Literature DB >> 1752996

Periodontal aspects of osseointegrated fixtures supporting an overdenture. A 4-year retrospective study.

M Quirynen1, I Naert, D van Steenberghe, J Teerlinck, C Dekeyser, G Theuniers.   

Abstract

196 Brånemark implants in 86 consecutive patients rehabilitated by means of overdentures (6 upper jaws, 80 lower jaws) were observed longitudinally. In each jaw, only 2 implants were used to anchor the overdenture. 2 implants in the lower jaw showed some mobility at the abutment installation and were removed immediately. During the loading period (mean loading time 19.1 months ranging from 4 to 48 months), none of the implants showed any signs of non-integration. The marginal tissue reaction and plaque accumulation were monitored using conventional indices. Clinical methods and standardized radiographs were used to evaluate the bone level and density. The numbers of approximal surfaces without plaque (40%) or with gingival inflammation (55%) were almost constant throughout the study. The probing pocket depths remained within the range of 2.7 to 3.2 mm during the observation time, whereas the distance of the gingival margin from the top of the abutment clearly increased (from 1.8 to 2.9 mm). For loaded lower jaw implants connected to each other with a straight bar, a radiographic bone loss of 0.8 mm was observed during the first postsurgical year followed by a mean annual bone loss of less than 0.1 mm. For the "sleeping" fixtures, 50% less bone loss was recorded. For loaded but not interconnected implants in the upper jaw, the bone loss during the first 6 months reached 2.0 mm. The loss in marginal bone height did not clearly correlate with parameters such as the plaque index, the gingivitis index, the presence or absence of gingiva around the abutment, or the implant length. The present data, with an observation time up to 4 years, showed that the failure rate for Brånemark implants supporting overdentures in the lower jaw can be limited to 1%. However, the use of 2 unconnected fixtures in the upper jaw cannot presently be advocated since considerable bone loss was observed.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1752996     DOI: 10.1111/j.1600-051x.1991.tb00063.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  9 in total

1.  Osseotite implants inserted into fresh frozen bone grafts.

Authors:  Maurizio Franco; Alessandro Viscione; Leone Rigo; Riccardo Guidi; Giorgio Brunelli; Anna Avantaggiato; Francesco Carinci
Journal:  J Maxillofac Oral Surg       Date:  2009-11-21

2.  Clinical outcome of narrow diameter implants inserted into allografts.

Authors:  Maurizio Franco; Alessandro Viscioni; Leone Rigo; Riccardo Guidi; Ilaria Zollino; Anna Avantaggiato; Francesco Carinci
Journal:  J Appl Oral Sci       Date:  2009 Jul-Aug       Impact factor: 2.698

3.  Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment.

Authors:  Yong-Ho Seo; Eun-Bin Bae; Jung-Woo Kim; So-Hyoun Lee; Mi-Jung Yun; Chang-Mo Jeong; Young-Chan Jeon; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

Review 4.  To what extent residual alveolar ridge can be preserved by implant? A systematic review.

Authors:  Ahmed Khalifa Khalifa; Masahiro Wada; Kazunori Ikebe; Yoshinobu Maeda
Journal:  Int J Implant Dent       Date:  2016-11-23

5.  Clinical Evaluation of Complications in Implant-Supported Dentures: A 4-Year Retrospective Study.

Authors:  Sabiha Zelal Ülkü; Filiz Acun Kaya; Ersin Uysal; Belgin Gulsun
Journal:  Med Sci Monit       Date:  2017-12-27

6.  A Clinical Retrospective Study of Distal Extension Removable Partial Denture with Implant Surveyed Bridge or Stud Type Attachment.

Authors:  Eun-Bin Bae; Seong-Jong Kim; Jae-Won Choi; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; So-Hyoun Lee; Jung-Bo Huh
Journal:  Biomed Res Int       Date:  2017-04-09       Impact factor: 3.411

7.  Dental implants inserted in native bone: Cases series analyses.

Authors:  Riccardo Guidi; Alessandro Viscioni; Frencesco Dattola; Francesco Carinci
Journal:  Dent Res J (Isfahan)       Date:  2012-12

8.  A retrospective study on a series of 556 zimmer dental implants.

Authors:  Carlo Maria Soardi; Ezio Zandanel; Elena Rebuffini; Rebuffini Carinci
Journal:  Dent Res J (Isfahan)       Date:  2012-12

9.  Retrospective Clinical Study of a Freely Removable Implant-Supported Fixed Dental Prosthesis by a Microlocking System.

Authors:  Eun-Bin Bae; Won-Tak Cho; Hyun-Young Bae; So-Hyoun Lee; Tae-Hyung Kim; Jung-Bo Huh
Journal:  Biomed Res Int       Date:  2020-11-03       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.