Literature DB >> 17565020

Can mediastinal nodal mobility explain the low yield rates for transbronchial needle aspiration without real-time imaging?

Anna H M Piet1, Frank J Lagerwaard, Peter W A Kunst, John R van Sörnsen de Koste, Ben J Slotman, Suresh Senan.   

Abstract

BACKGROUND: The diagnostic yields with transbronchial needle aspiration (TBNA) for mediastinal nodes are highly variable. Nodal positions, as assessed on a breath-hold conventional CT scan, do not account for nodal motion. We studied nodal motion on four-dimensional (4D) CT scans.
METHODS: A total of 47 mediastinal nodes were identified on 4D CT scans performed for radiotherapy planning in 25 patients with lung cancer. Nodes were mainly located at stations 4R, 4L, 7, and 2R, and each identified node was contoured in all 10 phases of the 4D CT scan. Nodal motion was correlated with changes in carina position.
RESULTS: The mean (+/- SD) nodal diameter was 10.2 +/- 4.0 mm; and the mean nodal volume was 1.8 +/- 2.3 mL. Movement was maximal in the craniocaudal axis (mean length, 4.7 +/- 2.3 mm), and the corresponding mean mediolateral and ventrodorsal movements were 2.8 +/- 1.9 mm and 2.4 +/- 1.8 mm, respectively. The mean three-dimensional displacement of the nodal center was 6.2 +/- 2.9 mm, and it exceeded 10 mm in five nodes. The nodal mass was constantly present in only 25 +/- 14% of the region encompassing all nodal positions. The mean variation in craniocaudal distance between all nodes and the carina position during respiration was 5.3 +/- 2.1 mm (range, 2.2 to 10.5 mm).
CONCLUSIONS: Both nodal motion and the varying distance between the carina and nodal position may explain the lower diagnostic yields for TBNA procedures performed without real-time guidance.

Entities:  

Mesh:

Year:  2007        PMID: 17565020     DOI: 10.1378/chest.06-2964

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  7 in total

1.  A strategy to improve the yield of transbronchial needle aspiration.

Authors:  Ghee Chee Phua; Kyung-Jae Rhee; Mariko Koh; Chian Min Loo; Pyng Lee
Journal:  Surg Endosc       Date:  2010-02-21       Impact factor: 4.584

2.  Conventional transbronchial needle aspiration with 23 gauge needle: a preliminary study.

Authors:  Maria Majori; Miriam Anghinolfi; Alessandro Scarascia; Rita Nizzoli; Angelo Gianni Casalini
Journal:  J Thorac Dis       Date:  2015-04       Impact factor: 2.895

3.  Utility of EBUS-TBNA for diagnosis of mediastinal tuberculous lymphadenitis: a multicentre Australian experience.

Authors:  James Geake; Gary Hammerschlag; Phan Nguyen; Peter Wallbridge; Grant A Jenkin; Tony M Korman; Barton Jennings; Douglas F Johnson; Louis B Irving; Michael Farmer; Daniel P Steinfort
Journal:  J Thorac Dis       Date:  2015-03       Impact factor: 2.895

4.  Tumor, lymph node, and lymph node-to-tumor displacements over a radiotherapy series: analysis of interfraction and intrafraction variations using active breathing control (ABC) in lung cancer.

Authors:  Elisabeth Weiss; Scott P Robertson; Nitai Mukhopadhyay; Geoffrey D Hugo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-12-22       Impact factor: 7.038

5.  Inferring positions of tumor and nodes in Stage III lung cancer from multiple anatomical surrogates using four-dimensional computed tomography.

Authors:  Kathleen T Malinowski; Jason R Pantarotto; Suresh Senan; Thomas J McAvoy; Warren D D'Souza
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-03       Impact factor: 7.038

Review 6.  Clinical and surgical-pathological staging in early non-small cell lung cancer.

Authors:  Ioannis Koukis; Ioannis Gkiozos; Ioannis Ntanos; Elias Kainis; Konstantinos N Syrigos
Journal:  Oncol Rev       Date:  2013-12-02

7.  Respiratory motion variability of primary tumors and lymph nodes during radiotherapy of locally advanced non-small-cell lung cancers.

Authors:  Nuzhat Jan; Geoffrey D Hugo; Nitai Mukhopadhyay; Elisabeth Weiss
Journal:  Radiat Oncol       Date:  2015-06-14       Impact factor: 3.481

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.