Literature DB >> 27457561

Repeatability of gradient ultrahigh pressure liquid chromatography-tandem mass spectrometry methods in instrument-controlled thermal environments.

James P Grinias1, Jenny-Marie T Wong1, Robert T Kennedy2.   

Abstract

The impact of viscous friction on eluent temperature and column efficiency in liquid chromatography is of renewed interest as the need for pressures exceeding 1000bar to use with columns packed with sub-2μm particles has grown. One way the development of axial and radial temperature gradients that arise due to viscous friction can be affected is by the thermal environment the column is placed in. In this study, a new column oven integrated into an ultrahigh pressure liquid chromatograph that enables both still-air and forced-air operating modes is investigated to find the magnitude of the effect of the axial thermal gradient that forms in 2.1×100mm columns packed with sub-2μm particles in these modes. Temperature increases of nearly 30K were observed when the generated power of the column exceeded 25W/m. The impact of the heating due to viscous friction on the repeatability of peak capacity, elution time, and peak area ratio to an internal standard for a gradient UHPLC-MS/MS method to analyze neurotransmitters was found to be limited. This result indicates that high speed UHPLC-MS/MS gradient methods under conditions of high viscous friction may be possible without the negative effects typically observed with isocratic separations under similar conditions.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Column oven; Gradient liquid chromatography; Mass spectrometry; Neurochemistry; UHPLC; Viscous friction

Mesh:

Substances:

Year:  2016        PMID: 27457561      PMCID: PMC4981509          DOI: 10.1016/j.chroma.2016.07.043

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  53 in total

1.  High-speed liquid chromatography by simultaneous optimization of temperature and eluent composition.

Authors:  Jonathan D Thompson; Peter W Carr
Journal:  Anal Chem       Date:  2002-08-15       Impact factor: 6.986

Review 2.  Can the theory of gradient liquid chromatography be useful in solving practical problems?

Authors:  Pavel Jandera
Journal:  J Chromatogr A       Date:  2006-06-19       Impact factor: 4.759

3.  Ultrahigh-pressure liquid chromatography using a 1-mm id column packed with 1.5-microm porous particles.

Authors:  Jason A Anspach; Todd D Maloney; Luis A Colón
Journal:  J Sep Sci       Date:  2007-05       Impact factor: 3.645

4.  Influence of viscous friction heating on the efficiency of columns operated under very high pressures.

Authors:  Fabrice Gritti; Michel Martin; Georges Guiochon
Journal:  Anal Chem       Date:  2009-05-01       Impact factor: 6.986

5.  Investigation of the validity of the kinetic plot method to predict the performance of coupled column systems operated at very high pressures under different thermal conditions.

Authors:  Deirdre Cabooter; François Lestremau; André de Villiers; Ken Broeckhoven; Frédéric Lynen; Pat Sandra; Gert Desmet
Journal:  J Chromatogr A       Date:  2009-03-05       Impact factor: 4.759

6.  Practical assessment of frictional heating effects and thermostat design on the performance of conventional (3 microm and 5 microm) columns in reversed-phase high-performance liquid chromatography.

Authors:  Morgane M Fallas; Mark R Hadley; David V McCalley
Journal:  J Chromatogr A       Date:  2009-03-13       Impact factor: 4.759

7.  Some practical comparisons of the efficiency and overloading behaviour of sub-2 μm porous and sub-3 μm shell particles in reversed-phase liquid chromatography.

Authors:  David V McCalley
Journal:  J Chromatogr A       Date:  2011-03-04       Impact factor: 4.759

8.  Realization and potential advantages of gradient separations performed under steady state temperature regime.

Authors:  Fabrice Gritti; Georges Guiochon
Journal:  J Chromatogr A       Date:  2013-04-02       Impact factor: 4.759

9.  Achieving quasi-adiabatic thermal environment to maximize resolution power in very high-pressure liquid chromatography: Theory, models, and experiments.

Authors:  Fabrice Gritti; Martin Gilar; Joseph A Jarrell
Journal:  J Chromatogr A       Date:  2016-03-28       Impact factor: 4.759

Review 10.  High-speed high-performance liquid chromatography of peptides and proteins.

Authors:  H Chen; C Horváth
Journal:  J Chromatogr A       Date:  1995-06-23       Impact factor: 4.759

View more
  1 in total

1.  Small molecules released from islets of Langerhans determined by liquid chromatography - mass spectrometry.

Authors:  Emmanuel O Ogunkunle; Matthew J Donohue; Daniel J Steyer; Damilola I Adeoye; Wesley J Eaton; Michael G Roper
Journal:  Anal Methods       Date:  2022-06-01       Impact factor: 3.532