Literature DB >> 17525216

Evaluating retinal function in age-related maculopathy with the ERG photostress test.

Alison M Binns1, Tom H Margrain.   

Abstract

PURPOSE: To evaluate the diagnostic potential of the electroretinogram (ERG) photostress test and the focal cone ERG in age-related maculopathy (ARM).
METHODS: The cohort comprised 31 patients with ARM and 27 age-matched control subjects. The ERG photostress test was used to monitor cone adaptation after intense light adaptation. Focal 41- and 5-Hz cone ERGs were recorded monocularly (central 20 degrees) to assess steady state retinal function. Univariate analysis identified electrophysiological parameters that differed between groups, and receiver operating characteristic (ROC) curves were constructed to assess their diagnostic potential. Logistic regression analysis determined the diagnostic potential of a model incorporating several independent predictors of ARM.
RESULTS: The rate of recovery of the ERG photostress test was reduced (recovery was slower) in subjects with ARM. The parameter exhibited good diagnostic potential (P = 0.002, area under ROC curve = 0.74). The implicit times of the 5-Hz (a-wave, P = 0.002; b-wave, P < 0.001) and the 41-Hz (P < 0.001) focal cone ERGs were increased, and the 41-Hz focal cone ERG amplitude (P = 0.003) and focal to full-field amplitude ratio (P = 0.001) were reduced in the ARM group. Logistic regression analysis identified three independent predictors of ARM, including the rate of recovery of the ERG photostress test.
CONCLUSIONS: Early ARM has a marked effect on the kinetics of cone adaptation. The clinical application of the ERG photostress test increases the sensitivity and specificity of a model for the diagnosis of ARM. Improved assessment of the functional integrity of the central retina will facilitate early diagnosis and evaluation of therapeutic interventions.

Entities:  

Mesh:

Year:  2007        PMID: 17525216     DOI: 10.1167/iovs.06-0392

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  13 in total

Review 1.  Aging and vision.

Authors:  Cynthia Owsley
Journal:  Vision Res       Date:  2010-10-23       Impact factor: 1.886

Review 2.  The electroretinogram: a useful tool for evaluating age-related macular disease?

Authors:  Emma J Berrow; Hannah E Bartlett; Frank Eperjesi; Jonathan M Gibson
Journal:  Doc Ophthalmol       Date:  2010-03-16       Impact factor: 2.379

3.  The effect of bleach duration and age on the ERG photostress test.

Authors:  Ashley Wood; Tom Margrain; Alison Binns
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-02-02       Impact factor: 3.117

4.  Measurement of cone dark adaptation: a comparison of four psychophysical methods.

Authors:  Allannah J Gaffney; Alison M Binns; Tom H Margrain
Journal:  Doc Ophthalmol       Date:  2013-11-22       Impact factor: 2.379

Review 5.  Techniques for extraction of depth-resolved in vivo human retinal intrinsic optical signals with optical coherence tomography.

Authors:  Alexandre R Tumlinson; Boris Hermann; Bernd Hofer; Boris Povazay; Tom H Margrain; Alison M Binns; Wolfgang Drexler
Journal:  Jpn J Ophthalmol       Date:  2009-09-08       Impact factor: 2.447

6.  The repeatability of the Goldmann-Weekers adaptometer for measuring cone adaptation.

Authors:  Allannah J Gaffney; Alison M Binns; Tom H Margrain
Journal:  Doc Ophthalmol       Date:  2011-01-29       Impact factor: 2.379

7.  The value of multifocal electroretinography to predict progressive visual acuity loss in early AMD.

Authors:  L Ambrosio; G Ambrosio; G Nicoletti; G de Crecchio; B Falsini
Journal:  Doc Ophthalmol       Date:  2015-07-02       Impact factor: 2.379

8.  The influence of age on the recovery of the ERG photostress test.

Authors:  D Messenio; G Marano; S Gerosa; F Iannelli; E M Biganzoli
Journal:  Doc Ophthalmol       Date:  2012-11-25       Impact factor: 2.379

9.  Detection of early age-related macular degeneration using novel functional parameters of the focal cone electroretinogram.

Authors:  Ashley Wood; Thomas Margrain; Alison Mary Binns
Journal:  PLoS One       Date:  2014-05-05       Impact factor: 3.240

10.  A short-duration dark adaptation protocol for assessment of age-related maculopathy.

Authors:  Gregory R Jackson; John G Edwards
Journal:  J Ocul Biol Dis Infor       Date:  2008-05-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.