Literature DB >> 17540280

Parallel imaging for first-pass myocardial perfusion.

Roy Irwan1, Daniël D Lubbers, Pieter A van der Vleuten, Peter Kappert, Marco J W Götte, Paul E Sijens.   

Abstract

Two parallel imaging methods used for first-pass myocardial perfusion imaging were compared in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image artifacts. One used adaptive Time-adaptive SENSitivity Encoding (TSENSE) and the other used GeneRalized Autocalibrating Partially Parallel Acquisition (GRAPPA), which are both applied to a gradient-echo sequence. Both methods were tested on 12 patients with coronary artery disease. The order of perfusion sequences was inverted in every other patient. Image acquisition was started during the administration of a contrast bolus followed by a 20-ml saline flush (3 ml/s), and the next perfusion was started at least 15 min thereafter using an identical bolus. An acceleration rate of 2 was used in both methods, and acquisition was performed during breath-holding. Significantly higher SNR, CNR and image quality were obtained with GRAPPA images than with TSENSE images. GRAPPA, however, did not yield a higher CNR when applied after the second bolus. GRAPPA perfusion imaging produced larger differences between subjects than did TSENSE. Compared to TSENSE, GRAPPA produced significantly better CNR on the first bolus. More consistent SNR and CNR were obtained from TSENSE images than from GRAPPA images, indicating that the diagnostic value of TSENSE may be better.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17540280     DOI: 10.1016/j.mri.2006.10.012

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  Multiple-mouse MRI with multiple arrays of receive coils.

Authors:  Marc S Ramirez; Emilio Esparza-Coss; James A Bankson
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

2.  Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient HYPR methods in canine with stenotic coronary arteries.

Authors:  Lan Ge; Aya Kino; Daniel Lee; Rohan Dharmakumar; James C Carr; Debiao Li
Journal:  J Comput Assist Tomogr       Date:  2010 Sep-Oct       Impact factor: 1.826

3.  Myocardial perfusion MRI with an undersampled 3D stack-of-stars sequence.

Authors:  Liyong Chen; Ganesh Adluru; Matthias C Schabel; Chris J McGann; Edward V R Dibella
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

Review 4.  Parallel MR imaging.

Authors:  Anagha Deshmane; Vikas Gulani; Mark A Griswold; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2012-07       Impact factor: 4.813

  4 in total