Frequency-dependent phase velocity was measured in trabecular-bone-mimicking phantoms consisting of two-dimensional arrays of parallel nylon wires (simulating trabeculae) with thicknesses ranging from 152 to 305 microm and spacings ranging from 700 to 1000 microm. Phase velocity varied approximately linearly with frequency over the range from 400 to 750 kHz. Dispersion was characterized by the slope of a linear least-squares regression fit to phase velocity versus frequency data. The increase in phase velocity (compared with that in water) at 500 kHz was approximately proportional to the (1) square of trabecular thickness, (2) inverse square of trabecular spacing, and (3) volume fraction occupied by nylon wires. The first derivative of phase velocity with respect to frequency was negative and exhibited nonlinear, monotonically decreasing dependencies on trabecular thickness and volume fraction. The dependencies of phase velocity and its first derivative on volume fraction in the phantoms were consistent with those reported in trabecular bone.Entities:
Mesh:
Substances:
Year: 2005 PMID: 16158673 PMCID: PMC8215567 DOI: 10.1121/1.1940448
Source DB: PubMed Journal: J Acoust Soc Am ISSN: 0001-4966 Impact factor: 1.840