Literature DB >> 17568275

Myocardial first pass perfusion imaging with gadobutrol: impact of parallel imaging algorithms on image quality and signal behavior.

Daniel Theisen1, Bernd J Wintersperger, Armin Huber, Olaf Dietrich, Maximilian F Reiser, Stefan O Schönberg.   

Abstract

OBJECTIVE: To implement parallel imaging algorithms in fast gradient recalled echo sequences for myocardial perfusion imaging and evaluate image quality, signal-to-noise ratio (SNR), contrast-enhancement ratio (CER), and semiquantitative perfusion parameters.
MATERIALS AND METHODS: In 20 volunteers, myocardial perfusion imaging with gadobutrol was performed at rest using an accelerated TurboFLASH sequence (TR 2.3 milliseconds, TE 0.93 milliseconds, flip angle [FA] 15 degrees) with GRAPPA, R=2. A nonaccelerated TurboFLASH sequence with similar scan parameters served as standard of reference. Artifacts were assessed qualitatively. SNR, CER, and CNR were calculated and semiquantitative perfusion parameters were determined from fitted SI-time curves.
RESULTS: Phantom measurements yielded significant higher SNR for nonaccelerated images (P<0.001). CER was equal; differences in CNR were statistically nonsignificant. The evaluation of semiquantitative perfusion parameters yielded significantly higher peak signal intensities in nonaccelerated images (P<0.001). Differences in maximum upslope were statistically nonsignificant. A qualitative examination of all images for artifacts by 2 board-certified radiologists yielded a significant reduction in dark rim artifacts with GRAPPA, R=2 (P<0.001).
CONCLUSIONS: The application of GRAPPA with an acceleration factor of R=2 leads to a significant reduction of dark rim artifacts in fast gradient recalled echo sequences.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17568275     DOI: 10.1097/RLI.0b013e3180383572

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

1.  [Cardiac magnetic resonance imaging: from imaging to diagnosis].

Authors:  M Gutberlet
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

2.  Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient HYPR methods in canine with stenotic coronary arteries.

Authors:  Lan Ge; Aya Kino; Daniel Lee; Rohan Dharmakumar; James C Carr; Debiao Li
Journal:  J Comput Assist Tomogr       Date:  2010 Sep-Oct       Impact factor: 1.826

3.  Myocardial perfusion MRI with an undersampled 3D stack-of-stars sequence.

Authors:  Liyong Chen; Ganesh Adluru; Matthias C Schabel; Chris J McGann; Edward V R Dibella
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

4.  MRI and CT in the diagnosis of coronary artery disease: indications and applications.

Authors:  Konstantin Nikolaou; Hatem Alkadhi; Fabian Bamberg; Sebastian Leschka; Bernd J Wintersperger
Journal:  Insights Imaging       Date:  2010-11-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.