Literature DB >> 27516540

FloWave.US: validated, open-source, and flexible software for ultrasound blood flow analysis.

Crystal L Coolbaugh1, Emily C Bush2, Charles F Caskey3, Bruce M Damon4, Theodore F Towse5.   

Abstract

Automated software improves the accuracy and reliability of blood velocity, vessel diameter, blood flow, and shear rate ultrasound measurements, but existing software offers limited flexibility to customize and validate analyses. We developed FloWave.US-open-source software to automate ultrasound blood flow analysis-and demonstrated the validity of its blood velocity (aggregate relative error, 4.32%) and vessel diameter (0.31%) measures with a skeletal muscle ultrasound flow phantom. Compared with a commercial, manual analysis software program, FloWave.US produced equivalent in vivo cardiac cycle time-averaged mean (TAMean) velocities at rest and following a 10-s muscle contraction (mean bias <1 pixel for both conditions). Automated analysis of ultrasound blood flow data was 9.8 times faster than the manual method. Finally, a case study of a lower extremity muscle contraction experiment highlighted the ability of FloWave.US to measure small fluctuations in TAMean velocity, vessel diameter, and mean blood flow at specific time points in the cardiac cycle. In summary, the collective features of our newly designed software-accuracy, reliability, reduced processing time, cost-effectiveness, and flexibility-offer advantages over existing proprietary options. Further, public distribution of FloWave.US allows researchers to easily access and customize code to adapt ultrasound blood flow analysis to a variety of vascular physiology applications.
Copyright © 2016 the American Physiological Society.

Keywords:  Doppler; edge detection; flow-mediated dilation; regional blood flow; wave tracking

Mesh:

Year:  2016        PMID: 27516540      PMCID: PMC5142308          DOI: 10.1152/japplphysiol.00819.2015

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  38 in total

Review 1.  Assessment of flow-mediated dilation in humans: a methodological and physiological guideline.

Authors:  Dick H J Thijssen; Mark A Black; Kyra E Pyke; Jaume Padilla; Greg Atkinson; Ryan A Harris; Beth Parker; Michael E Widlansky; Michael E Tschakovsky; Daniel J Green
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-10-15       Impact factor: 4.733

2.  Conduit artery constriction mediated by low flow a novel noninvasive method for the assessment of vascular function.

Authors:  Tommaso Gori; Saverio Dragoni; Monica Lisi; Giuseppe Di Stolfo; Serena Sonnati; Massimo Fineschi; John D Parker
Journal:  J Am Coll Cardiol       Date:  2008-05-20       Impact factor: 24.094

3.  Real-time B-mode ultrasound quality control test procedures. Report of AAPM Ultrasound Task Group No. 1.

Authors:  M M Goodsitt; P L Carson; S Witt; D L Hykes; J M Kofler
Journal:  Med Phys       Date:  1998-08       Impact factor: 4.071

4.  Quantitative analysis of the postcontractile blood-oxygenation-level-dependent (BOLD) effect in skeletal muscle.

Authors:  Theodore F Towse; Jill M Slade; Jeffrey A Ambrose; Mark C DeLano; Ronald A Meyer
Journal:  J Appl Physiol (1985)       Date:  2011-02-17

5.  A computational approach to edge detection.

Authors:  J Canny
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1986-06       Impact factor: 6.226

6.  New methods for arterial diameter measurement from B-mode images.

Authors:  R W Stadler; W C Karl; R S Lees
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

7.  Validation of an automated method for assessing brachial artery endothelial dysfunction.

Authors:  G B John Mancini; Eunice Yeoh; David Abbott; Sammy Chan
Journal:  Can J Cardiol       Date:  2002-03       Impact factor: 5.223

8.  Comparison of two automatic methods for the assessment of brachial artery flow-mediated dilation.

Authors:  Francesco Faita; Stefano Masi; Stavros Loukogeorgakis; Vincenzo Gemignani; Mike Okorie; Elisabetta Bianchini; Marietta Charakida; Marcello Demi; Lorenzo Ghiadoni; John Eric Deanfield
Journal:  J Hypertens       Date:  2011-01       Impact factor: 4.844

9.  Automated ultrasonic measurement of human arteries for the determination of endothelial function.

Authors:  M Preik; T Lauer; C Heiss; S Tabery; B E Strauer; M Kelm
Journal:  Ultraschall Med       Date:  2000-10       Impact factor: 6.548

10.  Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis.

