Literature DB >> 17521802

Statistical segmentation of surgical instruments in 3-D ultrasound images.

Marius George Linguraru1, Nikolay V Vasilyev, Pedro J Del Nido, Robert D Howe.   

Abstract

The recent development of real-time 3-D ultrasound (US) enables intracardiac beating-heart procedures, but the distorted appearance of surgical instruments is a major challenge to surgeons. In addition, tissue and instruments have similar gray levels in US images and the interface between instruments and tissue is poorly defined. We present an algorithm that automatically estimates instrument location in intracardiac procedures. Expert-segmented images are used to initialize the statistical distributions of blood, tissue and instruments. Voxels are labeled through an iterative expectation-maximization algorithm using information from the neighboring voxels through a smoothing kernel. Once the three classes of voxels are separated, additional neighboring information is combined with the known shape characteristics of instruments to correct for misclassifications. We analyze the major axis of segmented data through their principal components and refine the results by a watershed transform, which corrects the results at the contact between instrument and tissue. We present results on 3-D in-vitro data from a tank trial and 3-D in-vivo data from cardiac interventions on porcine beating hearts, using instruments of four types of materials. The comparison of algorithm results to expert-annotated images shows the correct segmentation and position of the instrument shaft.

Mesh:

Year:  2007        PMID: 17521802      PMCID: PMC2597268          DOI: 10.1016/j.ultrasmedbio.2007.03.003

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  13 in total

1.  Segmentation of ultrasound B-mode images with intensity inhomogeneity correction.

Authors:  Guofang Xiao; Michael Brady; J Alison Noble; Yongyue Zhang
Journal:  IEEE Trans Med Imaging       Date:  2002-01       Impact factor: 10.048

2.  In-vitro visualization of biopsy needles with ultrasound: a comparative study of standard and echogenic needles using an ultrasound phantom.

Authors:  R E Hopkins; M Bradley
Journal:  Clin Radiol       Date:  2001-06       Impact factor: 2.350

3.  Combinative multi-scale level set framework for echocardiographic image segmentation.

Authors:  Ning Lin; Weichuan Yu; James S Duncan
Journal:  Med Image Anal       Date:  2003-12       Impact factor: 8.545

4.  Changes in ultrasonographic echogenicity and visibility of needles with changes in angles of insonation.

Authors:  Kremer Nichols; Lonnie B Wright; Trey Spencer; William C Culp
Journal:  J Vasc Interv Radiol       Date:  2003-12       Impact factor: 3.464

5.  Feasibility of off-pump ASD closure using real-time 3-D echocardiography.

Authors:  Stephen W Downing; William R Herzog; Michael C McElroy; Timothy B Gilbert
Journal:  Heart Surg Forum       Date:  2002       Impact factor: 0.676

6.  3-D active appearance models: segmentation of cardiac MR and ultrasound images.

Authors:  Steven C Mitchell; Johan G Bosch; Boudewijn P F Lelieveldt; Rob J van der Geest; Johan H C Reiber; Milan Sonka
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

7.  A level set approach for shape-driven segmentation and tracking of the left ventricle.

Authors:  Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2003-06       Impact factor: 10.048

8.  Improved watershed transform for medical image segmentation using prior information.

Authors:  V Grau; A U J Mewes; M Alcañiz; R Kikinis; S K Warfield
Journal:  IEEE Trans Med Imaging       Date:  2004-04       Impact factor: 10.048

9.  Real-time three-dimensional ultrasound for guiding surgical tasks.

Authors:  Jeremy W Cannon; Jeffrey A Stoll; Ivan S Salgo; Heather B Knowles; Robert D Howe; Pierre E Dupont; Gerald R Marx; Pedro J del Nido
Journal:  Comput Aided Surg       Date:  2003

10.  Three-dimensional echo-guided beating heart surgery without cardiopulmonary bypass: atrial septal defect closure in a swine model.

Authors:  Yoshihiro Suematsu; Joseph F Martinez; Benjamin K Wolf; Gerald R Marx; Jeffrey A Stoll; Pierre E DuPont; Robert D Howe; John K Triedman; Pedro J del Nido
Journal:  J Thorac Cardiovasc Surg       Date:  2005-10-13       Impact factor: 5.209

View more
  3 in total

1.  A probabilistic framework for freehand 3D ultrasound reconstruction applied to catheter ablation guidance in the left atrium.

Authors:  Aditya B Koolwal; Federico Barbagli; Christopher R Carlson; David H Liang
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-06-04       Impact factor: 2.924

2.  Fast block flow tracking of atrial septal defects in 4D echocardiography.

Authors:  Marius George Linguraru; Nikolay V Vasilyev; Gerald R Marx; Wayne Tworetzky; Pedro J Del Nido; Robert D Howe
Journal:  Med Image Anal       Date:  2008-01-17       Impact factor: 8.545

3.  3D-2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch.

Authors:  T De Silva; A Uneri; M D Ketcha; S Reaungamornrat; G Kleinszig; S Vogt; N Aygun; S-F Lo; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-18       Impact factor: 3.609

  3 in total