Literature DB >> 17611851

Quantification of polyethylene degradation in mobile bearing knees: a retrieval analysis of the Anterior-Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee.

Alan M Kop1, Eric Swarts.   

Abstract

BACKGROUND: Routine qualitative observations of more than 850 polyethylene fixed and mobile bearings at our institution have noted minimal wear of mobile bearings. The APG mobile bearing is the most recent design variant of the LCS knee, allows multi-directional movement at the tibiofemoral articulation, and is posterior cruciate sparing. Even though it is difficult to perform, quantitative wear measurement is important in determining the likely longevity of new arthroplasty devices, and is especially relevant because of increasing numbers of new mobile bearing designs. PATIENTS AND METHODS: We analyzed 10 retrieved APG and 7 retrieved RP tibial bearings (De Puy) with a mean implantation period of 33 (9-70) months. We used coordinate-measuring techniques to quantitatively determine linear penetration, and optical and scanning electron microscopy to assess wear mechanisms qualitatively.
RESULTS: The mean total volume loss (superior and inferior articulations) of the APG and RP designs was 85 mm((3))/year and 77 mm((3))/year, respectively. Burnishing was the predominant wear mechanism, and to a lesser extent scratching, abrasion and pitting. Multidirectional scratching and abrasion were noted on the APG inserts inferiorly, whereas there was circumferential scratching on the RP inserts.
INTERPRETATION: Our short-term results for the APG and RP mobile bearing designs are similar and compare more than favorably with reported values for fixed-bearing designs. However, increased backside wear due to multidirectional movement may predispose the APG design to greater wear in the long term.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17611851     DOI: 10.1080/17453670710013942

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  13 in total

1.  Knee wear measured in retrievals: a polished tray reduces insert wear.

Authors:  Daniel J Berry; John H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  In vitro quantification of wear in tibial inserts using microcomputed tomography.

Authors:  Matthew G Teeter; Douglas D R Naudie; David D McErlain; Jan-M Brandt; Xunhua Yuan; Steven J Macdonald; David W Holdsworth
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

3.  Wear damage in mobile-bearing TKA is as severe as that in fixed-bearing TKA.

Authors:  Natalie H Kelly; Rose H Fu; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

4.  How do CAD models compare with reverse engineered manufactured components for use in wear analysis?

Authors:  Matthew G Teeter; Douglas D R Naudie; Robert B Bourne; David W Holdsworth
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

Review 5.  Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis.

Authors:  Toby O Smith; Farshid Ejtehadi; Rachel Nichols; Leigh Davies; Simon T Donell; Caroline B Hing
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-09-25       Impact factor: 4.342

Review 6.  Is there any superiority in the clinical outcome of mobile-bearing knee prosthesis designs compared to fixed-bearing total knee prosthesis designs in the treatment of osteoarthritis of the knee joint? A review of the literature.

Authors:  H Van der Bracht; G Van Maele; P Verdonk; K F Almqvist; R Verdonk; M Freeman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-30       Impact factor: 4.342

7.  Comparison of patellar retention versus resurfacing in LCS mobile-bearing total knee arthroplasty.

Authors:  Bo-Hyun Hwang; Ick-Hwan Yang; Chang-Dong Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-01       Impact factor: 4.342

8.  Can microcomputed tomography measure retrieved polyethylene wear? Comparing fixed-bearing and rotating-platform knees.

Authors:  Charles A Engh; Rebecca L Zimmerman; Robert H Hopper; Gerard A Engh
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

9.  Improved early clinical outcomes of RP/PS mobile-bearing total knee arthroplasties.

Authors:  Tae Kyun Kim; Hyung Joon Cho; Yeon Gwi Kang; Sung Ju Kim; Chong Bum Chang
Journal:  Clin Orthop Relat Res       Date:  2009-03-19       Impact factor: 4.176

10.  Early clinical outcomes of floating platform mobile-bearing TKA: longitudinal comparison with fixed-bearing TKA.

Authors:  Tae Kyun Kim; Chong Bum Chang; Yeon Gwi Kang; Byung June Chung; Hyung Joon Cho; Sang Cheol Seong
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-11-28       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.