Literature DB >> 17601650

Physical properties of tissues relevant to arterial ultrasound imaging and blood velocity measurement.

Peter R Hoskins1.   

Abstract

A review was undertaken of physical phenomena and the values of associated physical quantities relevant to arterial ultrasound imaging and measurement. Arteries are multilayered anisotropic structures. However, the requirement to obtain elasticity measurements from the data available using ultrasound imaging necessitates the use of highly simplified constitutive models involving Young's modulus, E. Values of E are reported for healthy arteries and for the constituents of diseased arteries. It is widely assumed that arterial blood flow is Newtonian. However, recent studies suggest that non-Newtonian behavior has a strong influence on arterial flow, and the balance of published evidence suggests that non-Newtonian behavior is associated primarily with red cell deformation rather than with aggregation. Hence, modeling studies should account for red cell deformation and the shear thinning effect that this produces. Published literature in healthy adults gives an average hematocrit and high-shear viscosity of 0.44 +/- 0.03 and 3.9 +/- 0.6 mPa.s, respectively. Published data on the acoustic properties of arteries and blood is sufficiently consistent between papers to allow compilation and derivation of best-fit equations summarizing the behavior across a wide frequency range, which then may be used in future modeling studies. Best-fit equations were derived for the attenuation coefficient vs. frequency in whole arteries (R(2) = 0.995), plasma (R(2) = 0.963) and blood with hematocrit near 45% (R(2) = 0.999), and for the backscatter coefficient vs. frequency from blood with hematocrit near 45% (R(2) = 0.958).

Mesh:

Year:  2007        PMID: 17601650     DOI: 10.1016/j.ultrasmedbio.2007.04.020

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  10 in total

1.  A tissue phantom for visualization and measurement of ultrasound-induced cavitation damage.

Authors:  Adam D Maxwell; Tzu-Yin Wang; Lingqian Yuan; Alexander P Duryea; Zhen Xu; Charles A Cain
Journal:  Ultrasound Med Biol       Date:  2010-10-28       Impact factor: 2.998

2.  Efficacy of histotripsy combined with rt-PA in vitro.

Authors:  Kenneth B Bader; Kevin J Haworth; Himanshu Shekhar; Adam D Maxwell; Tao Peng; David D McPherson; Christy K Holland
Journal:  Phys Med Biol       Date:  2016-06-29       Impact factor: 3.609

3.  3D-Printed Tissue-Mimicking Phantoms for Medical Imaging and Computational Validation Applications.

Authors:  Aidan J Cloonan; Danial Shahmirzadi; Ronny X Li; Barry J Doyle; Elisa E Konofagou; Tim M McGloughlin
Journal:  3D Print Addit Manuf       Date:  2014-03-01       Impact factor: 5.449

4.  FloWave.US: validated, open-source, and flexible software for ultrasound blood flow analysis.

Authors:  Crystal L Coolbaugh; Emily C Bush; Charles F Caskey; Bruce M Damon; Theodore F Towse
Journal:  J Appl Physiol (1985)       Date:  2016-08-11

5.  Modeling tissue-selective cavitation damage.

Authors:  Lauren Mancia; Eli Vlaisavljevich; Nyousha Yousefi; Mauro Rodriguez; Timothy J Ziemlewicz; Fred T Lee; David Henann; Christian Franck; Zhen Xu; Eric Johnsen
Journal:  Phys Med Biol       Date:  2019-11-15       Impact factor: 3.609

6.  Development of a flexible implantable sensor for postoperative monitoring of blood flow.

Authors:  Jonathan M Cannata; Thomas Chilipka; Hao-Chung Yang; Sukgu Han; Sung W Ham; Vincent L Rowe; Fred A Weaver; K Kirk Shung; David Vilkomerson
Journal:  J Ultrasound Med       Date:  2012-11       Impact factor: 2.153

7.  Noninvasive thrombolysis using pulsed ultrasound cavitation therapy - histotripsy.

Authors:  Adam D Maxwell; Charles A Cain; Alexander P Duryea; Lingqian Yuan; Hitinder S Gurm; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2009-10-24       Impact factor: 2.998

8.  Acoustic radiation force impulse imaging of vulnerable plaques: a finite element method parametric analysis.

Authors:  Joshua R Doherty; Douglas M Dumont; Gregg E Trahey; Mark L Palmeri
Journal:  J Biomech       Date:  2012-10-31       Impact factor: 2.712

9.  Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models.

Authors:  Anderson Chun On Tsang; Simon Sui Man Lai; Wai Choi Chung; Abraham Yik Sau Tang; Gilberto Ka Kit Leung; Alexander Kai Kei Poon; Alfred Cheuk Hang Yu; Kwok Wing Chow
Journal:  Ultrasonography       Date:  2015-01-31

10.  Thermal characteristics of non-biological vessel phantoms for treatment of varicose veins using high-intensity focused ultrasound.

Authors:  Mi-Sun Kim; Ju-Young Kim; Si-Cheol Noh; Heung-Ho Choi
Journal:  PLoS One       Date:  2017-04-06       Impact factor: 3.240

  10 in total