Literature DB >> 11060360

Coronal acetabular fractures: the anterior approach in computed tomography-navigated minimally invasive percutaneous fixation.

A L Jacob1, N Suhm, A Kaim, P Regazzoni, W Steinbrich, P Messmer.   

Abstract

PURPOSE: To demonstrate the technical feasibility of the anterior approach to the coronal roof component of carefully selected acetabular fractures in computed tomography (CT)-navigated closed reduction and percutaneous fixation (CRPF).
METHODS: Four patients with nondisplaced or slightly displaced coronal fractures of the acetabular roof were treated with percutaneous screw fixation. Screws were implanted over guidepins placed under CT navigation. Mean clinical and radiological follow-up was 16 months.
RESULTS: All screws could be placed as intended. There were no peri- or postoperative complications. Radiological follow-up showed primary osseous union. Clinical results were excellent according to a median Merle-d'Aubigné score of 18.
CONCLUSION: Nondisplaced or slightly displaced coronally oriented fractures of the acetabular roof can be treated by minimally invasive percutaneous CT-navigated fixation through an anterior approach that does not endanger the sciatic nerve. Early clinical results are encouraging. Close cooperation between trauma surgeons and radiologists and careful selection of cases is mandatory.

Entities:  

Mesh:

Year:  2000        PMID: 11060360     DOI: 10.1007/s002700010061

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  5 in total

1.  [Computer-assisted surgery for pelvic injuries].

Authors:  T Hüfner; J Geerling; A Gänsslen; D Kendoff; C Citak; P Grützner; C Krettek
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

Review 2.  [Fractures of the acetabulum. Diagnostic and therapeutic strategies].

Authors:  B Schmidt-Rohlfing; H Reilmann; H-C Pape
Journal:  Unfallchirurg       Date:  2010-03       Impact factor: 1.000

3.  [Percutaneously navigated balloon fracture reduction in a displaced acetabular fracture].

Authors:  B König; C Khodadadyan; A Schäffler; R Pflugmacher; U Stöckle
Journal:  Unfallchirurg       Date:  2007-12       Impact factor: 1.000

4.  [Percutaneous reduction and stabilization of a dislocated acetabular fracture. Case report].

Authors:  B König; K Schaser; A Schäffler; U Stöckle; N Haas
Journal:  Unfallchirurg       Date:  2006-04       Impact factor: 1.000

5.  Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for Percutaneous Retrograde Screwing for Anterior Column Fracture of Acetabulum: An Observational Study.

Authors:  Jiliang He; Guoqing Tan; Dongsheng Zhou; Liang Sun; Qinghu Li; Yongliang Yang; Ping Liu
Journal:  Medicine (Baltimore)       Date:  2016-01       Impact factor: 1.817

  5 in total