Literature DB >> 28824965

Hybrid Solutions for the Surgical Treatment of Multilevel Degenerative Cervical Disk Disease.

Stefan Alexander König1, Sebastian Ranguis2, Uwe Spetzger1.   

Abstract

Background In different stages of cervical degenerative disk disease, the combination of dynamic and nondynamic implants may be considered. The aim of this study was to investigate the applicability of criteria to assist decision making in these cases. Methods Thirty patients with spondylotic cervical radiculopathy and a coincidence of soft disk and hard disk herniation were surgically treated with a hybrid solution (combination of total disk replacement and cage fusion). The control group included 32 patients who underwent two-level cage fusion. Pre- and postoperative Japanese Orthopaedic Association (JOA) scores and range of motion (ROM) were compared. Results Twenty-three patients underwent two-level hybrid solution and 7 underwent three-level treatment. The most frequent solution (n = 13) was a combination of a dynamic implant at C5-C6 and a nondynamic implant at C6-C7. The mean JOA score improved from 13.9 to 15.6 points after surgery (mean deviation [MD] 1.6, 95% confidence interval [CI] 2.1 to 1.2, p < 0.001). ROM showed a slight trend to increase (MD 0.8, 95% CI -0.9 to 2.6, p = 0.193). In the control group, the mean JOA score improved from 13.3 to 15.1 points after surgery (MD 1.4, 95% CI 2.1 to 1.2, p < 0.001). The comparison of the postoperative JOA scores and recovery rates between the hybrid treatment group and the control group did not show significant differences. Conclusions In cases of coincident soft and hard degenerative cervical disk disease at adjacent levels, the combination of a disk prosthesis and a nondynamic implant is a safe and effective treatment option and an alternative to multilevel fusion.

Entities:  

Keywords:  cervical spine; degeneration; disk replacement; fusion; hybrid surgery

Year:  2015        PMID: 28824965      PMCID: PMC5530620          DOI: 10.1055/s-0035-1567876

Source DB:  PubMed          Journal:  Surg J (N Y)        ISSN: 2378-5128


  24 in total

1.  Sagittal alignment after single cervical disc arthroplasty.

Authors:  Patrick Guérin; Ibrahim Obeid; Olivier Gille; Anouar Bourghli; Stéphane Luc; Vincent Pointillart; Jean-Marc Vital
Journal:  J Spinal Disord Tech       Date:  2012-02

2.  Biomechanical analysis of the range of motion after placement of a two-level cervical ProDisc-C versus hybrid construct.

Authors:  Bo Young Cho; Jesse Lim; Hong Bo Sim; Jon Park
Journal:  Spine (Phila Pa 1976)       Date:  2010-09-01       Impact factor: 3.468

3.  Disc replacement adjacent to cervical fusion: a biomechanical comparison of hybrid construct versus two-level fusion.

Authors:  Michael J Lee; Mark Dumonski; Frank M Phillips; Leonard I Voronov; Susan M Renner; Gerard Carandang; Robert M Havey; Avinash G Patwardhan
Journal:  Spine (Phila Pa 1976)       Date:  2011-11-01       Impact factor: 3.468

4.  Analysis of in vivo kinematics of 3 different cervical devices: Bryan disc, ProDisc-C, and Prestige LP disc.

Authors:  Izabela Kowalczyk; Bruno C R Lazaro; Marie Fink; Doron Rabin; Neil Duggal
Journal:  J Neurosurg Spine       Date:  2011-09-09

Review 5.  Parameters that effect spine biomechanics following cervical disc replacement.

Authors:  Vijay K Goel; Ahmad Faizan; Vivek Palepu; Sanghita Bhattacharya
Journal:  Eur Spine J       Date:  2011-05-20       Impact factor: 3.134

6.  Two-level noncontiguous versus three-level anterior cervical discectomy and fusion: a biomechanical comparison.

Authors:  Michael A Finn; Mical M Samuelson; Frank Bishop; Kent N Bachus; Darrel S Brodke
Journal:  Spine (Phila Pa 1976)       Date:  2011-03-15       Impact factor: 3.468

7.  Multilevel cervical arthroplasty with artificial disc replacement.

Authors:  Mario J Cardoso; Michael K Rosner
Journal:  Neurosurg Focus       Date:  2010-05       Impact factor: 4.047

8.  Cervical hybrid arthroplasty with 2 unique fusion techniques.

Authors:  Mario J Cardoso; Audra Mendelsohn; Michael K Rosner
Journal:  J Neurosurg Spine       Date:  2011-04-01

9.  Remodeling of adjacent spinal alignments following cervical arthroplasty and anterior discectomy and fusion.

Authors:  Sung Bae Park; Tae-Ahn Jahng; Chun Kee Chung
Journal:  Eur Spine J       Date:  2011-08-30       Impact factor: 3.134

10.  [Total cervical disk replacement--implant-specific approaches: keel implant (Prodisc-C intervertebral disk prosthesis)].

Authors:  Andreas Korge; Christoph J Siepe; Franziska Heider; H Michael Mayer
Journal:  Oper Orthop Traumatol       Date:  2010-11       Impact factor: 1.154

View more
  2 in total

1.  Cervical balance and clinical outcomes in cervical spondylotic myelopathy treated by three-level anterior cervical discectomy and fusion and hybrid cervical surgery: A CONSORT-compliant study with minimum follow-up period of 5 years.

Authors:  Fanqi Meng; Shuai Xu; Yan Liang; Zhenqi Zhu; Kaifeng Wang; Haiying Liu
Journal:  Medicine (Baltimore)       Date:  2021-05-07       Impact factor: 1.889

2.  Exploration on sagittal alignment and clinical outcomes after consecutive three-level hybrid surgery and anterior cervical discectomy and fusion: a minimum of a 5-year follow-up.

Authors:  Shuai Xu; Yan Liang; Guanjie Yu; Zhenqi Zhu; Kaifeng Wang; Haiying Liu
Journal:  J Orthop Surg Res       Date:  2020-02-26       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.