Advantages and limitations of two software calipers in quantitative coronary arteriography.

G Koning1, J H Reiber, C D von Land, G Loois, B van Meurs.   

Abstract

Software calipers allowing the measurement of the distances between pairs of manually defined picture elements in digitized images may be useful tools for a rapid assessment of the morphology of coronary vessels, e.g. for choosing the appropriate balloon or stent sizes before or during cardiac intervention procedures. In this paper we have studied extensively the advantages and limitations of two manual software calipers--one developed for a PC-based cinefilm analysis workstation, the other for the Philips DCI system. Based on analyses of a perspex vessel phantom with 17 sectors of known size filled with different concentrations (50 and 100%) of the contrast agent and acquired at two kV-levels (68 and 92 kV), it was found that the cinefilm approach is characterized by a very small overall (averaged over te data from three observers) systematic overestimation of 0.03 mm, and the DCI system by a systematic underestimation of 0.07 mm; the worst case accuracy value for an individual observer on frames with 100% contrast dye concentration was 0.20 mm for cinefilm, and -0.34 mm for the DCI, respectively. The overall variabilities in the measurements (precision) were almost identical for the two approaches (overall 0.07 and 0.08 mm for the cinefilm and digital approaches, respectively, and worst case for individual observers on the 100% contrast frames, 0.16 and 0.13 mm, respectively. Inverting the images (bright or dark contrast containing structures) of the phantom at 100% contrast concentration and acquired at 62 kV had no significant effect on the results obtained with the cinefilm analysis system (overall accurary -0.12 mm for both situations), whereas it had on the results from the DCI system (overall accuracies -0.29 (dark vessels on bright background) and -0.08 mm (bright vessels on dark background), respectively). Enhancing the digital images on the DCI with unsharp masking techniques did not significantly influence the measurement accuracy and precision. Finally, it was found that woven dacron, polyurethane and polyvinylchloride catheters filled with 100% contrast dye can be measured with an overall accuracy of better than 0.13 mm on the DCI system. On the PC-based system the woven dacron and polyvinylchloride catheters would result in an overall accuracy better than 0.17 mm, and the polyurethane catheter better than 0.30 mm. The evaluation study has made clear that the nylon catheter should not be applied in QCA-studies.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 1753156     DOI: 10.1007/bf01797677

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  9 in total

1.  Case against routine use of glyceryl trinitrate before coronary angiography.

Authors:  R L Feldman; C J Peine; R C Curry; C R Conti
Journal:  Br Heart J       Date:  1978-09

2.  Effects of video frame averaging, smoothing and edge enhancement on the accuracy and precision of quantitative coronary arteriography.

Authors:  K M Kavanaugh; I M Pinto; M J McGillem; S F DeBoe; G B Mancini
Journal:  Int J Card Imaging       Date:  1990

3.  [Width of the large coronary arteries in myocardial hypertrophy using selective arteriography].

Authors:  G Kober; G Spahn; P Spitz; H J Becker; M Kaltenbach
Journal:  Verh Dtsch Ges Kreislaufforsch       Date:  1972

4.  Human coronary artery size during life. A cinearteriographic study.

Authors:  R N MacAlpin; A S Abbasi; J H Grollman; L Eber
Journal:  Radiology       Date:  1973-09       Impact factor: 11.105

5.  Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.

Authors:  J H Reiber; P W Serruys; C J Kooijman; W Wijns; C J Slager; J J Gerbrands; J C Schuurbiers; A den Boer; P G Hugenholtz
Journal:  Circulation       Date:  1985-02       Impact factor: 29.690

6.  Change in diameter of coronary artery segments adjacent to stenosis after percutaneous transluminal coronary angioplasty: failure of percent diameter stenosis measurement to reflect morphologic changes induced by balloon dilation.

Authors:  K J Beatt; H E Luijten; P J de Feyter; M van den Brand; J H Reiber; P W Serruys
Journal:  J Am Coll Cardiol       Date:  1988-08       Impact factor: 24.094

7.  Quantitative angiography: the measurement of coronary vasomobility in the intact animal and man.

Authors:  G G Gensini; A E Kelly; B C Da Costa; P P Huntington
Journal:  Chest       Date:  1971-12       Impact factor: 9.410

8.  A new digital electronic caliper for measurement of coronary arterial stenosis: comparison with visual estimates and computer-assisted measurements.

Authors:  D P Scoblionko; B G Brown; S Mitten; J H Caldwell; J W Kennedy; E L Bolson; H T Dodge
Journal:  Am J Cardiol       Date:  1984-03-01       Impact factor: 2.778

9.  Assessment of dimensions and image quality of coronary contrast catheters from cineangiograms.

Authors:  J H Reiber; C J Kooijman; A den Boer; P W Serruys
Journal:  Cathet Cardiovasc Diagn       Date:  1985
  9 in total
  1 in total

1.  Exercise echocardiography and single photon emission computed tomography in patients with left anterior descending coronary artery stenosis.

Authors:  A Salustri; M M Pozzoli; B Ilmer; W Hermans; A E Reijs; J H Reiber; J R Roelandt; P M Fioretti
Journal:  Int J Card Imaging       Date:  1992
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.