Literature DB >> 12454188

Evaluation of a plastic nonvented aerobic blood culture bottle for use with the BacT/ALERT microbial detection system.

J W Snyder1, G K Munier, G D Bostic, P S Bozigar, R Hanna.   

Abstract

The current BacT/ALERT SA (BTA SA) aerobic blood culture bottle is made from glass, does not require venting, and contains a liquid emulsion sensor (LES). Its performance has been shown to be equivalent to that of the vented standard aerobic culture bottle. A further-improved version of the BTA SA bottle, designated the BacT/ALERT plastic SA (BTA PSA) culture bottle, is made from clear plastic to prevent breakage, does not require venting, and contains a modified LES (LES 2) to reduce the possibility of false positives. The BTA PSA provides a practical alternative to the current glass version of this bottle. The plastic bottle is also comparable to the current glass bottle in transparency and growth performance and additionally minimizes the exposure to infectious agents due to glass bottle breakage.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12454188      PMCID: PMC154602          DOI: 10.1128/JCM.40.12.4757-4759.2002

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  3 in total

1.  Clinical comparison of nonvented aerobic BacT/Alert blood culture bottle and standard aerobic bottle for detection of microorganisms in blood.

Authors:  J W Snyder; K S Benzing; G K Munier; G D Bostic; P S Bozigar; R Hanna; M J Zervos
Journal:  J Clin Microbiol       Date:  2000-10       Impact factor: 5.948

Review 2.  Statistical methods in microbiology.

Authors:  D M Ilstrup
Journal:  Clin Microbiol Rev       Date:  1990-07       Impact factor: 26.132

3.  The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations.

Authors:  M P Weinstein; L B Reller; J R Murphy; K A Lichtenstein
Journal:  Rev Infect Dis       Date:  1983 Jan-Feb
  3 in total
  4 in total

1.  Validation of performance of plastic versus glass bottles for culturing anaerobes from blood in BacT/ALERT SN medium.

Authors:  Stanley Mirrett; Maria J Joyce; L Barth Reller
Journal:  J Clin Microbiol       Date:  2005-12       Impact factor: 5.948

2.  Relevance of routine use of the anaerobic blood culture bottle.

Authors:  Patrick Grohs; Jean-Luc Mainardi; Isabelle Podglajen; Xavier Hanras; C Eckert; A Buu-Hoï; E Varon; Laurent Gutmann
Journal:  J Clin Microbiol       Date:  2007-06-20       Impact factor: 5.948

3.  Controlled clinical comparison of plastic versus glass bottles of BacT/ALERT PF medium for culturing blood from children.

Authors:  Cathy A Petti; Stanley Mirrett; Christopher W Woods; L Barth Reller
Journal:  J Clin Microbiol       Date:  2005-01       Impact factor: 5.948

4.  Evaluation of acridine orange staining as a replacement of subcultures for BacT/ALERT-positive, gram stain-negative blood cultures.

Authors:  Hildegard Adler; Nathalie Baumlin; Reno Frei
Journal:  J Clin Microbiol       Date:  2003-11       Impact factor: 5.948

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.