Literature DB >> 17534910

Joint image reconstruction and sensitivity estimation in SENSE (JSENSE).

Leslie Ying1, Jinhua Sheng.   

Abstract

Parallel magnetic resonance imaging (pMRI) using multichannel receiver coils has emerged as an effective tool to reduce imaging time in various applications. However, the issue of accurate estimation of coil sensitivities has not been fully addressed, which limits the level of speed enhancement achievable with the technology. The self-calibrating (SC) technique for sensitivity extraction has been well accepted, especially for dynamic imaging, and complements the common calibration technique that uses a separate scan. However, the existing method to extract the sensitivity information from the SC data is not accurate enough when the number of data is small, and thus erroneous sensitivities affect the reconstruction quality when they are directly applied to the reconstruction equation. This paper considers this problem of error propagation in the sequential procedure of sensitivity estimation followed by image reconstruction in existing methods, such as sensitivity encoding (SENSE) and simultaneous acquisition of spatial harmonics (SMASH), and reformulates the image reconstruction problem as a joint estimation of the coil sensitivities and the desired image, which is solved by an iterative optimization algorithm. The proposed method was tested on various data sets. The results from a set of in vivo data are shown to demonstrate the effectiveness of the proposed method, especially when a rather large net acceleration factor is used.

Mesh:

Year:  2007        PMID: 17534910     DOI: 10.1002/mrm.21245

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  48 in total

1.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

2.  Trajectory Auto-Corrected image reconstruction.

Authors:  Julianna D Ianni; William A Grissom
Journal:  Magn Reson Med       Date:  2015-09-12       Impact factor: 4.668

3.  Rapid multi-orientation quantitative susceptibility mapping.

Authors:  Berkin Bilgic; Luke Xie; Russell Dibb; Christian Langkammer; Aysegul Mutluay; Huihui Ye; Jonathan R Polimeni; Jean Augustinack; Chunlei Liu; Lawrence L Wald; Kawin Setsompop
Journal:  Neuroimage       Date:  2015-08-12       Impact factor: 6.556

4.  Improved self-calibrated spiral parallel imaging using JSENSE.

Authors:  Jinhua Sheng; Erik Wiener; Bo Liu; Fernando Boada; Leslie Ying
Journal:  Med Eng Phys       Date:  2008-11-21       Impact factor: 2.242

5.  Using GRAPPA to improve autocalibrated coil sensitivity estimation for the SENSE family of parallel imaging reconstruction algorithms.

Authors:  W Scott Hoge; Dana H Brooks
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

6.  Hybrid-Space SENSE Reconstruction for Simultaneous Multi-Slice MRI.

Authors:  Kangrong Zhu; Robert F Dougherty; Hua Wu; Matthew J Middione; Atsushi M Takahashi; Tao Zhang; John M Pauly; Adam B Kerr
Journal:  IEEE Trans Med Imaging       Date:  2016-02-18       Impact factor: 10.048

7.  A majorize-minimize framework for Rician and non-central chi MR images.

Authors:  Divya Varadarajan; Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2015-04-28       Impact factor: 10.048

8.  RARE/turbo spin echo imaging with Simultaneous Multislice Wave-CAIPI.

Authors:  Borjan A Gagoski; Berkin Bilgic; Cornelius Eichner; Himanshu Bhat; P Ellen Grant; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2015-02-02       Impact factor: 4.668

9.  Evaluating quantitative proton-density-mapping methods.

Authors:  Aviv Mezer; Ariel Rokem; Shai Berman; Trevor Hastie; Brian A Wandell
Journal:  Hum Brain Mapp       Date:  2016-06-06       Impact factor: 5.038

10.  STEP: Self-supporting tailored k-space estimation for parallel imaging reconstruction.

Authors:  Zechen Zhou; Jinnan Wang; Niranjan Balu; Rui Li; Chun Yuan
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.