Literature DB >> 17558738

Radiofrequency ablation with a high-power generator: device efficacy in an in vivo porcine liver model.

C L Brace1, P F Laeseke, L A Sampson, T M Frey, R Mukherjee, F T Lee.   

Abstract

PURPOSE: The purpose of this study was to test the feasibility and efficacy of using a high-power generator with nondeployable electrodes to create large zones of coagulation in an in vivo porcine liver model.
METHODS: With approval from our institution's research animal care and use committee, 12 female swine (mean weight = 55 kg) were anesthetized and received RF ablation at laparotomy. Twenty-nine ablations were performed in four groups using: (i) a conventional 200-W generator and cluster electrode (n = 4), or an experimental prototype 250-W generator and (ii) a single, 17-gauge electrode (n = 9), (iii) a cluster electrode (n = 8) or (iv) three electrodes spaced 2.0 cm apart in a triangular configuration (n = 8). In the three-electrode group, power was applied by switching between electrodes using a prototype switching device. All electrodes were internally cooled. Ablation zone size, shape and generator data from each group were compared using a mixed-linear model with animals modeled as random effects.
RESULTS: The high-power generator was able to increase significantly the zone of coagulation. Mean (+/-SD) ablation diameter was largest in the switched group (4.31 +/- 0.7 cm) followed by the cluster (3.98 +/- 0.5 cm) and single-electrode (3.26 +/- 0.5 cm) groups. Mean diameter in the high-power single-electrode group was no different than the low-power cluster group (3.25 +/- 0.4 cm, p = 0.98). Circularity measures were high (>0.75) in all groups.
CONCLUSIONS: Coupling a high-power generator and switching device is feasible. At higher powers, the switching device creates larger zones of ablation than cluster or single electrodes. Single-electrode ablations created with the prototype high-power generator were equivalent to those produced with the cluster electrode at conventional lower powers.

Entities:  

Mesh:

Year:  2007        PMID: 17558738     DOI: 10.1080/02656730701397858

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  13 in total

Review 1.  Principles of and advances in percutaneous ablation.

Authors:  Muneeb Ahmed; Christopher L Brace; Fred T Lee; S Nahum Goldberg
Journal:  Radiology       Date:  2011-02       Impact factor: 11.105

2.  Microwaves create larger ablations than radiofrequency when controlled for power in ex vivo tissue.

Authors:  A Andreano; Yu Huang; M Franca Meloni; Fred T Lee; Christopher Brace
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

3.  A comparative evaluation of ablations produced by high-frequency coagulation-, argon plasma coagulation-, and cryotherapy devices in porcine liver.

Authors:  J Sperling; C Ziemann; J Schuld; M W Laschke; M K Schilling; M D Menger; O Kollmar
Journal:  Int J Colorectal Dis       Date:  2012-05-31       Impact factor: 2.571

4.  MR Coagulation: A Novel Minimally Invasive Approach to Aneurysm Repair.

Authors:  Ouri Cohen; Ming Zhao; Erez Nevo; Jerome L Ackerman
Journal:  J Vasc Interv Radiol       Date:  2017-08-09       Impact factor: 3.464

5.  Magnetic Resonance Mediated Radiofrequency Ablation.

Authors:  Yik-Kiong Hue; Alexander R Guimaraes; Ouri Cohen; Erez Nevo; Abraham Roth; Jerome L Ackerman
Journal:  IEEE Trans Med Imaging       Date:  2017-09-18       Impact factor: 10.048

Review 6.  Thermal tumor ablation in clinical use.

Authors:  C Brace
Journal:  IEEE Pulse       Date:  2011 Sep-Oct       Impact factor: 0.924

7.  Sequential activation of ground pads reduces skin heating during radiofrequency ablation: initial in vivo porcine results.

Authors:  David J Schutt; M Michael Swindle; Gorka A Bastarrika; Dieter Haemmerich
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

8.  Sequential activation of multiple grounding pads reduces skin heating during radiofrequency tumor ablation.

Authors:  Dieter Haemmerich; David James Schutt
Journal:  Int J Hyperthermia       Date:  2007-11       Impact factor: 3.914

9.  Sequential activation of a segmented ground pad reduces skin heating during radiofrequency tumor ablation: optimization via computational models.

Authors:  David J Schutt; Dieter Haemmerich
Journal:  IEEE Trans Biomed Eng       Date:  2008-07       Impact factor: 4.538

10.  Sequential activation of ground pads reduces skin heating during radiofrequency tumor ablation: in vivo porcine results.

Authors:  David J Schutt; M Michael Swindle; Kristi L Helke; Gorka Bastarrika; Florian Schwarz; Dieter Haemmerich
Journal:  IEEE Trans Biomed Eng       Date:  2009-10-09       Impact factor: 4.538

View more