Literature DB >> 17525205

Nondestructive quantification of analyte diffusion in cornea and sclera using optical coherence tomography.

Mohamad G Ghosn1, Valery V Tuchin, Kirill V Larin.   

Abstract

PURPOSE: Noninvasive functional imaging, monitoring, and quantification of analytes transport in epithelial ocular tissues are extremely important for therapy and diagnostics of many eye diseases. In this study the authors investigated the capability of optical coherence tomography (OCT) for noninvasive monitoring and quantification of diffusion of different analytes in sclera and cornea of rabbit eyes.
METHODS: A portable time-domain OCT system with wavelength of 1310 +/- 15 nm, output power of 3.5 mW, and resolution of 25 mum was used in this study. Diffusion of different analytes was monitored and quantified in rabbit cornea and sclera of whole eyeballs. Diffusion of water, metronidazole (0.5%), dexamethasone (0.2%), ciprofloxacin (0.3%), mannitol (20%), and glucose solution (20%) were examined, and their permeability coefficients were calculated by using OCT signal slope and depth-resolved amplitude methods.
RESULTS: Permeability coefficients were calculated as a function of time and tissue depth. For instance, mannitol was found to have a permeability coefficient of (8.99 +/- 1.43) x 10(-6) cm/s in cornea and (6.18 +/- 1.08) x 10(-6) cm/s in sclera. The permeability coefficient of drugs with small concentrations (where water was the major solvent) was found to be in the range of that of water in the same tissue type, whereas permeability coefficients of higher concentrated solutions varied significantly.
CONCLUSIONS: Results suggest that the OCT technique might be a powerful tool for noninvasive diffusion studies of different analytes in ocular tissues. However, additional methods of OCT signal acquisition and processing are required to study the diffusion of agents of small concentrations.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17525205     DOI: 10.1167/iovs.06-1331

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  13 in total

1.  Depth profiling of photothermal compound concentrations using phase sensitive optical coherence tomography.

Authors:  Guangying Guan; Roberto Reif; Zhihong Huang; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2011-12       Impact factor: 3.170

2.  Water permeability of the mammalian cochlea: functional features of an aquaporin-facilitated water shunt at the perilymph-endolymph barrier.

Authors:  A Eckhard; M Müller; A Salt; J Smolders; H Rask-Andersen; H Löwenheim
Journal:  Pflugers Arch       Date:  2014-01-03       Impact factor: 3.657

3.  Microneedle-mediated intrascleral delivery of in situ forming thermoresponsive implants for sustained ocular drug delivery.

Authors:  Raghu Raj Singh Thakur; Steven J Fallows; Hannah L McMillan; Ryan F Donnelly; David S Jones
Journal:  J Pharm Pharmacol       Date:  2013-10-16       Impact factor: 3.765

4.  Imaging depth extension of optical coherence tomography in rabbit eyes using optical clearing agents.

Authors:  Ruiming Kong; Wenjuan Wu; Rui Qiu; Lei Gao; Fengxian Du; Ailin Liu; Xuan Cai; Cuixia Dai
Journal:  Exp Biol Med (Maywood)       Date:  2020-08-13

5.  Permeation of human plasma lipoproteins in human carotid endarterectomy tissues: measurement by optical coherence tomography.

Authors:  M G Ghosn; M Mashiatulla; S H Syed; M A Mohamed; K V Larin; J D Morrisett
Journal:  J Lipid Res       Date:  2011-04-20       Impact factor: 5.922

6.  Time dependent changes in aortic tissue during cold storage in physiological solution.

Authors:  M G Ghosn; M Mashiatulla; M A Mohamed; S Syed; F Castro-Chavez; J D Morrisett; K V Larin
Journal:  Biochim Biophys Acta       Date:  2011-02-21

Review 7.  Biomedical Imaging in Implantable Drug Delivery Systems.

Authors:  Haoyan Zhou; Christopher Hernandez; Monika Goss; Anna Gawlik; Agata A Exner
Journal:  Curr Drug Targets       Date:  2015       Impact factor: 3.465

8.  Effect of temperature on permeation of low-density lipoprotein particles through human carotid artery tissues.

Authors:  Mohamad G Ghosn; Michael Leba; Astha Vijayananda; Panteha Rezaee; Joel D Morrisett; Kirill V Larin
Journal:  J Biophotonics       Date:  2009-10       Impact factor: 3.207

9.  Monitoring of glucose permeability in monkey skin in vivo using Optical Coherence Tomography.

Authors:  Mohamad G Ghosn; Narendran Sudheendran; Mark Wendt; Adrian Glasser; Valery V Tuchin; Kirill V Larin
Journal:  J Biophotonics       Date:  2010-01       Impact factor: 3.207

10.  Recent progress in tissue optical clearing.

Authors:  Dan Zhu; Kirill V Larin; Qingming Luo; Valery V Tuchin
Journal:  Laser Photon Rev       Date:  2013-02-05       Impact factor: 13.138

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.