INTRODUCTION: Hepatic resection is the only curative treatment option for primary or metastatic malignancies of the liver. Although R1 resections can also lead to prolonged survival, the main surgical goal is complete tumor resection (R0). To achieve this, additional treatment of the resection margin with ablation devices is discussed. Using a porcine in vivo model, we therefore analyzed the effect of different ablation devices on depth and completeness of hepatic parenchymal cell destruction. METHODS: Swabian-Hall strain pigs underwent ablation on the surface of the right, middle, or left liver lobe using seven different types of high-frequency (HF)-, cryotherapy (Cryo)-, or argon plasma coagulation (APC) devices. Penetration depth and volume were analyzed from histological sections. Severity of parenchymal cell destruction was assessed by a histomorphological score. RESULTS: The greatest penetration depth was achieved with Cryo (10.4 ± 1.7 mm), whereas HF and APC exhibited a smaller penetration depth. However, HF and APC compared to Cryo achieved complete destruction of the intralobular architecture and hepatocellular morphology depending on the application time and the adjusted power. CONCLUSION: HF, APC, and Cryo applied to the liver surface induce different parenchymal penetration depth and cell destruction. HF and APC are considered to be standard surgical instruments and therefore recommended as standard treatment, whereas Cryo may be used only if particularly deep penetration is required.
INTRODUCTION: Hepatic resection is the only curative treatment option for primary or metastatic malignancies of the liver. Although R1 resections can also lead to prolonged survival, the main surgical goal is complete tumor resection (R0). To achieve this, additional treatment of the resection margin with ablation devices is discussed. Using a porcine in vivo model, we therefore analyzed the effect of different ablation devices on depth and completeness of hepatic parenchymal cell destruction. METHODS: Swabian-Hall strain pigs underwent ablation on the surface of the right, middle, or left liver lobe using seven different types of high-frequency (HF)-, cryotherapy (Cryo)-, or argon plasma coagulation (APC) devices. Penetration depth and volume were analyzed from histological sections. Severity of parenchymal cell destruction was assessed by a histomorphological score. RESULTS: The greatest penetration depth was achieved with Cryo (10.4 ± 1.7 mm), whereas HF and APC exhibited a smaller penetration depth. However, HF and APC compared to Cryo achieved complete destruction of the intralobular architecture and hepatocellular morphology depending on the application time and the adjusted power. CONCLUSION: HF, APC, and Cryo applied to the liver surface induce different parenchymal penetration depth and cell destruction. HF and APC are considered to be standard surgical instruments and therefore recommended as standard treatment, whereas Cryo may be used only if particularly deep penetration is required.
Authors: W R Jarnagin; Y Fong; R P DeMatteo; M Gonen; E C Burke; J Bodniewicz BS; M Youssef BA; D Klimstra; L H Blumgart Journal: Ann Surg Date: 2001-10 Impact factor: 12.969
Authors: Abraham R John; Saboor Khan; Darius F Mirza; A David Mayer; John A C Buckels; Simon R Bramhall Journal: Dig Surg Date: 2006-06-06 Impact factor: 2.588
Authors: Hauke Lang; Georgios C Sotiropoulos; Nils R Frühauf; Marco Dömland; Andreas Paul; Eva-Maria Kind; Massimo Malagó; Christoph E Broelsch Journal: Ann Surg Date: 2005-01 Impact factor: 12.969
Authors: Sebastian Senger; Jens Sperling; Barbara Oberkircher; Martin K Schilling; Otto Kollmar; Michael D Menger; Christian Ziemann Journal: Clin Exp Metastasis Date: 2017-06-19 Impact factor: 5.150
Authors: Tim R Glowka; Jens Standop; Pascal Paschenda; Michael Czaplik; Jörg C Kalff; René H Tolba Journal: J Int Med Res Date: 2017-06-29 Impact factor: 1.671
Authors: Bin Jin; Zhengchen Jiang; Sanyuan Hu; Gang Du; Binyao Shi; Du Kong; Jinhuan Yang Journal: Biomed Res Int Date: 2018-01-16 Impact factor: 3.411