Literature DB >> 1754623

Dependence of the velocity and attenuation of ultrasound in bone on the mineral content.

M B Tavakoli1, J A Evans.   

Abstract

Measurements of the attenuation and velocity of ultrasound from 0.3 to 0.8 MHz have been performed on a number of bovine cancellous bone samples. The influence of bone mineral content has been isolated by measuring the acoustic properties of the samples at various stages of demineralization resulting from controlled nitric acid attack. The correlation coefficient r, between the attenuation at different frequencies and bone density was found to be in the range 0.68-0.97. Broadband ultrasonic attenuation (BUA) was also calculated and produced r values between 0.84 and 0.99. The velocity measurements indicated a correlation greater than 0.97 in all cases. Thus velocity is the parameter most sensitive to changes in bone mineral density alone. Attenuation and BUA are less well correlated presumably because of a sensitivity to minor structural change.

Entities:  

Mesh:

Year:  1991        PMID: 1754623     DOI: 10.1088/0031-9155/36/11/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  45 in total

1.  A numerical method to predict the effects of frequency-dependent attenuation and dispersion on speed of sound estimates in cancellous bone.

Authors:  K A Wear
Journal:  J Acoust Soc Am       Date:  2001-03       Impact factor: 1.840

2.  Frequency dependence of ultrasonic backscatter from human trabecular bone: theory and experiment.

Authors:  K A Wear
Journal:  J Acoust Soc Am       Date:  1999-12       Impact factor: 1.840

3.  Anisotropy of ultrasonic backscatter and attenuation from human calcaneus: implications for relative roles of absorption and scattering in determining attenuation.

Authors:  K A Wear
Journal:  J Acoust Soc Am       Date:  2000-06       Impact factor: 1.840

4.  Fundamental precision limitations for measurements of frequency dependence of backscatter: applications in tissue-mimicking phantoms and trabecular bone.

Authors:  K A Wear
Journal:  J Acoust Soc Am       Date:  2001-12       Impact factor: 1.840

5.  Relationships among calcaneal backscatter, attenuation, sound speed, hip bone mineral density, and age in normal adult women.

Authors:  K A Wear; D W Armstrong
Journal:  J Acoust Soc Am       Date:  2001-07       Impact factor: 1.840

6.  The dependence of ultrasonic backscatter on trabecular thickness in human calcaneus: theoretical and experimental results.

Authors:  Keith A Wear; Andres Laib
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-08       Impact factor: 2.725

7.  A comparison of the stiffness, density and composition of bone from the calcar femorale and the femoral cortex.

Authors:  B Li; R M Aspden
Journal:  J Mater Sci Mater Med       Date:  1998-11       Impact factor: 3.896

8.  The dependencies of phase velocity and dispersion on trabecular thickness and spacing in trabecular bone-mimicking phantoms.

Authors:  Keith A Wear
Journal:  J Acoust Soc Am       Date:  2005-08       Impact factor: 1.840

9.  Use of multiple acoustic wave modes for assessment of long bones: model study.

Authors:  Alexey Tatarinov; Noune Sarvazyan; Armen Sarvazyan
Journal:  Ultrasonics       Date:  2005-03-31       Impact factor: 2.890

10.  The dependence of time-domain speed-of-sound measurements on center frequency, bandwidth, and transit-time marker in human calcaneus in vitro.

Authors:  Keith A Wear
Journal:  J Acoust Soc Am       Date:  2007-07       Impact factor: 1.840

View more