:  2015-06-19       Impact factor: 2.419

7.  Detection of cavitated approximal surfaces using cone beam CT and intraoral receptors.

Authors:  A Wenzel; E Hirsch; J Christensen; L H Matzen; G Scaf; M Frydenberg
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

8.  Performance of a photostimulable storage phosphor digital system with or without the sharpen filter and cone beam CT for detecting approximal enamel subsurface demineralization.

Authors:  M D F Belém; C P M Tabchoury; R I Ferreira-Santos; F C Groppo; F Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2013-02-14       Impact factor: 2.419

9.  The influence of amalgam fillings on the detection of approximal caries by cone beam CT: in vitro study.

Authors:  T Kulczyk; M Dyszkiewicz Konwińska; M Owecka; J Krzyżostaniak; A Surdacka
Journal:  Dentomaxillofac Radiol       Date:  2014-07-02       Impact factor: 2.419

10.  Effect of computer assistance on observer performance of approximal caries diagnosis using intraoral digital radiography.

Authors:  Kazuyuki Araki; Yukiko Matsuda; Kenji Seki; Tomohiro Okano
Journal:  Clin Oral Investig       Date:  2009-06-26       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.