Literature DB >> 25973244

Conventional transbronchial needle aspiration with 23 gauge needle: a preliminary study.

Maria Majori1, Miriam Anghinolfi1, Alessandro Scarascia1, Rita Nizzoli1, Angelo Gianni Casalini1.   

Abstract

BACKGROUND: Conventional transbronchial needle aspiration (cTBNA) is a safe and minimally invasive procedure with a high yield for the diagnosis of large lymph nodes (LNs) in favourable locations (LNs >1.5 cm in stations #4R and/or #7). However, it is usually underutilized by pulmonologist. One of the main reasons given for not performing cTBNA is the risk of puncturing vascular structures of the mediastinum. Recently, with the twofold objective of minimize the risk of bleeding and reduce the cTBNA cost, a thinner and less expensive needle has been commercialized. It is a 23 gauge (G) needle that costs 34, 37 €. The aim of our study was to analyze the sample adequacy, diagnostic accuracy and safety of this needle in comparison with 21 and 22 G needles (average cost: 6,400 €).
METHODS: We retrospectively analysed medical records from patients who underwent bronchoscopy with cTBNA for the diagnosis of LNs >1.5 cm in stations #4R and/or #7 at the Thoracic Endoscopy Unit of the University Hospital of Parma from January 1st, 2007 to October 31(st), 2011. Five hundred patients underwent cTBNA from January 1(st), 2007 to October 31(st), 2011. In order to reduce the technical and personal bias for sampling procedure we analyzed only cases sampled by a single well-trained bronchoscopist, particularly skilful at cTBNA.
RESULTS: A total of 222 patients (186 men; mean age 63 years±12, range 6-89) with LNs >1.5 cm in stations #4R and/or #7 were identified. A 23 G needle was used in 84 patients (38%), a 21 G needle in 88 patients (40%) and a 22 G needle in 50 patients (22%). No statistically significant differences between the 23 G group and the 21 or 22 G group in sample adequacy (P=0.78 and P=0.12, respectively) and diagnostic accuracy (P=0.9 and P=0.4, respectively) were found. There were no intraprocedural or postprocedural complications irrespective of the size of needle used.
CONCLUSIONS: Transbronchial 23 G needle is as safe and effective as the 21 and 22 G needle for the sampling of LNs >1.5 cm in stations #4R and/or #7. For this reason, to obtain cytology specimens from large LNs in favourable locations, the 23 G needle may represent an alternative and less expensive choice compared to 21 and 22 G needles, even if our observation needs to be confirmed in a larger prospective study.

Entities:  

Keywords:  23 gauge (G); Conventional transbronchial needle aspiration (cTBNA)

Year:  2015        PMID: 25973244      PMCID: PMC4419292          DOI: 10.3978/j.issn.2072-1439.2015.04.26

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  17 in total

1.  Mediastinal hematoma following transbronchial needle aspiration.

Authors:  Luigi Lazzari Agli; Rocco Trisolini; Marcellino Burzi; Marco Patelli
Journal:  Chest       Date:  2002-09       Impact factor: 9.410

2.  Comparison of 21-gauge and 22-gauge aspiration needle during endobronchial ultrasound-guided transbronchial needle aspiration.

Authors:  Takahiro Nakajima; Kazuhiro Yasufuku; Ryo Takahashi; Masato Shingyoji; Tetsushi Hirata; Makiko Itami; Yukiko Matsui; Meiji Itakura; Toshihiko Iizasa; Hideki Kimura
Journal:  Respirology       Date:  2011-01       Impact factor: 6.424

3.  While waiting to buy a ferrari, do not leave your current car in the garage!

Authors:  Rocco Trisolini; Marco Patelli; Stefano Gasparini
Journal:  Respiration       Date:  2010-02-17       Impact factor: 3.580

Review 4.  Transbronchial needle aspiration: a systematic review on predictors of a successful aspirate.

Authors:  Martina Bonifazi; Lina Zuccatosta; Rocco Trisolini; Lorenzo Moja; Stefano Gasparini
Journal:  Respiration       Date:  2013-06-29       Impact factor: 3.580

5.  Is it time for conventional TBNA to die?

Authors:  Rocco Trisolini; Stefano Gasparini
Journal:  J Bronchology Interv Pulmonol       Date:  2013-10

Review 6.  Accuracy of transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: a meta-analysis.

Authors:  J-E C Holty; W G Kuschner; M K Gould
Journal:  Thorax       Date:  2005-06-30       Impact factor: 9.139

7.  Hemomediastinum after transbronchial needle aspiration.

Authors:  R F Kucera; G K Wolfe; M E Perry
Journal:  Chest       Date:  1986-09       Impact factor: 9.410

8.  Endobronchial ultrasound-guided transbronchial needle aspiration vs conventional transbronchial needle aspiration in the diagnosis of sarcoidosis.

Authors:  Dheeraj Gupta; Devendra S Dadhwal; Ritesh Agarwal; Nalini Gupta; Amanjit Bal; Ashutosh N Aggarwal
Journal:  Chest       Date:  2014-09       Impact factor: 9.410

9.  Survey of flexible fibreoptic bronchoscopy in the United Kingdom.

Authors:  C M Smyth; R J Stead
Journal:  Eur Respir J       Date:  2002-03       Impact factor: 16.671

10.  Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience.

Authors:  T E Yusuf; S Ho; D A Pavey; H Michael; F G Gress
Journal:  Endoscopy       Date:  2009-05-05       Impact factor: 10.093

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.