Literature DB >> 17587296

Reproducibility of DIAGNOdent 2095 and DIAGNOdent Pen measurements: results from an in vitro study on occlusal sites.

Jan Kühnisch1, Katharina Bücher, Volkmar Henschel, Reinhard Hickel.   

Abstract

The aim of this in vitro study was to investigate the intra- and interdevice reproducibility of the DIAGNOdent 2095 (DD2095) and the new DIAGNOdent Pen (DDPen) on non-cavitated occlusal caries sites. Altogether, 241 sites on 90 molars were inspected twice with both devices and by four examiners. The intra/interdevice reproducibilities were assessed by means of the intraclass correlation coefficient (ICC) as well as by the range of the 95% limits of agreement of Bland & Altman. Additionally, a linear mixed-effects model was fitted with fixed effects for the visual scores and the devices used and random effects for occlusal sites and examiners within each measurement site. In result, the following values were determined for the intradevice reproducibility: DD2095: ICC 0.89, range 42.3; and DDPen: ICC 0.88, range 49.3. The interdevice reproducibility was found to be in the same order of magnitude (ICC 0.82, range 53.7). The comparison between both devices indicated significantly lower mean values for the DDPen. The estimates of the linear model show that there is a high variation between the sites that cannot be explained by the fixed effects. In conclusion, both devices showed an imperfect reproducibility, which indicate the usage as adjunct tool only in clinical practice.

Entities:  

Mesh:

Year:  2007        PMID: 17587296     DOI: 10.1111/j.1600-0722.2007.00441.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  10 in total

1.  A novel LED-based device for occlusal caries detection.

Authors:  Ali Murat Aktan; Mehmet Ata Cebe; Mehmet Ertuğrul Ciftçi; Emine Sirin Karaarslan
Journal:  Lasers Med Sci       Date:  2011-11-13       Impact factor: 3.161

2.  Performance of laser fluorescence devices, visual and radiographic examination for the detection of occlusal caries in primary molars.

Authors:  Klaus W Neuhaus; Jonas Almeida Rodrigues; Isabel Hug; Herman Stich; Adrian Lussi
Journal:  Clin Oral Investig       Date:  2010-05-27       Impact factor: 3.573

3.  Influence of moisture and plaque on the performance of a laser fluorescence device in detecting caries lesions in primary teeth.

Authors:  Daniela G Bittar; Thaís Gimenez; Caroline C Morais; Monique S De Benedetto; Mariana M Braga; Fausto Medeiros Mendes
Journal:  Lasers Med Sci       Date:  2011-11-25       Impact factor: 3.161

4.  Comparing the reliability of a new fluorescence camera with conventional laser fluorescence devices in detecting caries lesions in occlusal and smooth surfaces of primary teeth.

Authors:  Monique Saveriano De Benedetto; Caroline Carvalho Morais; Tatiane Fernandes Novaes; Jonas de Almeida Rodrigues; Mariana Minatel Braga; Fausto Medeiros Mendes
Journal:  Lasers Med Sci       Date:  2010-02-16       Impact factor: 3.161

5.  Traditional and novel methods for occlusal caries detection: performance on primary teeth.

Authors:  J F Souza; T Boldieri; M B Diniz; J A Rodrigues; A Lussi; R C L Cordeiro
Journal:  Lasers Med Sci       Date:  2012-07-06       Impact factor: 3.161

6.  Assessment of a new infrared laser transillumination technology (808 nm) for the detection of occlusal caries-an in vitro study.

Authors:  D G Bussaneli; M Restrepo; T Boldieri; H Pretel; M W Mancini; L Santos-Pinto; R C L Cordeiro
Journal:  Lasers Med Sci       Date:  2014-12-31       Impact factor: 3.161

7.  In vitro comparison of laser fluorescence performance with visual examination for detection of occlusal caries in permanent and primary molars.

Authors:  Jonas A Rodrigues; Michele B Diniz; Erika B Josgrilberg; Rita C L Cordeiro
Journal:  Lasers Med Sci       Date:  2008-03-29       Impact factor: 3.161

8.  Development, methodology and potential of the new Universal Visual Scoring System (UniViSS) for caries detection and diagnosis.

Authors:  Jan Kühnisch; Inka Goddon; Susanne Berger; Helga Senkel; Katharina Bücher; Thomas Oehme; Reinhard Hickel; Roswitha Heinrich-Weltzien
Journal:  Int J Environ Res Public Health       Date:  2009-09-23       Impact factor: 3.390

Review 9.  Fluorescence-based methods for detecting caries lesions: systematic review, meta-analysis and sources of heterogeneity.

Authors:  Thais Gimenez; Mariana Minatel Braga; Daniela Procida Raggio; Chris Deery; David N Ricketts; Fausto Medeiros Mendes
Journal:  PLoS One       Date:  2013-04-04       Impact factor: 3.240

10.  Treatment of various degrees of white spot lesions using resin infiltration-in vitro study.

Authors:  Bassant A Abbas; Eiman S Marzouk; Abbas R Zaher
Journal:  Prog Orthod       Date:  2018-08-06       Impact factor: 2.750

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.