Literature DB >> 17595956

Ultrahigh-pressure liquid chromatography using a 1-mm id column packed with 1.5-microm porous particles.

Jason A Anspach1, Todd D Maloney, Luis A Colón.   

Abstract

The evolution of chromatography has led to the reduction in the size of the packing materials used to fabricate HPLC columns. The increase in the backpressure required has led to this technique being referred to as ultrahigh-pressure liquid chromatography (UHPLC) when the column backpressure exceeds 10000 psi (approximately 700 bar). Until recently, columns packed with sub-2-microm materials have generally fitted into two classes; either short (less than 5 cm) columns designed for use on traditional HPLC systems at pressures less than 5000 psi (350 bar), or capillary columns (inner diameters less than 100 microm). By using packing materials with diameters <2 microm to fabricate UHPLC columns, there is an increase in efficiency and a decrease in the analysis time that are directly proportional to the size of the packing material. In order to realize and exploit the increase in efficiency, however, the columns must maintain lengths typically associated with analytical columns (15-25 cm). We have packed 1 mm diameter, 150 mm in length columns with 1.5 microm packing material, and evaluated their performance in UHPLC. The pressure required to achieve optimum linear velocities in plots of plate height versus linear velocity was in the vicinity of 1104 bar (16000 psi). The 1.5 microm particle-packed column was compared with the more traditional 150 mm long analytical columns packed with 3 microm materials. This column showed an efficiency that was approximately twice that observed with the 3 microm packed column and a concomitant reduction in the analysis time, theoretically predicted.

Mesh:

Year:  2007        PMID: 17595956     DOI: 10.1002/jssc.200600535

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  5 in total

1.  Liquid chromatography above 20,000 PSI.

Authors:  Matthew J Sorensen; Brady G Anderson; Robert T Kennedy
Journal:  Trends Analyt Chem       Date:  2020-01-21       Impact factor: 12.296

2.  Rapid catalyst screening by a continuous-flow microreactor interfaced with ultra-high-pressure liquid chromatography.

Authors:  Hui Fang; Qing Xiao; Fanghui Wu; Paul E Floreancig; Stephen G Weber
Journal:  J Org Chem       Date:  2010-08-20       Impact factor: 4.354

3.  Repeatability of gradient ultrahigh pressure liquid chromatography-tandem mass spectrometry methods in instrument-controlled thermal environments.

Authors:  James P Grinias; Jenny-Marie T Wong; Robert T Kennedy
Journal:  J Chromatogr A       Date:  2016-07-18       Impact factor: 4.759

Review 4.  Metaproteomics: harnessing the power of high performance mass spectrometry to identify the suite of proteins that control metabolic activities in microbial communities.

Authors:  Robert L Hettich; Chongle Pan; Karuna Chourey; Richard J Giannone
Journal:  Anal Chem       Date:  2013-03-21       Impact factor: 6.986

5.  Phosphopeptide enrichment with TiO2-modified membranes and investigation of tau protein phosphorylation.

Authors:  Yu-Jing Tan; Dexin Sui; Wei-Han Wang; Min-Hao Kuo; Gavin E Reid; Merlin L Bruening
Journal:  Anal Chem       Date:  2013-05-28       Impact factor: 6.986

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.