A new device for measuring resting energy expenditure (REE) in healthy subjects.

Marcella Malavolti1, Angelo Pietrobelli, Manfredo Dugoni, Marco Poli, Elisa Romagnoli, Paolo De Cristofaro, Nino C Battistini.   

Abstract

BACKGROUND AND AIM: Lifestyle change targeted towards increasing daily resting energy expenditure (REE) is one of the cornerstones of obesity treatment. Measurements of energy expenditure and substrate utilization are essential to understanding the metabolic basis of obesity, and the physiological responses to perturbations in habitual food intake. REE is the largest part of human energy expenditure (60-70%) and an increase or decrease in REE would have a large impact on total energy. Accurate and easy-to-use methods for measuring REE are needed, to be applied by clinicians in daily clinical settings to assess the validity of a new instrument to estimate REE in normal weight, healthy adults.
METHODS: Ninety-nine subjects (52 females and 47 males) (mean+/-SD, age 38+/-14 years; body mass index (BMI) 23+/-3 kg/m(2)) were tested. REE was assessed using a Sensor Medics Vmax metabolic cart with a ventilated canopy and with the SenseWear armband. Body composition, percentage fat mass (%FM) and percentage fat free mass (%FFM) were assessed by skinfold thickness measurements (SF), bio-electrical impedance analysis (BIA) and air displacement plethysmography (BOD-POD).
RESULTS: No significant difference was found among measurements of FFM using the three different techniques. Both SenseWear and Sensor Medics Vmax showed a high correlation, r=0.42 and r=0.40 (p<0.0001) respectively, with BMI. No significant difference was found in mean REE between SenseWear (1540+/-280 kcal/day) and Sensor Medics Vmax (1700+/-330 kcal/day) (p=ns) and the correlation between REE measured by SenseWear and Sensor Medics Vmax was high (r=0.86, p<0.0001). Bland-Altman plot showed no difference in REE determination between SenseWear and Sensor Medics Vmax. %FFM determined by BOD-POD correlated with SenseWear (r=0.42, p<0.0001) as well as Sensor Medics Vmax (r=0.38, p<0.001).
CONCLUSION: SF, BIA and BOD-POD provide valid and reliable measurements of FFM. Our results suggest that the SenseWear armband is an acceptable device to accurately measure REE in healthy subjects. Its characteristics have the potential to reduce measurement times and make the SenseWear armband useful for epidemiological studies.

Entities:  

Mesh:

Year:  2006        PMID: 17562571     DOI: 10.1016/j.numecd.2005.12.009

Source DB:  PubMed          Journal:  Nutr Metab Cardiovasc Dis        ISSN: 0939-4753            Impact factor:   4.222


  34 in total

Review 1.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

2.  Validation of the SenseWear Armband at high intensity exercise.

Authors:  Clemens Drenowatz; Joey C Eisenmann
Journal:  Eur J Appl Physiol       Date:  2010-10-24       Impact factor: 3.078

3.  Measuring the effects of heat wave episodes on the human body's thermal balance.

Authors:  George Katavoutas; George Theoharatos; Helena A Flocas; Dimosthenis N Asimakopoulos
Journal:  Int J Biometeorol       Date:  2009-01-10       Impact factor: 3.787

4.  Reduced sleep duration affects body composition, dietary intake and quality of life in obese subjects.

Authors:  Eleonora Poggiogalle; Carla Lubrano; Lucio Gnessi; Chiara Marocco; Luca Di Lazzaro; Giampaolo Polidoro; Federica Luisi; Gianluca Merola; Stefania Mariani; Silvia Migliaccio; Andrea Lenzi; Lorenzo M Donini
Journal:  Eat Weight Disord       Date:  2016-02-25       Impact factor: 4.652

5.  [Intensive care patients. Determining daily energy expenditure - a comparison of two methods].

Authors:  K Rokuss; A Kalenka; H-J Bender; J Hinkelbein
Journal:  Anaesthesist       Date:  2009-08       Impact factor: 1.041

6.  Validation of the Sensewear Armband during recreational in-line skating.

Authors:  Maroje Soric; Pavle Mikulic; Marjeta Misigoj-Durakovic; Lana Ruzic; Goran Markovic
Journal:  Eur J Appl Physiol       Date:  2011-06-17       Impact factor: 3.078

7.  Evaluation of a non-invasive multisensor accelerometer for calculating energy expenditure in ventilated intensive care patients compared to indirect calorimetry and predictive equations.

Authors:  Janine Krüger; Matthias Kraft; Matthias Gründling; Sigrun Friesecke; Simone Gärtner; Lena J Vogt; Nicole Schüler; Antje Steveling; Markus M Lerch; Ali A Aghdassi
Journal:  J Clin Monit Comput       Date:  2016-09-14       Impact factor: 2.502

8.  Increased catabolic state in spinocerebellar ataxia type 1 patients.

Authors:  Anja Mähler; Jochen Steiniger; Matthias Endres; Friedemann Paul; Michael Boschmann; Sarah Doss
Journal:  Cerebellum       Date:  2014-08       Impact factor: 3.847

9.  [Postoperative assessment of daily energy expenditure. Comparison of two methods].

Authors:  R Dummler; A Zittermann; M Schäfer; M Emmerich
Journal:  Anaesthesist       Date:  2013-01-16       Impact factor: 1.041

10.  BounceBack capsules for reduction of DOMS after eccentric exercise: a randomized, double-blind, placebo-controlled, crossover pilot study.

Authors:  Jay K Udani; Betsy B Singh; Vijay J Singh; Elizabeth Sandoval
Journal:  J Int Soc Sports Nutr       Date:  2009-06-05       Impact factor: 5.150

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.