Authors:  D S Celermajer; K E Sorensen; V M Gooch; D J Spiegelhalter; O I Miller; I D Sullivan; J K Lloyd; J E Deanfield
Journal:  Lancet       Date:  1992-11-07       Impact factor: 79.321

View more
  8 in total

1.  Hot head-out water immersion does not acutely alter dynamic cerebral autoregulation or cerebrovascular reactivity to hypercapnia.

Authors:  Morgan L Worley; Emma L Reed; Paul J Kueck; Jacqueline Dirr; Nathan Klaes; Zachary J Schlader; Blair D Johnson
Journal:  Temperature (Austin)       Date:  2021-03-19

2.  Seven days of ischemic preconditioning augments hypoxic exercise ventilation and muscle oxygenation in recreationally trained males.

Authors:  Afton D Seeley; Aaron R Caldwell; Lawrence P Cahalin; Soyeon Ahn; Arlette C Perry; Brian Arwari; Kevin A Jacobs
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2022-08-15       Impact factor: 3.210

Review 3.  Assessment of resistance vessel function in human skeletal muscle: guidelines for experimental design, Doppler ultrasound, and pharmacology.

Authors:  Jacqueline K Limberg; Darren P Casey; Joel D Trinity; Wayne T Nicholson; D Walter Wray; Michael E Tschakovsky; Daniel J Green; Ylva Hellsten; Paul J Fadel; Michael J Joyner; Jaume Padilla
Journal:  Am J Physiol Heart Circ Physiol       Date:  2019-12-30       Impact factor: 4.733

4.  Role of Exercise in Vascular Function and Inflammatory Profile in Age-Related Obesity.

Authors:  Anna Pedrinolla; Massimo Venturelli; Emine Kirmizi; Federica Moschetta; Monica Zardini; Doriana Rudi; Elisabetta Bacchi; Federico Schena; Paolo Moghetti; Massimo Lanza
Journal:  J Immunol Res       Date:  2018-10-28       Impact factor: 4.818

5.  Defining Coronary Flow Patterns: Comprehensive Automation of Transthoracic Doppler Coronary Blood Flow.

Authors:  Ian L Sunyecz; Patricia E McCallinhart; Kishan U Patel; Michael R McDermott; Aaron J Trask
Journal:  Sci Rep       Date:  2018-11-22       Impact factor: 4.379

6.  Exercise training improves vascular function in patients with Alzheimer's disease.

Authors:  Anna Pedrinolla; Massimo Venturelli; Cristina Fonte; Stefano Tamburin; Angela Di Baldassarre; Fabio Naro; Valentina Varalta; Gaia Giuriato; Barbara Ghinassi; Ettore Muti; Nicola Smania; Federico Schena
Journal:  Eur J Appl Physiol       Date:  2020-07-30       Impact factor: 3.078

7.  Intra-rater reliability of leg blood flow during dynamic exercise using Doppler ultrasound.

Authors:  Sachin B Amin; Hendrik Mugele; Florian E Dobler; Kyohei Marume; Jonathan P Moore; Justin S Lawley
Journal:  Physiol Rep       Date:  2021-10

8.  Ultrasound Based Computational Fluid Dynamics Assessment of Brachial Artery Wall Shear Stress in Preeclamptic Pregnancy.

Authors:  Ryan J Pewowaruk; Jenna Racine; J Igor Iruretagoyena; Alejandro Roldán-Alzate
Journal:  Cardiovasc Eng Technol       Date:  2020-10-06       Impact factor: 2.305

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.